C-Series 1,2,3-TCP Filter

C-Series 1,2,3-TCP Filter

Request a Quote

View full details

The water delivered to homes in Puerto Rico often originates from local aquifers or surface water sources that undergo treatment before reaching taps. The Ponce Urbano public water system serves numerous connections within the region, ensuring compliance with federal health-based standards. The Environmental Protection Agency (EPA) has conducted detailed sampling in this system, including monitoring for unregulated contaminants such as 1,2,3-trichloropropane (1,2,3-TCP), a chlorinated solvent known to be persistent in water.

Why does 1,2,3-trichloropropane resist air stripping, and what does that mean for treatment choice?

1,2,3-TCP is a chlorinated solvent with chemical properties that make it resistant to removal by air stripping—a process effective for volatile organic compounds. This resistance stems from its relatively low volatility and chemical stability, causing it to remain dissolved in water through treatment. Because of this, homeowners and public water systems relying solely on air stripping will not effectively reduce or remove TCP from water. Instead, alternative technologies that rely on adsorption or advanced filtration approaches are necessary to address this constituent.

Why does granular activated carbon contact time matter more for TCP than taste?

Granular activated carbon (GAC) filtration is a common treatment method that can adsorb many organic contaminants, including TCP. However, the effectiveness of GAC against TCP depends heavily on the contact time—the duration water stays in contact with the carbon bed. Deeper carbon beds provide longer contact time, which is crucial for adsorbing the less volatile and more persistent TCP molecules. This is different from treatments optimized solely for aesthetic factors like taste or odor, which may require less contact time.

What household or facility symptoms point to 1,2,3-TCP, and which do not?

Unlike contaminants that cause immediate taste or odor issues, 1,2,3-TCP does not usually produce noticeable changes in water’s appearance, smell, or flavor. Households dealing with TCP presence are unlikely to observe typical sensory symptoms. This means that absence of taste or odor issues does not guarantee the absence of TCP. Conversely, any off-tastes or odors more commonly relate to other water quality factors and not TCP. Detecting TCP requires specific chemical testing rather than relying on sensory indicators.

What does a certified laboratory test for 1,2,3-trichloropropane report, and how should it be read?

Certified laboratory results measure 1,2,3-TCP concentrations in micrograms per liter (µg/L), also expressed as parts per billion (ppb). For household water, a lab report will specify the value detected or note if it falls below the reporting limit—often set at 0.03 µg/L for this constituent. Such testing is the only way to establish the concentration in your well or tap specifically, as public system averages do not reflect individual household conditions. Knowing this information is important to decide if additional treatment is warranted.

What does the measured range for 1,2,3-TCP in this system mean against the federal standard, and what does it not?

Federal regulations currently do not establish a maximum contaminant level (MCL) for 1,2,3-TCP, meaning there is no legal limit for this constituent in drinking water. The EPA’s Unregulated Contaminant Monitoring Rule (UCMR3) for the Ponce Urbano system showed 56 sampling results with zero detections above the reporting level of 0.03 µg/L. This indicates that 1,2,3-TCP was not observed in these samples, but it does not confirm absence in every individual household. Furthermore, this absence of detection is not classified as a violation or an indication that water is unsafe.

In summary, public water system monitoring in Puerto Rico’s Ponce Urbano area found no detectable 1,2,3-trichloropropane in multiple samples, suggesting low occurrence in the system. However, individual household water can vary, and specific testing is necessary to understand one’s own exposure. When treatment is desired, technologies like the C-Series 1,2,3-TCP Filter ship ready to configure and provide focused reduction of this chlorinated solvent without relying on ineffective air stripping methods.

Where this information comes from

Source: EPA SDWIS public water system record. Sampled 2016-12-04. These figures describe the public water system's record, not the plumbing inside any individual building.

On record: EPA UCMR3 monitoring (2013-2015) for Ponce Urbano (PR0003824), PR: 56 results across 1 listed contaminants, 0 detections above the reporting level; nothing detected above the method reporting level