{"title":"Stenner","description":null,"products":[{"product_id":"stmccvdbo-stenner-duck-bill-check-vlv-5-pk-mccvdb0","title":"STMCCVDBO, Stenner Duck Bill Check Vlv (5 Pk), MCCVDB0","description":"\u003cp\u003e\u003cstrong\u003eSTMCCVDBO Stenner Duck Bill Check Valve: Ensure Reliable Chemical Feed Pump Protection\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDesigned specifically for chemical feed pumps, the STMCCVDBO Stenner Duck Bill Check Valve offers a dependable solution to prevent backflow and contamination in your water treatment systems. This 5-pack of durable check valves ensures smooth, uninterrupted operation by maintaining proper chemical flow control. Incorporating key components for chemical feed pumps and accessories, these valves help safeguard your system’s efficiency and longevity.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePrevents backflow to protect your chemical feed pump from damage and contamination.\u003c\/li\u003e\n  \u003cli\u003eMaintains consistent chemical dosing, enhancing system performance and water quality.\u003c\/li\u003e\n  \u003cli\u003eDurable construction resists wear and chemical degradation for long-lasting use.\u003c\/li\u003e\n  \u003cli\u003eEasy to install and replace, minimizing downtime and maintenance effort.\u003c\/li\u003e\n  \u003cli\u003eCompact design fits seamlessly with most standard chemical feed pump setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe Stenner Duck Bill Check Valve functions as a one-way valve that allows chemical solutions to flow in a single direction—toward the treatment system—while preventing any backflow that could contaminate the pump or feed lines. Its flexible duck bill-shaped opening expands to permit flow under pressure and closes tightly to block reverse flow, ensuring chemical dosing remains accurate and safe.\u003c\/p\u003e\n\u003cp\u003eInstalled directly in the chemical feed line, this valve acts as a critical barrier that protects your pump and system components from potential damage caused by back-siphoning or pressure fluctuations.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eUpon installation, you will notice immediate improvement in chemical feed consistency and system stability due to the elimination of backflow issues. In the first few days and weeks, the valve maintains smooth operation with minimal pressure loss, ensuring your chemical feed pumps operate efficiently.\u003c\/p\u003e\n\u003cp\u003eOver the longer term, expect reliable performance with minimal maintenance required. The valve’s robust materials resist chemical wear, so routine inspection and timely replacement within the 5-pack will keep your water treatment system running smoothly.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDuck Bill Valve Membrane\u003c\/strong\u003e – Flexible elastomer that allows one-way chemical flow and prevents backflow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePolymer Housing\u003c\/strong\u003e – Chemical-resistant body that protects internal components and withstands harsh environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure Fitting Interface\u003c\/strong\u003e – Ensures leak-free connection to standard chemical feed pump tubing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePack of 5 Valves\u003c\/strong\u003e – Provides multiple replacements for ongoing maintenance and system reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the old check valve or prepare the feed line for installation.\u003c\/li\u003e\n  \u003cli\u003eInsert the Stenner Duck Bill Check Valve into the chemical feed line in the correct flow direction, ensuring the duck bill end points downstream.\u003c\/li\u003e\n  \u003cli\u003eSecurely attach tubing connectors to prevent leaks.\u003c\/li\u003e\n  \u003cli\u003eRestore system pressure and turn the pump back on, checking for proper operation and absence of backflow.\u003c\/li\u003e\n  \u003cli\u003eRegularly inspect the valve for wear and replace as needed using the extra valves in the 5-pack.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered specifically for chemical feed pump applications, guaranteeing compatibility and performance.\u003c\/li\u003e\n  \u003cli\u003eConstructed from high-quality, chemical-resistant materials for durability and extended service life.\u003c\/li\u003e\n  \u003cli\u003eOffered by Water Softener Plus, a trusted vendor known for reliable water treatment components.\u003c\/li\u003e\n  \u003cli\u003eAvailable in convenient multi-packs to support routine maintenance and reduce operational downtime.\u003c\/li\u003e\n  \u003cli\u003eDesigned to integrate seamlessly with existing chemical feed pump systems, optimizing your water treatment process.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this check valve compatible with all Stenner chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eYes, the STMCCVDBO is designed to fit standard Stenner chemical feed pump models and similar systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the check valve be replaced?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on chemical concentration and usage but typically every 6-12 months or when signs of wear appear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this valve handle harsh chemical solutions?\u003c\/strong\u003e\u003cbr\u003eYes, its chemical-resistant materials are suitable for common feed chemicals used in water treatment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs installation difficult for non-professionals?\u003c\/strong\u003e\u003cbr\u003eInstallation is straightforward with basic tools; however, following safety precautions and manufacturer guidelines is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the valve require any maintenance?\u003c\/strong\u003e\u003cbr\u003eRoutine inspection for cracks or leaks is advised, but no special maintenance is needed beyond timely replacement.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STMCCVDBO Stenner Duck Bill Check Valve 5-pack to your cart and keep your water flowing clean and consistent with efficient chemical feed protection.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819818577973,"sku":"780851339698","price":40.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stmccvdbo.jpg?v=1764174720"},{"product_id":"stmccp202-5-stenner-2-tube-assm-5-pk-mccp202","title":"STMCCP202-5, Stenner #2 Tube Assm. (5-Pk), MCCP202","description":"\u003cp\u003e\u003cstrong\u003eSTMCCP202-5 Stenner #2 Tube Assembly: Ensure Reliable Chemical Feed Pump Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining optimal operation of your chemical feed pumps, the STMCCP202-5 Stenner #2 Tube Assembly offers a dependable and efficient solution. Designed specifically for chemical feed pump systems, this tube assembly ensures consistent chemical delivery and prevents common issues like leaks or tube degradation. As a vital replacement part in the Chemical Feed Pumps Part and Accessories category, it’s engineered to enhance system reliability and longevity.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintains precise chemical dosing for water treatment systems\u003c\/li\u003e\n  \u003cli\u003eResists wear and chemical corrosion to extend tube life\u003c\/li\u003e\n  \u003cli\u003eEasy to install, minimizing downtime during maintenance\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner #2 pump models, ensuring a secure fit\u003c\/li\u003e\n  \u003cli\u003ePrevents leaks and chemical waste, improving system efficiency\u003c\/li\u003e\n  \u003cli\u003ePack of 5 tubes provides cost-effective bulk replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STMCCP202-5 tube assembly serves as the critical conduit for chemical solutions within your Stenner #2 chemical feed pump. As the pump operates, this tube allows for smooth, controlled flow of chemicals, ensuring accurate dosing into your water system. Its durable material withstands the pressures and corrosive nature of common treatment chemicals, maintaining integrity over time.