Description
Reliable Sterilight Replacement Lamp for Optimal UV Water Treatment Performance
When your water purification system needs consistent UV light to effectively neutralize contaminants, the S410RL-HO Sterilight Replacement Lamp delivers dependable performance. Designed specifically for Sterilight SPV-8 and SP410-HO systems, this ultraviolet replacement lamp ensures your water treatment setup operates safely and efficiently. With quality engineering tailored for UV equipment replacements, it helps maintain clean, clear water without compromising system integrity.
Key Benefits
- Ensures consistent UV disinfection to protect your water supply
- Compatible with Sterilight SPV-8 and SP410-HO systems for hassle-free replacement
- Extends the lifespan of your water treatment equipment by maintaining optimal UV output
- Easy to install, minimizing downtime and maintaining system efficiency
- Supports safe and reliable operation of your ultraviolet water purification setup
- Engineered for durability to withstand regular use in water treatment environments
How It Works
The S410RL-HO replacement lamp emits ultraviolet light at a wavelength designed to deactivate harmful microorganisms in your water supply. Installed inside the Sterilight UV chamber, this lamp exposes water flowing through the system to powerful UV rays, disrupting the DNA of bacteria, viruses, and other pathogens. This process helps ensure that the water leaving your treatment system is significantly safer and clearer.
By fitting perfectly into specific Sterilight models like the SPV-8 or SP410-HO, the lamp maintains optimal positioning and intensity, allowing your ultraviolet equipment to function at peak performance without interruption.
What to Expect
Once installed, the S410RL-HO lamp immediately restores your UV system’s ability to disinfect water effectively. Over the first few days, you’ll notice your water maintaining clarity and safety as the lamp reaches its full operating intensity. In the longer term, regular replacement of this lamp ensures your ultraviolet water equipment remains reliable, preventing microbial buildup and system inefficiencies.
Routine maintenance involves checking lamp hours and replacing the lamp accordingly to avoid diminished UV output and to sustain system performance.
What’s Inside
- UV Quartz Sleeve – Protects the lamp while allowing optimal UV transmission
- High-Output UV Lamp – Provides the necessary ultraviolet energy for water disinfection
- Precision Filament – Ensures consistent light emission and lamp longevity
- Standardized Base – Allows secure, easy installation into Sterilight SPV-8 and SP410-HO systems
How to Use
- Turn off the power to your Sterilight UV system and unplug it for safety.
- Carefully remove the existing lamp by gently pulling it out of the quartz sleeve.
- Inspect and clean the quartz sleeve if necessary, removing any buildup or deposits.
- Handle the new S410RL-HO lamp by its base or use a clean cloth to avoid fingerprints on the glass.
- Insert the replacement lamp into the quartz sleeve, ensuring a secure fit.
- Restore power to the UV system and verify that the lamp ignites and operates correctly.
- Reset any lamp hour counters or maintenance reminders as per your system’s instructions.
Why Choose This Product
- Manufactured to high standards ensuring durability and consistent UV output
- Trusted by water treatment professionals and compatible with popular Sterilight models
- Supports effective ultraviolet sanitation within your water treatment system
- Backed by Water Softener Plus’ commitment to quality and customer satisfaction
- Designed to fit seamlessly into your existing equipment for quick, hassle-free replacement
FAQ & Safety
Is this lamp compatible with all Sterilight UV systems?
This replacement lamp is specifically designed for the SPV-8 and SP410-HO models. Please verify your system model before purchasing.
How often should I replace the UV lamp?
Typically, UV lamps should be replaced every 9,000 to 12,000 hours of operation to maintain effective disinfection.
Can I touch the glass part of the lamp during installation?
Avoid touching the glass with bare hands, as oils can damage the lamp; use gloves or a clean cloth.
What maintenance is required after installing the lamp?
Regularly inspect and clean the quartz sleeve and monitor lamp usage hours for timely replacement.
Are there any special safety precautions?
Always disconnect power before servicing the UV system and handle lamps carefully to avoid breakage.
Upgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.
Overview
- ? U.S.-based support and expert assistance
- ?? Built with trusted Pentair & Fleck components
- ?? Ships nationwide - freight-safe packaging
- ?? Ideal for residential and light-commercial systems
Specs (Typical)
| Max Operating Pressure | 125 psi |
|---|---|
| Max Water Temp | 100 ?F |
| Electrical | 120 V AC |
| Flow Range | 5-45 GPM (model dependent) |
Related: Control Valves . Parts . Get sizing help

