HF1-4040, TLC Membrane, Low Energy, 4x40, 150 PSI, 200379


Price:
Sale price$587.90

Description

HF1-4040 TLC Membrane: Efficient Low-Energy Commercial RO Solution for Consistent Water Purity

The HF1-4040 TLC Membrane from Water Softener Plus sets a new standard in commercial reverse osmosis (RO) components by delivering high performance at reduced energy consumption. Designed for systems operating up to 150 PSI, this low-energy membrane tackles the core challenge of balancing water purification efficiency with operational cost savings. If you need a reliable membrane that enhances water treatment system longevity and output, this model is tailored to meet those demands.

Key Benefits

  • Reduces energy consumption for cost-effective water purification
  • Delivers consistent water quality with high salt rejection rates
  • Supports high-pressure system operations up to 150 PSI for versatility
  • Enhances system durability with a robust membrane structure
  • Compatible with standard 4x40 inch commercial RO housings to simplify upgrades
  • Minimizes downtime with reliable, long-lasting filtration performance

How It Works

The HF1-4040 TLC Membrane functions as the core filtration element within a commercial reverse osmosis system. Water under pressure is forced through the semi-permeable membrane, which selectively removes dissolved salts, impurities, and contaminants. This membrane’s low-energy design means it requires less pressure to achieve the same purification, reducing overall system energy needs.

By operating at pressures up to 150 PSI, it maintains effective filtration while integrating seamlessly into existing RO setups. The membrane’s structure ensures stable flow rates and prevents fouling, keeping your water treatment system running smoothly and efficiently.

What to Expect

Once installed, you’ll notice an immediate improvement in water purity and system efficiency. The membrane starts filtering effectively from day one, providing clean, low-TDS water suitable for commercial applications. Over the first few weeks, your system may experience steady performance stabilization as the membrane conditions to your specific water source.

Long-term, this membrane requires minimal maintenance and offers consistent output, helping avoid costly replacements. Regular system monitoring and appropriate pre-treatment will extend membrane life and maintain optimal performance over time.

What’s Inside

  • Low-Energy Thin Film Composite (TFC) Membrane – enables high rejection rates with reduced pressure requirements
  • Durable Polyamide Layer – provides chemical resistance and supports long operational life
  • Robust Membrane Housing – designed to withstand pressures up to 150 PSI ensuring safety and reliability
  • Standard 4x40 Inch Form Factor – allows easy integration with most commercial RO systems

How to Use

  1. Shut off the water supply and relieve system pressure before removal of the old membrane.
  2. Open the RO membrane housing and carefully remove the existing membrane.
  3. Insert the HF1-4040 TLC Membrane into the housing, ensuring correct orientation and secure placement.
  4. Close and tighten the membrane housing securely to prevent leaks.
  5. Turn the water supply back on and check for leaks or irregular flow.
  6. Flush the membrane according to your system’s instructions to condition it before regular use.
  7. Monitor system pressure and water quality regularly to ensure optimal performance.

Why Choose This Product

  • Engineered with premium materials for durability and long-lasting service life
  • Produced by Water Softener Plus, a trusted name in commercial water treatment solutions
  • Designed specifically for commercial RO systems requiring reliable low-energy membranes
  • Compatible with a broad range of system pressures and configurations
  • Offers a cost-effective balance of performance and energy savings

FAQ & Safety

Is this membrane compatible with all 4x40 inch RO housings?
Yes, the HF1-4040 TLC Membrane is designed to fit standard 4x40 inch commercial RO housings used widely in water treatment systems.

What maintenance does this membrane require?
Regular monitoring of feed water quality and periodic cleaning or replacement based on system performance will keep the membrane functioning optimally.

Can it handle feed water pressures above 150 PSI?
No, this membrane is rated for a maximum operating pressure of 150 PSI; exceeding this may damage the membrane or reduce its lifespan.

How often should the membrane be replaced?
Replacement frequency depends on water quality and system use, but typically every 2-3 years with proper maintenance.

Is special pre-treatment needed before installation?
Pre-treatment to remove sediment and chlorine is recommended to protect the membrane and maximize its durability.

Does this membrane reduce energy consumption compared to standard membranes?
Yes, its low-energy design means it operates efficiently at lower pressures, reducing overall system energy costs.

Upgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.

Overview

  • ? U.S.-based support and expert assistance
  • ?? Built with trusted Pentair & Fleck components
  • ?? Ships nationwide - freight-safe packaging
  • ?? Ideal for residential and light-commercial systems

Specs (Typical)

Max Operating Pressure125 psi
Max Water Temp100 ?F
Electrical120 V AC
Flow Range5-45 GPM (model dependent)

Related: Control Valves . Parts . Get sizing help

Free Manual PDF

You may also like

Recently viewed