\u003c\/p\u003e\n\u003cp\u003eInstalled inside the pump head, the tube flexes in sync with the pump’s diaphragm movement, facilitating consistent chemical transfer without leaks or blockages. This precision helps your water softening or treatment setup function optimally, preventing system failures caused by faulty tubing.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eImmediately after installation, you’ll notice a secure fit and seamless integration with your existing Stenner #2 pump. The tube assembly’s flexible yet robust design reduces the risk of leaks, allowing your chemical feed system to resume normal operation quickly. In the first few days, the tube will settle into its role, delivering consistent chemical flow without interruption.\u003c\/p\u003e\n\u003cp\u003eOver weeks and months, expect reliable performance with minimal need for adjustments, thanks to the tube’s resistance to wear and chemical exposure. Regular inspection during routine pump maintenance will help prolong its lifespan, ensuring your water treatment system remains efficient and trouble-free.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-grade chemical-resistant tubing – ensures durability against corrosive feed solutions\u003c\/li\u003e\n  \u003cli\u003ePrecision-engineered connectors – for a tight, leak-proof fit within the pump assembly\u003c\/li\u003e\n  \u003cli\u003eFlexible yet strong material composition – balances resilience with necessary flexibility\u003c\/li\u003e\n  \u003cli\u003e5-tube pack – offers multiple replacements to keep your chemical feed pumps operating continuously\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before beginning.\u003c\/li\u003e\n  \u003cli\u003eRemove the old tube assembly carefully from the pump head.\u003c\/li\u003e\n  \u003cli\u003eInspect the pump fittings and clean if necessary to ensure a proper seal.\u003c\/li\u003e\n  \u003cli\u003eInsert the new STMCCP202-5 tube assembly into the pump connectors, confirming a secure connection.\u003c\/li\u003e\n  \u003cli\u003eRestore system pressure and power to the pump, then check for leaks or irregular flow.\u003c\/li\u003e\n  \u003cli\u003eMonitor the system during initial operation to verify consistent chemical dosing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eConstructed with quality materials designed specifically for chemical feed applications\u003c\/li\u003e\n  \u003cli\u003eTrusted vendor, Water Softener Plus, known for reliable water treatment components\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of chemical feed pump setups, especially Stenner #2 series\u003c\/li\u003e\n  \u003cli\u003eBulk 5-pack offers excellent value for ongoing maintenance needs\u003c\/li\u003e\n  \u003cli\u003eDesigned to withstand harsh chemical environments, reducing replacement frequency\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs this tube assembly compatible with all Stenner pumps?\u003c\/strong\u003e\u003cbr\u003eThe STMCCP202-5 is designed specifically for Stenner #2 pump models; verify your model before purchase for proper fit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the tube assembly?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on usage and chemical type, but routine inspection every 6-12 months is recommended.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I install this tube assembly myself?\u003c\/strong\u003e\u003cbr\u003eYes, installation is straightforward with basic mechanical skills; always follow safety precautions to avoid chemical exposure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the tubing resistant to chemical corrosion?\u003c\/strong\u003e\u003cbr\u003eYes, the tubing material is chemically resistant to common feed solutions used in water treatment systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat maintenance is required after installation?\u003c\/strong\u003e\u003cbr\u003eRegularly check for leaks or wear during scheduled pump maintenance and replace tubing as needed to maintain system integrity.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STMCCP202-5 Stenner #2 Tube Assembly (5-Pk) to your cart and keep your chemical feed pumps delivering precise, consistent performance for cleaner, safer water treatment.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819818676277,"sku":"780851339701","price":160.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/uccp202.jpg?v=1764174723"},{"product_id":"stucdbinj-stenner-inj-ck-vlv-1-4-ucdbinj","title":"STUCDBINJ, Stenner Inj Ck Vlv,1\/4, UCDBINJ","description":"\u003cp\u003e\u003cstrong\u003eReliable Check Valve for Chemical Feed Pumps – Ensure Efficient and Leak-Free Injection\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STUCDBINJ Stenner Injection Check Valve is designed to provide dependable backflow prevention in chemical feed pump systems. Unlike generic valves, this model offers superior sealing and durability for water treatment setups, ensuring your chemical feed remains consistent and safe. Ideal for use in chemical feed pumps and accessories, it reduces the risk of contamination and system inefficiencies.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePrevents backflow to protect your chemical feed system from contamination\u003c\/li\u003e\n  \u003cli\u003eDurable construction for long-lasting performance under varying pressures\u003c\/li\u003e\n  \u003cli\u003eCompact 1\/4” size fits seamlessly into most injection line setups\u003c\/li\u003e\n  \u003cli\u003eReduces maintenance needs by minimizing leaks and valve failures\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of chemical feed pumps and accessories\u003c\/li\u003e\n  \u003cli\u003eEnsures consistent chemical dosing for optimal water treatment results\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThis check valve functions as a one-way gate within your chemical feed pump system, allowing chemicals to flow in only one direction—toward your water treatment process. By preventing reverse flow, it stops contaminants or untreated water from entering the chemical feed line, which could otherwise cause system malfunctions or inefficiencies.\u003c\/p\u003e\n\u003cp\u003eInstalled inline with a 1\/4” injection tubing, the valve’s internal mechanism automatically closes when flow stops, maintaining system integrity without manual intervention. This simple yet effective design supports reliable chemical dosing and extends the life of your pump components.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installation, you’ll immediately notice enhanced flow control and peace of mind knowing your chemical feed line is protected against backflow. Over the first few days, the valve will settle into smooth operation, ensuring consistent chemical injection without leaks.\u003c\/p\u003e\n\u003cp\u003eIn the longer term, this check valve requires minimal maintenance and delivers reliable performance, reducing downtime and protecting your water treatment system. Regular inspection during routine maintenance will keep your setup functioning optimally.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePolymer valve housing\u003c\/strong\u003e – Provides chemical resistance and protects internal parts from corrosion\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSpring-loaded check mechanism\u003c\/strong\u003e – Ensures quick and secure valve closure to prevent backflow\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1\/4” connection ports\u003c\/strong\u003e – Standard sizing for easy integration with most chemical feed pumps and tubing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSealing components\u003c\/strong\u003e – Designed to maintain leak-free operation under typical system pressures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before installation.