WaterSoftenerPlus

the sulfur eliminator — Installation Guide

Hydrogen sulfide gas in water causes that unmistakable rotten egg smell and can lead to corrosion, staining, and unpleasant taste. The sulfur eliminator is a crucial system designed to remove these contaminants effectively, improving water quality and household comfort. Among the best solutions on the market is the Fleck 120K Twin Tank system, which offers efficient sulfur removal through advanced filtration technology and dual-tank operation for continuous water treatment.

This installation guide will walk you through the necessary steps to properly install the Fleck 120K Twin Tank sulfur eliminator system. It will cover preparation, assembly, plumbing, setup, and essential maintenance tips to ensure optimal performance and longevity.

Understanding the Fleck 120K Twin Tank Sulfur Eliminator System

The Fleck 120K Twin Tank system is a sophisticated sulfur eliminator designed to handle high hydrogen sulfide levels. It uses two tanks filled with catalytic media that oxidizes and filters out sulfur compounds.

  • Twin Tank Design: Offers continuous operation; while one tank regenerates, the other remains in service.
  • Metered Control Valve: The Fleck 9500 valve automates regeneration cycles based on water usage, maximizing efficiency.
  • Media: Specialized catalytic media oxidizes hydrogen sulfide, converting it to harmless sulfur particles that are filtered out.

Proper installation is critical to ensure that the system functions as intended, providing sulfur-free water and protecting plumbing and appliances.

Pre-Installation Preparation

Before beginning installation, careful planning and preparation will save time and prevent errors.

Site Selection

  • Choose a dry, level area near the main water supply line where the system will be installed.
  • Ensure sufficient clearance around the tanks and control valves for maintenance and media replacement.
  • Check for accessibility to a drain line for backwash discharge.
  • Verify power availability for the control valve’s timer and meter.

Required Tools and Materials

  • Pipe cutter or hacksaw
  • Adjustable wrenches and pliers
  • Teflon tape or pipe thread sealant
  • Pipe fittings and connectors appropriate for your plumbing
  • Drain tubing or piping for backwash discharge
  • Bucket for media loading
  • Safety gloves and eye protection

System Inspection

Unpack the Fleck 120K Twin Tank system and inspect all components for damage or defects. Confirm that the two tanks, control valves (Fleck 9500), media, and all fittings are included.

Step-by-Step Installation Process

1. Shut Off Water Supply and Drain Pipes

Before cutting into the water line, shut off the main water supply. Open a faucet downstream to relieve pressure and drain water from the pipes.

2. Position the Twin Tanks

Place the two tanks on the prepared surface in their intended positions. Ensure the control valve connections will align with the plumbing.

3. Install the Control Valves on Tanks

  • Apply Teflon tape to the threaded connections on the tanks.
  • Attach the Fleck 9500 control valves securely to the tanks, ensuring proper alignment.
  • Connect the distributor tubes inside the tanks if they are not pre-installed.

4. Load the Catalytic Media

  • Remove the tank caps or open the top access.
  • Slowly pour the catalytic media into each tank, avoiding dust inhalation.
  • Fill to the recommended level, usually around 50% of tank volume, following the manufacturer’s instructions.
  • Replace the tank caps securely.

5. Connect Plumbing Lines

Cut into the main water line where the system will be installed. Use appropriate fittings to connect the inlet and outlet pipes to the twin tanks in parallel with a bypass valve, if desired, for maintenance convenience.

  • Ensure the water flows through the system in the correct direction as indicated on the control valves.
  • Install a pressure relief valve if required by local regulations.
  • Attach the backwash drain tubing to the drain outlet on the control valves, directing the discharge to a suitable drain.

6. Connect Electrical Power

Plug in or hardwire the Fleck 9500 control valves to a power source. Ensure the connection is safe and complies with electrical codes.

7. Initial System Setup and Programming

  • Turn on the water supply slowly and check for leaks around all connections.
  • Program the Fleck 9500 valve according to your water usage and media regeneration requirements. Key parameters include:
    • Current time and day
    • Regeneration frequency (typically every 3-7 days)
    • Backwash duration and rinse times
    • Meter settings for demand-initiated regeneration
  • Perform a manual regeneration cycle to flush the system and condition the media.

Testing and Commissioning

Once installed and programmed, it is essential to verify that the sulfur eliminator system is functioning correctly.

  • Run water through the system and check for any unusual noises or leaks.
  • Test water for hydrogen sulfide odor at various outlets to confirm sulfur removal.
  • Observe the regeneration cycle to ensure it initiates and completes as programmed.
  • Check the backwash drain flow to verify proper flushing of media.

Maintenance and Troubleshooting Tips

Regular maintenance and prompt troubleshooting will keep the Fleck 120K Twin Tank sulfur eliminator system running efficiently for years.

Routine Maintenance

  • Media Replacement: Over time, the catalytic media will lose effectiveness. Replace media every 3-5 years or as needed based on water quality tests.
  • Valve Inspection: Periodically check the Fleck 9500 control valves for wear, leaks, or malfunction.
  • Cleaning: Clean the brine tank and drain lines to prevent blockages.
  • System Sanitization: Sanitize the tanks annually to prevent bacterial growth.

Common Issues and Solutions

Persistent Sulfur Odor After Installation

  • Ensure the media is properly loaded and not exhausted.
  • Check for bypass leaks or incorrect plumbing connections allowing untreated water through.
  • Verify that regeneration cycles are occurring on schedule.
  • Flush the system manually if odor persists after initial startup.

Water Flow Reduction or Low Pressure

  • Inspect for clogged media or sediment buildup in tanks.
  • Check inlet and outlet screens for debris.
  • Clean or replace control valve components if obstructed.
  • Backwash the system to clear trapped particles.

