Description
Autotrol 255/460i
Pentair Autotrol 255 Valve with 460i Electronic Demand Controller
The Pentair Autotrol 255 Valve with 460i Electronic Demand Controller is a water softening system component designed to efficiently manage and control the water softening process.
Components:
-
Autotrol 255 Valve:
- The valve controls the flow of water through the water softening system.
- It is responsible for directing water through the resin tank for softening and managing the regeneration cycle to refresh the resin.
-
460i Electronic Demand Controller:
- This is an electronic control unit that automates the operation of the water softener.
- It monitors water usage and initiates the regeneration cycle as needed, ensuring that the system operates efficiently and provides a consistent supply of soft water.
Features:
-
Automated Operation:
- The 460i Electronic Demand Controller automates the water softening process, eliminating the need for manual intervention.
- It ensures that the system regenerates as needed based on water usage.
-
Efficiency:
- The system operates efficiently, minimizing water and salt usage by regenerating only when necessary.
- This leads to cost savings and environmental benefits.
-
Reliability:
- The combination of the Autotrol 255 Valve and 460i Electronic Demand Controller ensures reliable and consistent operation.
- Users can trust the system to provide soft water whenever needed.
Benefits:
-
Consistent Soft Water Supply:
- The system ensures a continuous supply of soft water, improving water quality for various household uses.
-
Ease of Use:
- The electronic demand controller makes it easy to manage the water softener, with minimal user intervention required.
-
Cost and Resource Efficiency:
- By regenerating only when needed, the system conserves water and salt, leading to cost savings and reduced environmental impact
The Pentair Autotrol 255 Valve with 460i Electronic Demand Controller is suitable for residential and small commercial applications where efficient and reliable water softening is required.
For the most accurate and detailed information about this system, including specifications, installation instructions, and operating guidelines, it is essential to refer to the manufacturer's official documentation or contact Pentair directly.
PRODUCT INFO
Autotrol 255/460i Parts:
-
Control Valve (Autotrol 255):
- Valve Body: The main component that directs water flow through the system.
- Internal Components: May include pistons, seals, and spacers that facilitate the movement of water and control the regeneration cycle.
- Inlet/Outlet Ports: Connections for the water supply line and the line leading to the home's plumbing system.
-
Electronic Demand Controller (460i):
- Electronic Control Board: The brain of the controller, which manages the operation of the water softener based on water usage and other parameters.
- User Interface: May include buttons and a display for programming and monitoring the system.
- Sensors: Monitor water flow and usage to determine when regeneration is needed.
-
Bypass Valve:
- Allows water to bypass the softener, useful during maintenance or installation.
-
Drain Line Connection:
- A port for connecting a drain line to carry water to a drain during the regeneration cycle.
-
Brine Line Connection:
- A connection for a line leading to the brine tank, which holds salt for use during the regeneration cycle.
-
Power Supply:
- Connects the electronic demand controller to an electrical outlet for power.
Additional Information:
- The Autotrol 255 valve is responsible for controlling the flow of water through the water softening system and managing the regeneration cycle.
- The 460i Electronic Demand Controller automates the operation of the system, ensuring it regenerates as needed based on water usage.
- Together, these components ensure the efficient and reliable operation of the water softener, providing a consistent supply of soft water for the household.
For the most accurate and detailed information about the parts of the Autotrol 255/460i, including diagrams, specifications, and part numbers, it is essential to refer to the manufacturer's official documentation or contact the manufacturer directly.
Pentair Autotrol 460i Parts:
-
Electronic Control Board:
- This is the central component that manages the operation of the water softener.
- It monitors water usage and controls the regeneration cycle based on the settings programmed by the user.
-
User Interface:
- The user interface may include buttons, dials, or a digital display.
- It allows users to program the water softener settings, including the regeneration schedule and water hardness level.
-
Sensors:
- Sensors monitor the flow of water through the system.
- They send data to the control board to help it determine when regeneration is needed.
-
Wiring Harness:
- The wiring harness connects the electronic components and provides power to the system.
-
Connectors:
- Connectors allow the 460i to be attached to the water softener valve and other components.
- They ensure secure and reliable connections for optimal operation.
-
Power Supply:
- The power supply provides electrical power to the electronic components.
- It may include a power cord and plug for connection to a standard electrical outlet.
Additional Information:
- The Autotrol 460i Electronic Demand Controller is designed to automate the operation of a water softener, ensuring it works efficiently and effectively.
- It monitors water usage and initiates the regeneration cycle as needed, helping to conserve water and salt while ensuring a consistent supply of soft water.
- Proper installation and programming are essential for optimal performance