Interpreting Detected Radon, Median, and Range in Kit Carson County Samples

The US Geological Survey conducted groundwater sampling in Kit Carson County, focusing on aquifer 121OGLL. Four separate wells sampled between 2010 and 2015 showed radon-222 detected in every sample. The median radon concentration was 267.5 pCi/L, with values ranging from 51.0 to 550.0 pCi/L. These results come from wells 141 to 245 feet deep. "Detected" means the instrument measured radon above the reporting limit; it does not indicate contamination or exceed a safety threshold. Median represents the middle measurement when values are ordered, helping to understand typical conditions in the area. The range indicates variability between wells sampled. No federal thresholds for radon in drinking water were exceeded in these samples. These figures describe regional conditions and do not specify radon levels in any particular household well.

How the Fleck System Addresses Radon in Water

The Fleck Radon in Water Filter offers a water treatment technology designed to reduce radon concentrations effectively. It operates by aerating water to release radon gas and then filtering the water to remove any remaining radon and related decay products. This process lowers the radon level before water reaches household taps. The system ships ready to configure, allowing households to manage radon without depending on external services. It treats radon specifically, distinguishing it from general filtration systems.

Understanding Certified Laboratory Radon Test Reports

A certified laboratory test for radon in water will report measured concentrations in picocuries per liter (pCi/L). The report shows numeric values with a detection limit indicating the smallest concentration the lab can reliably measure. Results below this limit are reported as not detected. The report may include quality control information, sampling date, and test method. Reading the report requires noting whether radon was detected and the measured concentration. Such results are specific to the sampled water source and cannot be directly compared to area sampling without recognizing differences in testing date, depth, and method.

Role of Plumbing Material and Age on Radon Water Levels

Plumbing materials and the age of a household’s distribution system do not affect the source concentration of radon but can influence radon levels at the tap. Older plumbing may allow radon to dissipate through leaks or degrade before reaching points of use. Material permeability and joint integrity can alter radon retention. However, plumbing does not create radon; it transports water that may contain radon from the source aquifer. Understanding household plumbing helps interpret radon test results but cannot replace source water testing.

Additional Considerations for Commercial or Industrial Water Users

Commercial and industrial users often require more extensive water quality monitoring, including radon, due to larger volumes and exposure risks. They must consider compliance with workplace air quality regulations, radon off-gassing during water use, and the impact on processes sensitive to radionuclides. While households focus on drinking water safety, commercial operations add layers of occupational and environmental health concerns. Treatment technology selection may differ based on scale and regulatory demands.

What Not to Conclude from Area Radon Data

Area-level sampling data describe conditions across multiple wells in Kit Carson County’s aquifer 121OGLL and do not establish radon concentrations in any individual household water source. Detection of radon in regional samples is not a violation or indication of unsafe water. Absence of measurements above federal action levels in the area means no documented health-based exceedance from these samples, but individual well testing remains essential to ascertain household water quality. Plumbing factors and individual sampling dates further affect results. Area data serve as a guide to the likelihood of radon presence but do not replace specific analytic testing for private use.

Where this information comes from

Source: USGS groundwater sampling. Sampled 2015-08-13. These figures describe groundwater sampled in this area. They are not a test of any individual private well - only a test of that well can establish its own water.

On record: U.S. Geological Survey sampling of Radon-222 in the 121OGLL aquifer (Kit Carson County): 4 results from 4 wells, median 267.5 pCi/L, range 51.0-550.0 pCi/L; none above any federal threshold

The right way to buy a water system: sized to your water, backed for life, free U.S. shipping.
💳 Buy now, pay over time with Shop Pay Installments  ·  🇺🇸 Free U.S. Shipping
  • ✓ 90-Day Money-BackNo restocking fees — return within 90 days.
  • ✓ Manufacturer WarrantyGenuine Fleck · Pentair · VIQUA equipment.
  • ✓ Free Expert SizingTalk to a specialist and buy the right system the first time.
Not sure what you need? Take the 60-second quiz →

Newsletter

A short sentence describing what someone will receive by subscribing