\u003c\/li\u003e\n  \u003cli\u003eCut the injection tubing at the desired inline location and insert the check valve, ensuring correct flow direction (indicated by arrow on the valve body).\u003c\/li\u003e\n  \u003cli\u003eSecure the valve connections firmly to prevent leaks, using appropriate clamps if necessary.\u003c\/li\u003e\n  \u003cli\u003eTurn the chemical feed pump back on and observe the system for any leaks or irregular flow.\u003c\/li\u003e\n  \u003cli\u003ePeriodically inspect the valve during routine system maintenance to ensure continued performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered by Water Softener Plus for dependable chemical feed pump compatibility\u003c\/li\u003e\n  \u003cli\u003eBuilt with durable materials that withstand harsh chemical environments\u003c\/li\u003e\n  \u003cli\u003eCompact and precise design ensures seamless integration into standard water treatment systems\u003c\/li\u003e\n  \u003cli\u003eTrusted solution for preventing backflow and maintaining consistent chemical dosing\u003c\/li\u003e\n  \u003cli\u003eSupports system longevity by reducing wear on pumps and related components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this check valve compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed for use with most pumps that utilize 1\/4” injection tubing, but always verify your system specifications before purchasing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I inspect or replace this valve?\u003c\/strong\u003e\u003cbr\u003eInspection during routine maintenance every few months is recommended; replacement depends on wear signs or valve performance issues.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this valve handle corrosive chemicals?\u003c\/strong\u003e\u003cbr\u003eThe polymer housing and internal components are resistant to many common chemicals used in water treatment, but check chemical compatibility based on your specific application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if the valve fails?\u003c\/strong\u003e\u003cbr\u003eA failure could allow backflow, risking contamination or pump damage, so proper installation and maintenance are essential.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs installation difficult?\u003c\/strong\u003e\u003cbr\u003eInstallation is straightforward and can typically be done without professional help, provided system pressure is relieved and flow direction is observed.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this STUCDBINJ check valve to your cart and keep your chemical feed pumps operating smoothly with consistent, leak-free injection.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819818709045,"sku":"780851339683","price":54.66,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stucdbinj.jpg?v=1764174726"},{"product_id":"stuccp202-stenner-2-tube-assm-1-4-2-pk-uccp202","title":"STUCCP202, Stenner #2 Tube Assm,1\/4 (2 Pk), UCCP202","description":"\u003cp\u003e\u003cstrong\u003eReliable Stenner #2 Tube Assembly for Chemical Feed Pumps – Ensure Precise and Consistent Chemical Delivery\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STUCCP202 Stenner #2 Tube Assembly is designed specifically to solve common issues in chemical feed pump maintenance by providing a durable, high-quality replacement tube that fits perfectly and performs consistently. Whether you’re managing water treatment systems or chemical dosing setups, this 1\/4-inch tube assembly ensures efficient chemical feed pump operation, reducing downtime and improving system reliability.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMaintains accurate chemical dosing to protect your water treatment system’s efficiency\u003c\/li\u003e\n  \u003cli\u003eReduces risk of leaks and failures with a precision-engineered tube assembly\u003c\/li\u003e\n  \u003cli\u003eEasy installation and replacement saves time during maintenance cycles\u003c\/li\u003e\n  \u003cli\u003eDurable construction withstands chemical exposure and system pressure\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner #2 chemical feed pumps for seamless integration\u003c\/li\u003e\n  \u003cli\u003ePack of two tubes ensures you have a spare ready for quick swaps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThis Stenner tube assembly functions as the critical pathway for chemical solutions within your chemical feed pump system. The 1\/4-inch tubing is designed to handle the precise flow of chemicals from the pump’s dosing head into your water treatment setup, ensuring consistent and controlled feed rates.\u003c\/p\u003e\n\u003cp\u003eInstalled inside the pump head, the tube contracts and expands with the pump’s diaphragm action, moving chemicals without leaks or interruptions. Its compatibility with Stenner #2 pumps guarantees a snug fit that maintains system integrity and chemical dosing accuracy.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installation, you will immediately notice smooth and reliable chemical feed performance with minimal risk of leaks or tube fatigue. Over the first few days and weeks, the tube assembly will establish consistent flow rates, helping maintain your water treatment system’s balance and effectiveness.\u003c\/p\u003e\n\u003cp\u003eWith proper installation and regular inspection, this tube assembly offers long-term reliability, resisting chemical corrosion and wear. Replacing worn tubes proactively will keep your pump running efficiently and help avoid costly downtime.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo 1\/4-inch Stenner #2 Replacement Tubes – precision-made for accurate chemical dosing and durability\u003c\/li\u003e\n  \u003cli\u003eChemical-resistant tubing material – designed to withstand harsh feed chemicals without degradation\u003c\/li\u003e\n  \u003cli\u003eExact fit design – ensures compatibility and leak-free connections within Stenner #2 chemical feed pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before starting.\u003c\/li\u003e\n  \u003cli\u003eRemove the old tube assembly carefully, noting its routing and attachment points.\u003c\/li\u003e\n  \u003cli\u003eInsert the new tube assembly into the pump head, ensuring a secure and tight fit.\u003c\/li\u003e\n  \u003cli\u003eCheck for proper seating and alignment within the pump mechanism.\u003c\/li\u003e\n  \u003cli\u003eRestore system pressure and switch the pump back on, observing for any leaks.\u003c\/li\u003e\n  \u003cli\u003eRun the pump briefly to confirm consistent chemical flow through the new tube.\u003c\/li\u003e\n  \u003cli\u003eKeep the spare tube handy for future maintenance or emergency replacements.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to meet stringent quality and durability standards for chemical feed pumps\u003c\/li\u003e\n  \u003cli\u003eTrusted vendor, Water Softener Plus, known for reliable water treatment components and accessories\u003c\/li\u003e\n  \u003cli\u003eSpecifically designed for Stenner #2 pump models, ensuring perfect compatibility\u003c\/li\u003e\n  \u003cli\u003eIdeal for maintaining and extending the lifespan of your chemical feed pump system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this tube assembly compatible with all Stenner pumps?\u003c\/strong\u003e\u003cbr\u003eThis assembly is specifically designed for Stenner #2 chemical feed pumps; compatibility with other models may vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the tube assembly?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on usage and chemical type, but regular inspection every 6-12 months is recommended to prevent wear-related failures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this tube assembly myself?