Control Valve Malfunction

  • Reset the valve controller to default settings and reprogram.
  • Inspect electrical connections and power supply.
  • Replace faulty solenoids or timers if necessary.

Optimizing System Performance

To maximize the efficiency and lifespan of your sulfur eliminator, consider these best practices:

  • Pre-Filtration: Install a sediment filter upstream to remove particulates that can clog media.
  • Regular Water Testing: Test water periodically for hydrogen sulfide levels and other contaminants.
  • Adjust Regeneration Settings: Tailor regeneration frequency and duration to actual water usage to conserve water and salt.
  • Monitor Backwash Drain: Ensure unrestricted flow to prevent system damage.

Conclusion

The Fleck 120K Twin Tank sulfur eliminator system is a powerful and reliable solution for eliminating hydrogen sulfide from water supplies. Following this detailed installation guide will ensure proper setup, enabling continuous, odor-free, and clean water for your home or facility.

Routine maintenance and timely troubleshooting are essential to maintain peak performance. With correct installation and care, the Fleck 120K system will deliver years of effective sulfur removal and improved water quality.

Advanced Programming Tips for the Fleck 9500 Control Valve

The Fleck 9500 control valve, integral to the Fleck 120K Twin Tank sulfur eliminator system, offers versatile programming options to customize operation based on specific water usage patterns and water quality conditions. Understanding these advanced settings can enhance system efficiency and extend media life.

Setting the Metered Regeneration

  • Meter Calibration: The valve uses a water meter to track usage and trigger regeneration. Ensure the meter is calibrated correctly for your flow rate by consulting the valve manual.
  • Regeneration Volume: Program the regeneration volume based on the media capacity and hydrogen sulfide concentration. Overestimating regeneration wastes water and salt, while underestimating can cause odor breakthrough.
  • Backwash and Rinse Times: Adjust these times depending on local water hardness and sediment load. Longer backwash cycles help remove more trapped particles but use more water.

Time Clock Settings

Set the system clock accurately to ensure regeneration initiates at optimal times, typically during low water usage periods (e.g., overnight). This avoids disruption and maximizes efficiency.

Diagnostic Mode

The Fleck 9500 valve includes a diagnostic mode to manually cycle through each phase of regeneration. Use this mode during installation and troubleshooting to verify proper valve operation and to identify any mechanical issues.

Integrating the Sulfur Eliminator with Other Water Treatment Systems

To achieve comprehensive water quality improvement, the sulfur eliminator system can be integrated with other treatment components. Proper sequencing and compatibility are essential for maximum effectiveness.

Pre-Filtration

  • Sediment Filters: Placing a sediment filter upstream prevents large particles from entering the sulfur eliminator, protecting the media and control valve from clogging and damage.
  • Iron Removal Systems: If your water contains iron in addition to hydrogen sulfide, consider an iron filter before or after the sulfur eliminator depending on the iron form (ferrous or ferric).

Water Softening

Hard water can reduce the lifespan of sulfur elimination media and cause scaling in plumbing. Installing a water softener downstream from the sulfur eliminator ensures that softened water reaches faucets and appliances, enhancing comfort and equipment longevity.

Ultraviolet (UV) Disinfection

For water supplies with microbial contamination concerns, integrating a UV disinfection unit after the sulfur eliminator and any softening system provides an effective barrier against bacteria and viruses without introducing chemicals.

Environmental and Operational Considerations

Proper management of backwash discharge and salt usage is important for environmental responsibility and system efficiency.

Backwash Water Disposal

  • Drain Location: Ensure the backwash water is discharged to an appropriate drain or dry well that can handle the volume and composition without causing erosion or contamination.
  • Water Conservation: Adjust backwash duration to the minimum effective time to conserve water.
  • Salt Usage: Use the minimum required salt for regeneration to reduce brine discharge.

Winterization and Freeze Protection

If the sulfur eliminator is installed in an area subject to freezing temperatures, take steps to protect the tanks and control valves:

  • Insulate tanks and pipes with foam sleeves or blankets.
  • Maintain a heated environment or use heat tape on exposed plumbing.
  • Drain the system before extended periods of non-use in freezing conditions.

Frequently Asked Questions (FAQs) About the Sulfur Eliminator Installation

How long does the installation typically take?

Installation time varies depending on plumbing complexity and site preparation but generally takes between 3 to 6 hours for a professional or experienced DIYer.

Can I install the system myself?

Yes, with plumbing knowledge and the right tools, the Fleck 120K Twin Tank sulfur eliminator can be installed by homeowners. However, careful attention to detail is necessary to avoid leaks and ensure proper operation.

How often should the media be replaced?

Media replacement typically ranges from 3 to 5 years, depending on hydrogen sulfide concentration and water usage. Regular water testing can help determine the optimal replacement interval.

What maintenance is required for the control valve?

Control valves require periodic inspection for leaks, cleaning of screens and orifices, and occasional replacement of seals or solenoids to maintain functionality.

Can the system handle high sulfur concentrations?

The Fleck 120K Twin Tank system is designed for moderate to high hydrogen sulfide levels. For extremely high concentrations, pre-treatment or more specialized systems may be necessary.

Conclusion

Installing the Fleck 120K Twin Tank sulfur eliminator system is a reliable and effective way to eliminate hydrogen sulfide from your water supply, enhancing water quality and household comfort. By carefully selecting the installation site, following detailed assembly and plumbing steps, and properly programming the Fleck 9500 control valves, you can ensure continuous sulfur removal with minimal maintenance.

Integrating the sulfur eliminator with complementary water treatment components and adhering to routine maintenance schedules will maximize system longevity and performance. With proper care, this system provides a long-term solution to sulfur-related water issues, delivering fresh, odor-free water throughout your home or facility.

PageID: 13330642011929903157