VOC Concerns in Union County: Understanding VOCs in Elizabeth City and Monroe Twp. Water

Fleck VOCs & Industrial Chemicals Filter

$1,314.67

Fleck VOCs & Industrial Chemicals Filter

View full details

✓ Free shipping in the USA  ·  ✓ 90-day returns  ·  ✓ Secure checkout

Fleck VOCs & Industrial Chemicals Filter

Fleck VOCs & Industrial Chemicals Filter

Buy Now

View full details

Understanding VOCs and Their Routes of Exposure

VOCs include compounds like 1,1-dichloroethane, chloromethane, and halon 1011

These volatile organic compounds (VOCs) are solvent compounds that can evaporate into air and contribute to exposure through inhalation as well as ingestion. Activities such as showering and dishwashing can release VOCs into indoor air, increasing inhalation. Drinking water also contributes to exposure but is just one route.

Not all VOCs have federal maximum contaminant levels (MCLs)

For the NJ American Water Co. - Raritan system serving Union County areas including Elizabeth City and Monroe Township, none of the VOCs detected in federal occurrence monitoring had applicable MCLs during 2013-2015. Detection is a measurement, not a violation.

Factors Affecting VOC Presence in Large or Seasonal Households

Household water use patterns influence VOC levels in tap water airspace

Larger households or those with higher water use tend to renew water volume more often, potentially reducing stagnation that allows VOC volatilization. Conversely, seasonal properties with lower water use may experience longer retention times, affecting VOC presence.

Equipment failure can increase VOC exposure

Failure of existing water treatment equipment designed to reduce volatile organics means VOCs present in supplied water could be more noticeable in household water.

How the Fleck VOCs & Industrial Chemicals Filter Addresses VOCs

The Fleck System targets VOCs and industrial chemicals in residential water

This filter employs media and technology formulated to remove a broad range of volatile organic compounds and solvent compounds documented in municipal water monitoring. It ships ready to configure for direct consumer use, providing a way to reduce VOC levels at the point of water entry to the home.

Reduction of VOCs improves both inhalation and ingestion exposure routes

Lowering VOC concentrations in your water supply reduces their evaporation during household water use and limits direct intake when drinking or cooking, addressing the main exposure pathways.

Sources and Entry Points of VOCs in Union County Water

Surface water source is the NOAA record for the Raritan system

Union County's public water system is supplied by surface waters. VOCs may enter these sources from industrial activities, runoff, or atmospheric deposition, then pass into the distribution system.

Distribution system monitoring records low VOC detections

Data from 2013 to 2015 show mostly no detections above reporting levels for listed VOCs. Only halon 1011 was once recorded slightly above its detection limit, though with no health-based violation noted.

Preparing for VOC Testing and Treatment Discussions

Note system service area and source type

Document that your household is served by NJ American Water Co. - Raritan, which uses surface water sources.

Collect information on prior equipment performance and failure

Record when and how your previous VOC treatment equipment failed to help pinpoint potential VOC exposure changes.

Identify household water use patterns

Determine if your residence is a large household, second home, or seasonal property, as these factors influence VOC presence and treatment needs.

Ruling Out Causes: From Simple Steps to Testing

Step 1: Check for recent plumbing changes or stagnation

Long water stagnation in pipes can increase volatilization without changing water source VOC levels.

Step 2: Obtain a water test specific to VOCs

Because regional data cannot specify your home's VOC levels, a focused laboratory test for VOCs in your tap water is necessary to know your exact situation.

Step 3: Consider deploying a Fleck VOCs & Industrial Chemicals Filter

If testing confirms VOC presence or your household is sensitive to volatile organics, this filter provides a documented solution shipping ready to configure.

In summary, regional public water system data for Union County shows very low VOC detections with no health-based violations, but your household's water may differ especially after treatment equipment failure. By understanding exposure routes, household use impacts, and treatment options like the Fleck VOCs & Industrial Chemicals Filter, you can take informed steps to manage VOCs effectively.

Where this information comes from

Source: EPA SDWIS public water system record. Sampled 2015-12-07. These figures describe the public water system's record, not the plumbing inside any individual building.

On record: EPA UCMR3 monitoring (2013-2015) for NJ American Water Co. - Raritan (NJ2004002), NJ: 256 results across 7 listed contaminants, 1 detections above the reporting level; no federal MCL for these UCMR-listed VOCs