Description
Autotrol Backwash Assembly for 10 Tanks – Ensure Efficient Water Softener Performance
When it comes to maintaining optimal water treatment, the AT1000212 Autotrol Backwash Assembly stands out as a reliable solution designed specifically for 10-tank systems. This essential component addresses common backwash inefficiencies, helping prevent sediment buildup and improving the overall lifespan of your Autotrol valve parts. Engineered for seamless integration, it offers dependable performance for your water softener setup.
Key Benefits
- Enhances backwash efficiency to maintain clean media and effective ion exchange
- Protects your water softener system from sediment and debris buildup
- Ensures consistent water flow and pressure during regeneration cycles
- Durable construction designed to withstand regular system use and water pressure
- Compatible with standard 10-tank Autotrol valve setups for easy replacement
- Reduces maintenance frequency by improving system reliability
How It Works
The AT1000212 backwash assembly functions as a critical part of your water softener’s regeneration process. During backwash cycles, it directs water flow through the tank media to flush out trapped sediment and contaminants effectively. This helps restore the media’s capacity to soften water by removing accumulated debris, ensuring your system operates at peak efficiency.
By integrating seamlessly with Autotrol valve parts, this assembly coordinates the timing and flow of backwash water through multiple tanks, optimizing the cleaning process and protecting your system from premature wear.
What to Expect
Once installed, you’ll notice improved backwash performance with cleaner water output and more consistent regeneration cycles. In the first few days, the system will efficiently flush out any residual sediment, contributing to smoother water softening operations. Over time, this assembly helps maintain the integrity of your tanks and media, reducing the need for frequent manual cleaning or repairs.
With proper installation, expect long-term durability and fewer interruptions in your water treatment routine, supporting reliable water quality for your home or facility.
What’s Inside
- Backwash Assembly Housing – Provides a sturdy structure for directing water flow during backwash cycles
- Flow Control Valve – Regulates water pressure and ensures optimal flow rate for effective sediment flushing
- Seals and Gaskets – Prevent leaks and maintain system integrity under pressure
- Connection Ports – Designed for secure attachment to 10-tank Autotrol valve systems, enabling easy integration
How to Use
- Turn off the water supply and relieve system pressure before starting installation.
- Remove the existing backwash assembly from your Autotrol valve setup carefully.
- Inspect connection points for debris or damage and clean if necessary.
- Install the AT1000212 backwash assembly by aligning and securing all connection ports firmly.
- Check all seals and gaskets to ensure a tight fit and prevent leaks.
- Restore water supply and monitor the first backwash cycle to confirm proper operation.
- Schedule regular system checks to maintain peak performance and address any wear.
Why Choose This Product
- Manufactured with high-quality materials designed for durability and long-term use
- Backed by Water Softener Plus, a trusted name in water treatment components
- Specifically engineered to fit 10-tank Autotrol valve systems, ensuring compatibility and ease of installation
- Designed to improve system efficiency and reduce maintenance needs, saving time and costs
FAQ & Safety
Is this backwash assembly compatible with all Autotrol valves?
It is designed specifically for 10-tank Autotrol valve systems; compatibility with other models should be confirmed before purchase.
How often should I replace the backwash assembly?
Replacement frequency depends on water quality and usage, but regular inspections every 1-2 years are recommended to ensure optimal performance.
Can I install this assembly myself?
Yes, with basic plumbing knowledge and by following the installation steps carefully, this assembly can be replaced safely.
What maintenance does this component require?
Periodic checks for leaks and wear are advised, along with cleaning the system media during backwash cycles.
Does it handle high water pressure?
The assembly is built to withstand typical residential and commercial water pressures but verify your system specifications to avoid exceeding limits.
Upgrade your system reliability today—add this Autotrol Backwash Assembly to your cart and keep your water flowing clean and consistent for years to come.
Overview
- ? U.S.-based support and expert assistance
- ?? Built with trusted Pentair & Fleck components
- ?? Ships nationwide - freight-safe packaging
- ?? Ideal for residential and light-commercial systems
Specs (Typical)
| Max Operating Pressure | 125 psi |
|---|---|
| Max Water Temp | 100 ?F |
| Electrical | 120 V AC |
| Flow Range | 5-45 GPM (model dependent) |
Related: Control Valves . Parts . Get sizing help