\u003c\/strong\u003e\u003cbr\u003eYes, installation is straightforward with basic tools and safety precautions; ensure the pump is off and depressurized before starting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat chemicals is this tube compatible with?\u003c\/strong\u003e\u003cbr\u003eThe tube is made from chemical-resistant materials suitable for most common water treatment chemicals, but always verify compatibility with your specific chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any safety precautions I should take during installation?\u003c\/strong\u003e\u003cbr\u003eWear appropriate gloves and eye protection, and avoid direct contact with chemicals when handling the tube assembly.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STUCCP202 Stenner #2 Tube Assembly to your cart and keep your chemical feed pump delivering precise, consistent performance for cleaner, safer water treatment.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819818774581,"sku":"780851339687","price":72.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stuccp202.jpg?v=1764174729"},{"product_id":"fp30-115-stenner-fp-series-30-gpd-115v-e20phh81s7","title":"FP30-115, Stenner FP Series 30 GPD 115v, E20PHH81S7","description":"\u003c!--wsp-trust-v1--\u003e\u003cdiv class=\"wsp-trust\" style=\"border:1px solid #e5e7eb;border-radius:10px;padding:12px 14px;margin:0 0 14px;background:#f9fafb;font-size:14px;\"\u003e\n\u003cstrong\u003eWhy buy from Water Softener Plus\u003c\/strong\u003e\u003cbr\u003e✔ US-based water treatment specialists   ✔ Ships nationwide \u0026amp; worldwide   ✔ Buy now, pay over time with Shop Pay\u003cbr\u003e✔ Free shipping on US orders over $1,000   ✔ Secure checkout   ✔ Easy returns   ✔ Free expert sizing help — call \u003ca href=\"tel:+18136211985\"\u003e813-621-1985\u003c\/a\u003e   ✔ Free install \u0026amp; service \u003ca href=\"\/zh-hans-as\/manuals\"\u003emanuals\u003c\/a\u003e included\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump for Precise Water Treatment and System Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe Stenner FP30-115 from the FP Series delivers consistent 30 GPD dosing at 115 volts, designed specifically for chemical feed pumps applications in water treatment systems. Unlike generic pumps, this model offers dependable performance and precise chemical dosing, helping you maintain optimal water quality and system safety. As part of the trusted Chemical Feed Pumps Part and Accessories, it addresses common challenges like uneven chemical delivery and pump failure.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures accurate chemical dosing to protect your water treatment system\u003c\/li\u003e\n  \u003cli\u003eSupports continuous operation with durable, high-quality components\u003c\/li\u003e\n  \u003cli\u003eReduces maintenance frequency thanks to reliable motor and pump design\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of chemicals used in water softening and treatment\u003c\/li\u003e\n  \u003cli\u003eEasy integration into existing systems due to standard 115v power requirements\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight design simplifies installation and handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe FP30-115 pump operates by precisely delivering measured amounts of chemicals into your water system, ensuring proper treatment levels. It uses a motor-driven diaphragm mechanism to push the chemical solution at a steady rate of 30 gallons per day, which is ideal for maintaining balanced water chemistry and preventing scaling or corrosion.\u003c\/p\u003e\n\u003cp\u003eInstalled inline with your water treatment setup, this chemical feed pump automatically adjusts dosing based on system demands, providing consistent performance without manual intervention. Its reliable electrical design ensures stable operation at 115 volts, making it suitable for residential and commercial water softener applications.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eRight after installation, you will notice improved chemical dosing accuracy, leading to better control over water hardness and contaminant levels. In the first days and weeks, the pump will run quietly and efficiently, requiring minimal adjustments as it settles into your system’s specific needs.\u003c\/p\u003e\n\u003cp\u003eOver time, the FP30-115 maintains consistent performance with minimal maintenance. Routine checks and occasional cleaning will keep it running smoothly, ensuring long-term reliability and helping you avoid costly downtime or water quality issues.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHeavy-duty motor – Provides reliable power and consistent dosing at 115 volts\u003c\/li\u003e\n  \u003cli\u003eDurable diaphragm assembly – Ensures precise chemical delivery without leaks\u003c\/li\u003e\n  \u003cli\u003eRobust pump housing – Protects internal components and resists chemical corrosion\u003c\/li\u003e\n  \u003cli\u003eStandard inlet and outlet fittings – Simplify connection to existing water treatment lines\u003c\/li\u003e\n  \u003cli\u003eControl panel with adjustment features – Allows fine-tuning of chemical feed rate\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the water treatment system and power supply before installation.\u003c\/li\u003e\n  \u003cli\u003eMount the FP30-115 pump securely near your chemical reservoir according to manufacturer guidelines.\u003c\/li\u003e\n  \u003cli\u003eConnect the inlet and outlet tubing to your water treatment system’s chemical feed lines.\u003c\/li\u003e\n  \u003cli\u003ePlug the pump into a 115v power source and switch it on.\u003c\/li\u003e\n  \u003cli\u003eAdjust the feed rate using the control panel to match your system’s chemical dosing requirements.\u003c\/li\u003e\n  \u003cli\u003eMonitor the initial operation for proper flow and check for leaks.\u003c\/li\u003e\n  \u003cli\u003ePerform periodic maintenance as recommended to ensure longevity and performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt with high-quality materials designed to withstand chemical exposure and continuous use\u003c\/li\u003e\n  \u003cli\u003eManufactured by a trusted vendor specializing in water softener and chemical feed pump parts\u003c\/li\u003e\n  \u003cli\u003eOptimized for seamless integration into various water treatment systems, enhancing overall efficiency\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight, making it easy to install and maintain in tight spaces\u003c\/li\u003e\n  \u003cli\u003eOffers precise and consistent chemical feed to protect your investment in water treatment infrastructure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the FP30-115 compatible with all water softener systems?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most systems requiring a 30 GPD chemical feed pump operating at 115 volts, but always verify your system’s specifications before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I perform maintenance on this pump?\u003c\/strong\u003e\u003cbr\u003eRoutine checks every few months are recommended, including inspecting tubing, cleaning the diaphragm, and verifying dosing accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this pump handle different types of chemicals?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed to work with a variety of common water treatment chemicals, but always consult chemical compatibility guidelines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating conditions should I avoid?\u003c\/strong\u003e\u003cbr\u003eAvoid exposure to extreme temperatures outside the pump’s rated range and ensure it is installed in a dry, ventilated area.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I adjust the dosing rate?\u003c\/strong\u003e\u003cbr\u003eUse the built-in control panel dial or settings to increase or decrease the chemical feed rate as needed.