WaterSoftenerPlus

pentair water softner head — Installation Guide

Installing a Pentair water softener head, specifically the Fleck 5600 SXT Meter Valve, is a critical step in ensuring efficient and reliable water softening for your home or business. This advanced valve controls the regeneration cycle of the water softener, optimizing salt and water usage while maintaining softened water quality. This guide will walk you through the essential steps of installation, setup, and maintenance, helping you achieve optimal performance from your Pentair water softener system.

Understanding the Fleck 5600 SXT Meter Valve

The Fleck 5600 SXT is a widely-used, digital water softener control valve designed to meter water usage and initiate regeneration based on actual consumption. This metered regeneration system prevents unnecessary cycles, saving salt and water while extending the life of your resin bed.

  • Digital Control: The valve features an easy-to-use digital interface for programming and monitoring.
  • Metered Regeneration: Initiates regeneration based on gallons used, improving efficiency.
  • Reliable Components: Durable materials and design ensure long-lasting operation.
  • Compatibility: Fits most Pentair softener tanks and many other brands.

Tools and Materials Required for Installation

Before starting the installation, gather all necessary tools and materials to ensure a smooth process. Having everything on hand will minimize interruptions and help maintain focus on proper installation steps.

  • Fleck 5600 SXT Meter Valve (Pentair Water Filtration FL56-16M-SXT)
  • Water softener resin tank
  • Bypass valve assembly
  • Pipe cutter or hacksaw (for cutting existing water lines)
  • Adjustable wrenches or pipe wrenches
  • Thread seal tape (Teflon tape)
  • Flexible plumbing connectors or appropriate piping (PVC, copper, or PEX)
  • Bucket and towels (for water spills)
  • Level (to ensure valve is mounted straight)
  • Power source (120V outlet for valve timer)

Step-by-Step Installation Process

1. Preparation and Safety Measures

Before installation, turn off the main water supply to the house and relieve pressure by opening a faucet downstream. Shut off the water heater to avoid any accidental damage. Disconnect the existing water softener control valve, if applicable, and drain the resin tank to prevent spills.

Verify that the installation location has adequate space and access to a power outlet for the valve’s timer. Ensure the water softener tank is upright and stable on a flat surface.

2. Installing the Bypass Valve

Attach the bypass valve assembly to the Fleck 5600 SXT meter valve. The bypass valve allows you to isolate the water softener for servicing without shutting off the entire water supply.

  • Wrap the threaded connections with Teflon tape to ensure a watertight seal.
  • Screw the bypass valve onto the valve’s inlet and outlet ports, tightening securely but avoiding overtightening.

Once the bypass valve is installed, connect it to the household water line. Use flexible connectors or appropriate piping to connect the inlet to the main water supply and the outlet to the household plumbing.

3. Attaching the Valve to the Resin Tank

Position the Fleck 5600 SXT valve on top of the resin tank. The valve has a threaded distributor tube that fits inside the tank opening.

  • Ensure the distributor tube is inserted straight to avoid damage to the resin bed.
  • Apply a small amount of silicone lubricant to the tank’s O-ring gasket to ensure a smooth seal.
  • Secure the valve to the tank by tightening the mounting nut by hand, then use an adjustable wrench for an additional quarter turn if necessary.

Double-check that the valve is level and properly seated to prevent leaks.

4. Connecting the Drain Line

The Fleck 5600 SXT valve requires a drain line to expel water and brine during regeneration. Connect a flexible drain hose or PVC pipe to the valve’s drain outlet.

  • Use a hose clamp to secure the drain line to the valve’s drain barb fitting.
  • Run the drain line to an appropriate drain or floor drain, ensuring it is free of kinks or restrictions.
  • Maintain an air gap of at least 1 inch between the end of the drain line and the drain to prevent backflow.
  • A safe elevation drop (typically at least 18 inches below the valve) is necessary to allow proper drain flow.

5. Installing the Brine Tank and Connecting Brine Line

Set up the brine tank adjacent to the resin tank. Fill the brine tank with the appropriate amount of water softener salt and water as per manufacturer instructions.

  • Connect the brine line from the brine tank to the valve’s brine inlet fitting.
  • Ensure the brine line is securely attached and free of leaks.
  • Attach the brine well to the brine tank, if applicable, to protect the brine line from clogging.

6. Electrical Connection and Initial Programming

Plug the Fleck 5600 SXT valve into a grounded 120V electrical outlet. Avoid using extension cords or power strips to ensure consistent power supply.

Once powered, the valve’s digital display will light up, allowing you to program the system parameters:

  • Set the current time of day: Use the up/down buttons to adjust hours and minutes.
  • Set the hardness level: Input the water hardness in grains per gallon (gpg) based on water testing results.
  • Set the salt dosage: Adjust the number of salt units per regeneration cycle.
  • Configure the regeneration cycle time: Typically set to occur at 2:00 AM to minimize water use disruption.

Follow the valve’s user manual for detailed programming instructions or use the on-screen prompts.

Testing and Initial Operation

1. Check for Leaks

Slowly open the main water supply and bypass valve. Inspect all connections for leaks, tightening fittings as necessary. Pay special attention to the bypass valve seals and drain line connection.

2. Initiate a Manual Regeneration Cycle

Manually initiate a regeneration cycle from the valve’s control panel to ensure the system operates correctly:

  • Observe the valve through the backwash, brine draw, and rinse cycles.
  • Verify that water flows properly to the drain during the drain cycle.
  • Check the brine tank for proper salt draw.

