Introduction: Making Installation Easy and Efficient

Installing a water pressure tank like the WellMate 80-Gallon model is a critical step in ensuring reliable water service in your well system. Designed with user-friendly features, this tank simplifies setup and maintenance, letting you focus on enjoying consistent water pressure without hassle.

Preparation Before Installation

  • Assess the Installation Site: Choose a dry, level, and accessible location near your well pump. The site should be able to support the tank’s dimensions (21 inches in diameter and 62 inches in height) and should consider future access for servicing.
  • Gather Tools and Materials: You will need standard plumbing tools, compatible fittings, and possibly clamps or straps to secure the tank if necessary. Ensure you have the appropriate connections for your plumbing materials, whether plastic, metallic, threaded, or soldered.
  • Check Water System Compatibility: The WellMate WM-23 features a flexible connection system, so verify your existing plumbing setup can accommodate the quick connect fittings.

Step-by-Step Installation Process

1. Prepare the Base

Ensure the installation area has a sturdy, level base—such as a concrete pad or a compacted gravel bed—that can support the weight of an 80-gallon tank filled with water. Proper support is essential to prevent movement or damage during operation.

2. Position the Tank

Carefully place the WellMate tank on the prepared base. Remember, this tank’s design allows it to be rotated after installation, so you can orient it for optimal accessibility of product specifications and labels.

3. Connect the Plumbing

The Quick Connect design is engineered to simplify installation. Here’s how to achieve a secure and leak-free setup:

  • Identify the service connection point on the tank, which features a threadless connection system.
  • Select the appropriate fittings for your plumbing materials; the connection system accommodates plastic, metallic, threaded, or sweat fittings.
  • Attach the fittings following manufacturer instructions. The threadless, captive design eliminates the need for thread sealant or Teflon tape, streamlining the process.
  • Ensure all connections are snug but not over-tightened, to maintain integrity and avoid damage.

4. Connect the Tank Drain Assembly

The drain assembly also features a threadless connection, allowing for quick and secure attachment to your drain piping. Use appropriate fittings, ensuring a tight, leak-free connection that will facilitate future draining or maintenance tasks.

5. Finalize the Setup

  • Double-check all fittings and connections for tightness.
  • Ensure the tank is properly supported and not in contact with sharp edges or supports that could cause wear.
  • If applicable, secure the tank to prevent movement during water pressure surges or external vibrations.

Initial System Setup and Configuration

Once the tank is physically installed, proceed with system start-up:

  • Turn on your well pump and observe the connections for leaks. The threadless connection design minimizes the risk of leaks, but it's important to verify.
  • Adjust the system’s pressure settings as needed. The composite shell and captive-air design work together to maintain steady household pressure and reduce pump cycling, extending system longevity.
  • For systems requiring chlorine disinfection, the WellMate's replaceable butyl air cell can be used, ensuring continuous chlorine use doesn’t degrade internal components and maintaining water quality.

Servicing and Maintenance Tips

  • Periodic Inspection: Regularly check all fittings and connections for secure fit and signs of wear.
  • Air Cell Replacement: When necessary, the replaceable air cell can be serviced without removing the entire tank, simplifying maintenance.
  • Cleaning: The seamless composite shell prevents rust and corrosion, reducing maintenance needs over time.
  • System Monitoring: Maintain consistent water pressure and volume by monitoring the pump cycle count and listening for irregular sounds that may indicate issues.

Conclusion: Simplified Installation for Long-term Performance

The WellMate 80-Gallon tank is designed with ease of installation and long-term serviceability in mind. Its threadless connections and innovative features make setup more straightforward than traditional tanks, saving time and reducing installation errors. Proper placement, secure connections, and regular maintenance ensure your water system operates smoothly for years to come.

Installation considerations for local homes

In this area, many homes have limited basement or utility room space, making optimal positioning crucial for the WellMate 80-Gallon tank. It should be placed where there is enough clearance for maintenance and inspection. If space is tight, consider placing the tank against a wall to maximize available room.

Drain access is another important factor; ensure that the area around the tank allows for easy drainage during any service or maintenance activities. Install a bypass valve to manage water flow efficiently during any plumbing adjustments. Additionally, assess the typical plumbing layout in local homes, which often includes copper or PVC pipes, to ensure compatibility with the tank’s connection system.