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e\u003c!--wsp-xsell-v1--\u003e\u003cdiv class=\"wsp-xsell\" style=\"margin-top:18px;\"\u003e\n\u003ch2\u003eComplete your system\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/filter-cartridges\"\u003eReplacement filters \u0026amp; cartridges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/resins-filter-media-chemicals\"\u003eMedia \u0026amp; chemicals\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/control-valves-parts\"\u003eParts \u0026amp; accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819818807349,"sku":"780851339113","price":897.54,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fp30-115.jpg?v=1764174733"},{"product_id":"stucthc2d-stenner-complete-hsng-w-2-tube-qp252-1","title":"STUCTHC2D, Stenner Complete Hsng w\/ #2 tube, QP252-1","description":"\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump Housing for Efficient Water Treatment Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STUCTHC2D Stenner Complete Housing with #2 Tube, QP252-1, is designed to enhance the durability and functionality of your chemical feed pump system. This high-quality housing ensures precise chemical delivery and protects your system’s components from wear and damage. Ideal for water treatment applications, it offers a dependable solution for maintaining consistent chemical feed performance in your setup.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures accurate chemical dosing for optimal water treatment results\u003c\/li\u003e\n  \u003cli\u003eProtects internal pump components from corrosion and mechanical damage\u003c\/li\u003e\n  \u003cli\u003eDurable construction extends the lifespan of your chemical feed pump assembly\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner #2 tubing for seamless integration and easy installation\u003c\/li\u003e\n  \u003cli\u003eLightweight design reduces strain on pump motors, improving overall efficiency\u003c\/li\u003e\n  \u003cli\u003eMinimizes downtime with reliable performance in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThis complete housing assembly encases the #2 tube, which is responsible for transporting chemicals from the reservoir to the treatment system. By securely holding the feed tube in place, it ensures consistent flow rates and prevents leaks or interruptions in chemical delivery. The housing also safeguards the internal components from exposure to harsh chemicals and environmental factors, maintaining system integrity.\u003c\/p\u003e\n\n\u003cp\u003eInstalled as a key part of the chemical feed pump, this housing enables smooth and controlled pumping action, essential for precise water softening, disinfection, or other water treatment processes.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you will notice a steady and reliable chemical feed with minimal maintenance required. In the initial days, the housing will stabilize the chemical flow, reducing fluctuations commonly caused by worn or damaged components.\u003c\/p\u003e\n\n\u003cp\u003eOver weeks and months, the durable housing helps maintain pump efficiency and reduces the risk of leaks or malfunctions. Routine inspections are simple, as the housing design allows for easy access to the tubing for cleaning or replacement if needed.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePolymer Housing Body\u003c\/strong\u003e – Provides chemical resistance and durability under continuous exposure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e#2 Feed Tube\u003c\/strong\u003e – Ensures precise chemical transport compatible with Stenner pumps.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSealing Gaskets\u003c\/strong\u003e – Prevent leakage and maintain airtight chemical flow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Brackets\u003c\/strong\u003e – Facilitate secure attachment to pump assemblies for stability during operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and release system pressure before installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing housing and #2 tube carefully, ensuring no residual chemicals leak.\u003c\/li\u003e\n  \u003cli\u003eInstall the STUCTHC2D housing by securely attaching it to the pump using the mounting brackets.\u003c\/li\u003e\n  \u003cli\u003eConnect the #2 tube to the housing, ensuring a snug fit to prevent leaks.\u003c\/li\u003e\n  \u003cli\u003eDouble-check all seals and connections before restarting the pump.\u003c\/li\u003e\n  \u003cli\u003ePower on the system and observe for steady chemical flow and absence of leaks.\u003c\/li\u003e\n  \u003cli\u003eSchedule regular inspections to maintain optimal performance and replace tubing as necessary.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured with high-grade materials for long-lasting durability in chemical environments.\u003c\/li\u003e\n  \u003cli\u003eSupported by Water Softener Plus, a trusted vendor in water treatment components.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for chemical feed pump setups, ensuring perfect compatibility and performance.\u003c\/li\u003e\n  \u003cli\u003eLightweight yet robust, it reduces strain on your system while enhancing reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this housing compatible with all Stenner chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed for use with Stenner pumps that utilize #2 tubing, ensuring proper fit and function.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should the #2 tube be replaced?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency varies with usage, but inspecting tubing every 6 months is recommended to prevent wear-related issues.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I install this housing myself?\u003c\/strong\u003e\u003cbr\u003eYes, installation is straightforward with basic tools; however, always follow safety guidelines and disconnect power before starting.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the housing resistant to common chemical feed solutions?\u003c\/strong\u003e\u003cbr\u003eYes, the polymer construction resists corrosion from typical water treatment chemicals.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat maintenance is required for this housing?\u003c\/strong\u003e\u003cbr\u003eRegular visual inspections and cleaning of the tubing and seals will help maintain optimal performance.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819818840117,"sku":"780851339678","price":241.42,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stucthc2d.jpg?v=1764174734"},{"product_id":"stjlp0750-1ppg-stenner-plastic-meter-3-4-1ppg-jlp0750-1ppg","title":"STJLP0750-1PPG, Stenner Plastic Meter, 3\/4\", 1PPG, JLP0750-1PPG","description":"\u003cp\u003e\u003cstrong\u003eReliable Stenner Plastic Meter for Precise Chemical Feed and Enhanced Water Treatment Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STJLP0750-1PPG Stenner Plastic Meter is designed to deliver consistent and accurate chemical dosing, solving common challenges in water treatment systems. Its durable construction and efficient design ensure dependable performance as a key component in chemical feed pumps and accessories. This meter stands out for its precision and reliability, making it an essential upgrade for maintaining optimal water system operation.