After regeneration completes, test the softened water at a faucet to confirm softness.

Routine Maintenance and Troubleshooting

1. Salt Tank Maintenance

Regularly inspect the salt level in the brine tank, maintaining at least half-full to ensure efficient regeneration. Remove any salt bridges or crusts that form on top of the salt.

2. Cleaning the Valve Screen and Injector

Periodically clean the valve’s screen and injector to prevent clogging and ensure proper brine flow:

  • Turn off the water and power supply.
  • Remove the valve cover and locate the screen and injector assembly.
  • Rinse the screen with clean water and use a soft brush to remove debris.
  • Soak the injector in a vinegar or mild acid solution if mineral buildup is present.
  • Reassemble and restore power and water supply.

3. Troubleshooting Common Issues

  • Valve does not advance through cycles: Check power supply and reset the control valve. Inspect for mechanical obstructions or worn gears.
  • Softened water taste or hardness issues: Verify correct programming of hardness and salt dosage. Check for resin exhaustion; resin replacement may be needed after several years.
  • Drain line siphoning or overflowing: Confirm drain line air gap and proper elevation drop. Clear any kinks or blockages in the drain hose.
  • Salt bridging in brine tank: Break up salt bridges with a broom handle or similar tool. Consider switching salt types if bridging is frequent.

Advanced Tips for Optimizing Fleck 5600 SXT Performance

  • Use High-Quality Salt: Opt for pellet or crystal salt designed for water softeners to reduce impurities and bridging.
  • Regular Water Testing: Test water hardness annually to adjust programming as needed.
  • Seasonal Programming Adjustments: Increase regeneration frequency during periods of higher water usage or hardness fluctuations.
  • Install a Pre-Filter: Adding a sediment filter upstream can prolong resin life by reducing particulate contamination.

Conclusion

Proper installation of the Pentair water softener head using the Fleck 5600 SXT Meter Valve is essential for the effective and efficient operation of your water softening system. By following this detailed guide—from preparation to programming and maintenance—you can ensure your system delivers consistently softened water while optimizing salt and water usage. Routine maintenance and timely troubleshooting will extend the life of your equipment and maintain water quality for years to come.

Calibrating the Metered Valve for Accurate Water Usage

To maximize the efficiency of the Fleck 5600 SXT Meter Valve, proper calibration of the water meter is essential. The valve measures water flow to determine when regeneration is necessary, so inaccurate calibration can lead to premature or delayed regeneration cycles.

  • Locate the Meter Calibration Setting: Access the valve’s programming menu and find the meter calibration parameter, usually indicated in gallons or liters per pulse.
  • Perform a Flow Test: Using a known volume container, allow water to flow through the system while observing the meter’s pulse count or flow display.
  • Calculate the Correct Calibration: Divide the volume of water by the number of pulses recorded to determine gallons per pulse.
  • Adjust the Valve Setting: Enter the calculated value into the valve’s calibration setting to ensure accurate measurement of water usage.

Regularly recalibrate the meter, especially if noticeable changes in water consumption or regeneration frequency occur, to maintain optimal performance.

Winterizing Your Pentair Water Softener System

If the water softener is installed in an area subject to freezing temperatures, winterization is crucial to prevent damage to the Fleck 5600 SXT valve and other components.

  • Drain the System: Shut off the water supply and bypass the softener. Open drain valves to remove water from the resin tank, brine tank, and valve.
  • Remove the Valve: If possible, detach the valve and store it in a frost-free location.
  • Protect the Brine Tank: Empty the brine tank and store salt in a dry, indoor space.
  • Insulate Pipes and Tanks: Use foam pipe insulation or heat tape on exposed plumbing to prevent freezing.
  • Restarting Post-Winter: Inspect the system for leaks or damage, refill the brine tank with salt, and reprogram the valve before restoring water supply.

Proper winterization prevents costly repairs and ensures the longevity of your water softener system.

Upgrading and Replacing the Fleck 5600 SXT Valve

Over time, wear and tear may necessitate upgrading or replacing the Pentair water softener head. Common signs that indicate replacement include erratic regeneration cycles, persistent leaks, or failure to advance through cycles despite troubleshooting.

  • Assess Compatibility: The Fleck 5600 SXT valve is compatible with many resin tanks, but verify size and threading before purchasing a replacement.
  • Backup Settings: Before removal, record all current programming parameters to facilitate quick setup of the new valve.
  • Careful Removal: Turn off water and power, bypass the softener, and carefully unscrew the old valve from the tank.
  • Install the New Valve: Follow the installation steps outlined previously, ensuring all connections are secure and leak-free.
  • Test and Program: Power on the new valve, input saved settings, and run a manual regeneration to verify operation.

Replacing the valve can restore system efficiency and extend the overall life of your water softener.

Conclusion

Installing and maintaining the Pentair water softener head with the Fleck 5600 SXT Meter Valve requires careful attention to detail but delivers significant benefits in water quality and system efficiency. From initial setup and calibration to routine maintenance and winterization, understanding each step ensures your water softener operates reliably and economically. Whether you are installing a new system or upgrading an existing valve, following best practices will help you enjoy the full advantages of softened water for years to come.

PageID: 15837342010078347317