C-Series Perchlorate Filter

C-Series Perchlorate Filter

Request a Quote

View full details

First Fixtures and Appliances Affected by Perchlorate in Household Water

Perchlorate is a chemical that can be found in groundwater sources, such as those supplying the Memphis Light, Gas, & Water public water system in Shelby County. While government sampling from 2002 in this system found no perchlorate above the reporting level of 4.0 micrograms per liter, understanding which fixtures and appliances would be influenced if perchlorate were present is useful for homeowners considering treatment. Appliances and plumbing fixtures that directly use untreated water, such as ice makers, drinking fountains, and any point-of-use water dispensers, would be the first to show any impact from perchlorate in the water. Since perchlorate can interfere with thyroid function if ingested in higher amounts, attention to these outlets is important for household health management decisions.

Distinguishing Perchlorate From Similar Water Quality Concerns

Perchlorate is often confused with other water quality issues, such as nitrate contamination or salt-related water problems, but it differs significantly in behavior and treatment approach. Unlike nitrate, which originates mainly from agricultural runoff and has explicit drinking water limits, perchlorate is an industrial chemical that does not have a federal maximum contaminant level (MCL) but is monitored due to potential health effects. Perchlorate does not impart taste or odor and will not cause staining or scaling like some other dissolved solids might. Recognizing this distinction helps avoid misdiagnosis of water issues and directs attention toward specific testing and treatment for perchlorate if concerns arise.

Interpreting Memphis Water System’s Perchlorate Measurements and Federal Standards

The EPA's Unregulated Contaminant Monitoring Rule (UCMR) results for Memphis Light, Gas, & Water from 2002 show no perchlorate detection above the reporting level of 4.0 µg/L. This reporting level is the minimum concentration the sampling methods could reliably identify, but a nondetection does not guarantee zero perchlorate in any individual household’s water. Moreover, perchlorate currently has no federal MCL, which means the EPA has not set a legally enforceable limit for drinking water. The absence of detections above the reporting level in extensive system-wide sampling indicates perchlorate is not a widespread issue in the public supply but does not replace the need for private water testing in homes relying on private wells or other nonpublic sources.

Assessing Treatment Capacity Relative to Household Daily Water Demand

When selecting treatment equipment to address perchlorate, households in Shelby County should consider the volume of water used daily. Residential water demand impacts the capacity required from a perchlorate reduction system. For example, a family’s consumption, peak usage times, and specific points of use needing treatment influence sizing decisions. The C-Series Perchlorate Filter ships ready to configure for household water conditions, offering scalable treatment capacity based on water volume. Assessing your daily water use provides a baseline to match system capability with household needs, ensuring effective perchlorate reduction without over- or undersizing equipment.

Comparing Shelby County’s Perchlorate Record With Neighboring Areas

The Memphis Light, Gas, & Water system serves over 650,000 people in Shelby County, drawing from groundwater sources that have been monitored for perchlorate. Comparisons to adjacent counties require looking at similar public water system records to understand local variations. Differences in perchlorate results may arise from variations in industrial activity, groundwater flow patterns, and well depth. While Shelby County’s public water system data shows no perchlorate detected above reporting levels, neighboring areas could have different findings, but these regional distinctions do not predict individual household water quality without specific testing.

Sample Size and Well Data Behind Shelby County’s Perchlorate Figures

The perchlorate results for Memphis Light, Gas, & Water are based on 20 samples collected between July and December 2002 from multiple wells serving the public system. This sample size covers a large interconnected supply serving over 255,000 service connections. While 20 samples provide a representative snapshot of system-wide water quality at that time, it is a limited data set when considering individual household water sources. Small sample sizes mean that while the public water system records show no perchlorate detection above reporting level, private wells should be individually tested for accurate current conditions.

Memphis Light, Gas, & Water’s public water system record for perchlorate reflects monitoring data for the community water supply in Shelby County from 2002, sourced from groundwater. The EPA’s public database provides detailed system monitoring reports for confirmation and further research.

Where this information comes from

Source: EPA SDWIS public water system record. Sampled 2002-12-18. These figures describe the public water system's record, not the plumbing inside any individual building.

On record: EPA UCMR1 monitoring (2001-2005) for MEMPHIS LIGHT, GAS, & WATER (TN0000450), TN: 20 results across 1 listed contaminants, 0 detections above the reporting level; nothing detected above the method reporting level

Newsletter

A short sentence describing what someone will receive by subscribing