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures precise chemical dosing to maintain balanced water treatment processes\u003c\/li\u003e\n  \u003cli\u003eProtects your system by preventing overfeed or underfeed of chemicals\u003c\/li\u003e\n  \u003cli\u003eConstructed with durable plastic housing to resist corrosion and extend service life\u003c\/li\u003e\n  \u003cli\u003eSimplifies maintenance with a straightforward design compatible with standard chemical feed pumps\u003c\/li\u003e\n  \u003cli\u003eReduces downtime by providing consistent performance in demanding environments\u003c\/li\u003e\n  \u003cli\u003eLightweight build that integrates seamlessly into existing water treatment setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe Stenner Plastic Meter functions as an integral part of the chemical feed pump system, measuring and controlling the flow rate of chemicals injected into your water treatment process. By accurately metering chemical volume, it ensures that the right amount of treatment chemicals is delivered to the water, optimizing system efficiency and protecting downstream equipment.\u003c\/p\u003e\n\u003cp\u003eThis meter’s plastic construction offers excellent resistance to chemical corrosion, making it suitable for a variety of water treatment chemicals. It operates by precisely regulating flow through its 3\/4\" connection, maintaining consistent dosing rates aligned with your system’s requirements.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eUpon installation, you will notice an immediate improvement in the accuracy of chemical feed dosing, reducing fluctuations common in less precise meters. In the first few days and weeks, the meter will stabilize your chemical input, helping your water treatment system maintain consistent quality.\u003c\/p\u003e\n\u003cp\u003eOver the long term, the STJLP0750-1PPG offers reliable performance with minimal maintenance thanks to its robust plastic design. Routine checks and cleaning will keep your meter functioning optimally, ensuring ongoing protection for your entire water system.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e3\/4\" Plastic Meter Housing – Provides corrosion resistance and durability\u003c\/li\u003e\n  \u003cli\u003ePrecision Flow Metering Mechanism – Ensures accurate chemical dosing\u003c\/li\u003e\n  \u003cli\u003eSealed Connection Ports – Prevent leaks and maintain system integrity\u003c\/li\u003e\n  \u003cli\u003eLightweight Internal Components – Facilitate smooth operation and longevity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the water treatment system before installation to ensure safety.\u003c\/li\u003e\n  \u003cli\u003eConnect the Stenner Plastic Meter to your chemical feed pump using the 3\/4\" fittings, ensuring a secure and leak-free connection.\u003c\/li\u003e\n  \u003cli\u003eCalibrate the meter according to your chemical feed requirements and system specifications.\u003c\/li\u003e\n  \u003cli\u003eTurn the system back on and monitor the chemical dosing flow to confirm accurate operation.\u003c\/li\u003e\n  \u003cli\u003ePerform regular inspections and clean the meter as needed to prevent buildup and maintain accuracy.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-quality plastic construction offers long-lasting resistance to chemical corrosion and wear.\u003c\/li\u003e\n  \u003cli\u003eTrusted vendor, Water Softener Plus, known for reliable water treatment components and expert support.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for integration with chemical feed pumps and accessories, ensuring compatibility and ease of use.\u003c\/li\u003e\n  \u003cli\u003eLightweight yet robust, fitting seamlessly into existing water treatment systems without adding complexity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this meter compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed to fit standard 3\/4\" chemical feed pumps and accessories commonly used in water treatment systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I maintain or clean the meter?\u003c\/strong\u003e\u003cbr\u003eRegular inspection every few months is recommended, with cleaning as needed to prevent chemical buildup and ensure accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the meter handle aggressive chemicals?\u003c\/strong\u003e\u003cbr\u003eThe durable plastic housing resists corrosion from a wide range of chemicals typically used in water treatment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended operating temperature range?\u003c\/strong\u003e\u003cbr\u003eThis meter performs best within typical water treatment temperature ranges; consult your system’s specifications for precise limits.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I know if the meter is dosing correctly?\u003c\/strong\u003e\u003cbr\u003eMonitor your system’s chemical feed rates and water quality parameters after installation to confirm proper dosing.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STJLP0750-1PPG Stenner Plastic Meter to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819818872885,"sku":"780851339706","price":477.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stjlp0750-1ppg.jpg?v=1764174740"},{"product_id":"pcm5-stenner-pmp-control-mod-0-5-5-0-seconds-pcm5","title":"PCM5, Stenner Pmp Control Mod, 0.5-5.0 Seconds, PCM5","description":"\u003c!--wsp-trust-v1--\u003e\u003cdiv class=\"wsp-trust\" style=\"border:1px solid #e5e7eb;border-radius:10px;padding:12px 14px;margin:0 0 14px;background:#f9fafb;font-size:14px;\"\u003e\n\u003cstrong\u003eWhy buy from Water Softener Plus\u003c\/strong\u003e\u003cbr\u003e✔ US-based water treatment specialists   ✔ Ships nationwide \u0026amp; worldwide   ✔ Buy now, pay over time with Shop Pay\u003cbr\u003e✔ Free shipping on US orders over $1,000   ✔ Secure checkout   ✔ Easy returns   ✔ Free expert sizing help — call \u003ca href=\"tel:+18136211985\"\u003e813-621-1985\u003c\/a\u003e   ✔ Free install \u0026amp; service \u003ca href=\"\/zh-hans-as\/manuals\"\u003emanuals\u003c\/a\u003e included\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eOptimize Chemical Feed Timing with the PCM5 Stenner Pump Control Module for Precise Water Treatment\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe PCM5 Stenner Pump Control Module offers a reliable solution for water treatment systems requiring accurate chemical dosing. Designed to control pump timing between 0.5 and 5.0 seconds, this module addresses common issues with inconsistent chemical feed and system inefficiencies. For professionals seeking dependable chemical feed pumps parts and accessories, the PCM5 ensures efficient and consistent operation within your water softening or treatment setup.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnables precise control of pump feed cycles for optimal chemical dosing\u003c\/li\u003e\n  \u003cli\u003eImproves system efficiency by reducing overfeed and chemical waste\u003c\/li\u003e\n  \u003cli\u003eEnhances reliability with durable construction suited for water treatment environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of chemical feed pumps, simplifying integration\u003c\/li\u003e\n  \u003cli\u003eEasy to adjust timing between 0.5 and 5.0 seconds to fit specific system needs\u003c\/li\u003e\n  \u003cli\u003eReduces maintenance frequency by stabilizing pump operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe PCM5 control module regulates the on\/off timing of chemical feed pumps, ensuring that chemicals are introduced into the water treatment system at precise intervals. By setting the timing between 0.5 and 5.0 seconds, the module controls the pump’s stroke rate, directly influencing the volume of chemical dispensed.\u003c\/p\u003e\n\u003cp\u003eThis timing control helps maintain consistent chemical levels, which is critical for effective water softening and treatment. The module’s integration with your existing pump allows for smooth, automated operation without manual intervention.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you will notice immediate improvements in chemical feed accuracy, reducing fluctuations in water quality. During the first few days, the PCM5 stabilizes pump cycles, minimizing chemical waste and optimizing system performance.\u003c\/p\u003e\n\u003cp\u003eOver weeks and months, expect increased system reliability with fewer interruptions and maintenance needs. The PCM5’s robust design supports long-term use even in demanding water treatment environments.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTiming Control Circuitry\u003c\/strong\u003e – Precisely manages pump activation intervals for consistent chemical dosing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Housing\u003c\/strong\u003e – Protects internal components from moisture and environmental exposure common in water treatment setups.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdjustable Timer Knob\u003c\/strong\u003e – Allows easy setting of feed duration from 0.5 to 5.0 seconds to match system requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnection Terminals\u003c\/strong\u003e – Provides secure and straightforward wiring to chemical feed pumps and power supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off power to your chemical feed pump before installation to ensure safety.\u003c\/li\u003e\n  \u003cli\u003eMount the PCM5 module securely near the chemical feed pump using appropriate hardware.\u003c\/li\u003e\n  \u003cli\u003eConnect the module’s terminals to the pump’s control wiring following the wiring diagram provided.\u003c\/li\u003e\n  \u003cli\u003eAdjust the timing knob to the desired pump feed duration between 0.5 and 5.0 seconds.\u003c\/li\u003e\n  \u003cli\u003eRestore power and test the pump operation to confirm correct timing and function.\u003c\/li\u003e\n  \u003cli\u003eMake incremental adjustments as needed to optimize chemical feed rates for your system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered for durability and consistent performance in water treatment applications.\u003c\/li\u003e\n  \u003cli\u003eSupported by Water Softener Plus, a trusted vendor specializing in chemical feed pumps parts and accessories.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically to enhance chemical feed pump efficiency and reduce operational errors.\u003c\/li\u003e\n  \u003cli\u003eSimple installation and adjustment make it accessible for both professionals and experienced DIY users.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the PCM5 compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most standard chemical feed pumps but always verify your pump’s specifications before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the PCM5 be maintained?\u003c\/strong\u003e\u003cbr\u003eRoutine inspection every 6 months is recommended to ensure connections remain secure and the timing adjustment operates smoothly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I adjust the feed timing while the pump is running?\u003c\/strong\u003e\u003cbr\u003eFor safety and accuracy, adjust the timing only when the pump is turned off.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating conditions does the PCM5 support?\u003c\/strong\u003e\u003cbr\u003eThe module is designed for typical water treatment environments but should be kept away from direct water exposure and extreme temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the PCM5 require any special power supply?\u003c\/strong\u003e\u003cbr\u003eIt operates on standard power compatible with most chemical feed pumps; consult the manual for specific voltage requirements.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the PCM5 Stenner Pump Control Module to your cart and keep your water flowing clean and consistent with precise chemical dosing control.\u003c\/p\u003e\u003c!--wsp-xsell-v1--\u003e\u003cdiv class=\"wsp-xsell\" style=\"margin-top:18px;\"\u003e\n\u003ch2\u003eComplete your system\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/filter-cartridges\"\u003eReplacement filters \u0026amp; cartridges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/resins-filter-media-chemicals\"\u003eMedia \u0026amp; chemicals\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/control-valves-parts\"\u003eParts \u0026amp; accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819818938421,"sku":"780851339417","price":545.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/pcm5.jpg?v=1764174742"},{"product_id":"stuc3asyd-stenner-roller-assm-uc3asyd","title":"STUC3ASYD, Stenner Roller Assm., UC3ASYD","description":"\u003cp\u003e\u003cstrong\u003eReliable Stenner Roller Assembly for Chemical Feed Pumps – Enhance System Efficiency and Durability\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STUC3ASYD Stenner Roller Assembly by Water Softener Plus offers a dependable solution for maintaining optimal performance in your chemical feed pump system. Designed specifically for chemical feed pumps and accessories, this roller assembly addresses common wear and efficiency issues, ensuring smooth operation and prolonged equipment life. Its robust design makes it an essential part for anyone seeking reliable chemical dosing and water treatment component maintenance.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eImproves chemical feed pump accuracy by ensuring consistent roller movement\u003c\/li\u003e\n  \u003cli\u003eExtends pump component lifespan by reducing wear and tear on tubing\u003c\/li\u003e\n  \u003cli\u003eEnhances system reliability to minimize downtime and maintenance needs\u003c\/li\u003e\n  \u003cli\u003eCompatible with a variety of chemical feed pump models for versatile use\u003c\/li\u003e\n  \u003cli\u003eEasy to install and replace, saving time during routine maintenance\u003c\/li\u003e\n  \u003cli\u003eDesigned with durable materials to withstand harsh chemical environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe Stenner Roller Assembly fits into your chemical feed pump to press the pump tubing, creating a precise and controlled flow of chemicals into your water treatment system. As the roller rotates, it compresses and releases the tubing in a peristaltic motion, which allows accurate chemical dosing without direct contact between the pump mechanism and the liquid.\u003c\/p\u003e\n\u003cp\u003eThis design not only keeps chemical feed consistent but also reduces the risk of leaks and contamination, making it an integral component for effective water softening, filtration, and treatment operations.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installation, you will notice smoother pump operation and consistent chemical dosing immediately. In the first days and weeks, the roller assembly ensures steady flow rates, helping your system maintain water quality and treatment efficiency. Over time, the durable construction reduces the frequency of replacements, contributing to lower maintenance costs and improved long-term system reliability.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePrecision-engineered roller – ensures smooth, consistent tubing compression for accurate chemical dosing\u003c\/li\u003e\n  \u003cli\u003eDurable axle and bearing – supports long-lasting rotation under continuous use\u003c\/li\u003e\n  \u003cli\u003eHigh-quality housing components – protect internal parts from chemical exposure and wear\u003c\/li\u003e\n  \u003cli\u003eCompatible mounting points – designed for easy integration with Stenner and similar chemical feed pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and disconnect power to ensure safety.\u003c\/li\u003e\n  \u003cli\u003eRemove the old roller assembly by loosening the mounting screws and sliding out the component.\u003c\/li\u003e\n  \u003cli\u003eInspect the pump tubing for any wear; replace tubing if necessary before installing the new roller assembly.\u003c\/li\u003e\n  \u003cli\u003eAlign the new STUC3ASYD roller assembly with the pump’s mounting points and secure it firmly.\u003c\/li\u003e\n  \u003cli\u003eReconnect power and run the pump briefly to verify smooth roller movement and proper chemical feed flow.\u003c\/li\u003e\n  \u003cli\u003eMonitor the system for a short period to ensure optimal performance and no unusual noises or vibrations.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt by Water Softener Plus, a trusted name in water treatment parts and accessories\u003c\/li\u003e\n  \u003cli\u003eManufactured with high-quality materials to endure chemical exposure and continuous mechanical stress\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for chemical feed pumps, ensuring precise fit and function\u003c\/li\u003e\n  \u003cli\u003eSupports efficient chemical dosing, improving overall water system performance\u003c\/li\u003e\n  \u003cli\u003eBacked by reliable vendor support and expertise in water treatment components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this roller assembly compatible with all Stenner chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most Stenner models that use the UC3ASYD roller assembly; please verify your pump model before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the roller assembly be replaced?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on usage and chemical type, but typically every 12 to 18 months for optimal performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I clean the roller assembly instead of replacing it?\u003c\/strong\u003e\u003cbr\u003eCleaning is not recommended as it may not restore optimal function and can risk damage to the component.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any special storage requirements for this part?\u003c\/strong\u003e\u003cbr\u003eStore in a cool, dry place away from direct sunlight and corrosive chemicals to maintain part integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs installation safe for non-professionals?\u003c\/strong\u003e\u003cbr\u003eYes, following the step-by-step instructions and safety precautions makes installation straightforward for most users.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STUC3ASYD Stenner Roller Assembly to your cart and keep your chemical feed pump operating smoothly and efficiently for consistent water treatment results.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819818971189,"sku":"780851339693","price":82.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stuc3asyd.jpg?v=1764174743"},{"product_id":"stucfc5id-stenner-index-plate-ucfc5id","title":"STUCFC5ID, Stenner Index Plate, UCFC5ID","description":"\u003cp\u003e\u003cstrong\u003eEnhance Chemical Feed Pump Precision with the STUCFC5ID Stenner Index Plate\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining accurate chemical dosing in water treatment systems, the STUCFC5ID Stenner Index Plate delivers unmatched reliability and efficiency. Designed specifically for chemical feed pumps and accessories, this index plate ensures precise control over pump operation, reducing downtime and enhancing system performance. Its robust build and compatibility with Stenner UCFC5ID models make it a trusted choice for professionals seeking dependable chemical feed pump components.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures precise timing for chemical feed pumps, improving dosing accuracy\u003c\/li\u003e\n  \u003cli\u003eEnhances system reliability by reducing wear and operational errors\u003c\/li\u003e\n  \u003cli\u003eCompatible with a range of Stenner pump models, offering versatile application\u003c\/li\u003e\n  \u003cli\u003eConstructed with durable materials to withstand harsh water treatment environments\u003c\/li\u003e\n  \u003cli\u003eEasy to install replacement part, minimizing downtime during maintenance\u003c\/li\u003e\n  \u003cli\u003eSupports consistent pump performance, helping maintain water quality standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STUCFC5ID index plate functions as a critical timing component within a chemical feed pump assembly. By regulating the rotational position of the pump’s motor shaft, it controls the pump’s chemical injection cycles with high precision. This ensures that chemicals are fed into the water treatment system at exactly the right intervals, preventing over- or under-dosing.\u003c\/p\u003e\n\u003cp\u003eIn water softener and treatment setups, this precise indexing helps maintain optimal chemical levels, which protects equipment and improves overall system efficiency.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the STUCFC5ID index plate, you will notice immediate improvements in your chemical feed pump’s operational smoothness and dosing consistency. Within the first few days, the pump will maintain steady chemical delivery without fluctuations.\u003c\/p\u003e\n\u003cp\u003eOver weeks of use, the durable construction of the index plate ensures it withstands routine wear and tear, reducing the need for frequent replacements. Regular checks can help maintain peak performance, but this component is designed for long-term reliability within chemical feed pump systems.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eIndex Plate – Precisely engineered to provide accurate timing control for pump strokes\u003c\/li\u003e\n  \u003cli\u003eMounting Fittings – Secure the plate firmly in place for stable operation\u003c\/li\u003e\n  \u003cli\u003eDurable Polymer or Metal Construction – Ensures resistance against corrosion and mechanical stress\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off power to the chemical feed pump to ensure safety during installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing index plate by loosening mounting screws or clips.\u003c\/li\u003e\n  \u003cli\u003eAlign the STUCFC5ID index plate with the motor shaft and secure it using the provided fittings.\u003c\/li\u003e\n  \u003cli\u003eDouble-check the alignment to confirm the timing marks correspond with pump specifications.\u003c\/li\u003e\n  \u003cli\u003eRestore power and run a test cycle to verify that chemical dosing operates smoothly and accurately.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to high standards for durability and precise performance in water treatment applications\u003c\/li\u003e\n  \u003cli\u003eBacked by Water Softener Plus, a trusted vendor in chemical feed pump parts and accessories\u003c\/li\u003e\n  \u003cli\u003eDesigned to integrate seamlessly with Stenner UCFC5ID pump models, ensuring compatibility and ease of use\u003c\/li\u003e\n  \u003cli\u003eSupports maintenance goals by reducing the frequency of pump malfunctions related to timing issues\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the STUCFC5ID index plate compatible with all Stenner pumps?\u003c\/strong\u003e\u003cbr\u003eIt is specifically designed for UCFC5ID models but may also fit some other Stenner chemical feed pumps; always check model compatibility before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the index plate be inspected or replaced?\u003c\/strong\u003e\u003cbr\u003eRegular visual inspections during routine maintenance are recommended, with replacement as needed based on wear or damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the index plate myself?\u003c\/strong\u003e\u003cbr\u003eYes, installation is straightforward, but ensure power is off and follow safety guidelines to avoid injury.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the index plate require lubrication?\u003c\/strong\u003e\u003cbr\u003eNo lubrication is needed; it is designed to operate smoothly within the pump assembly without additional maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating conditions are ideal for this component?\u003c\/strong\u003e\u003cbr\u003eIt performs best within typical chemical feed pump environments and should be protected from extreme mechanical shocks or chemical exposure beyond its rated specifications.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your chemical feed pump’s precision and reliability today—add the STUCFC5ID Stenner Index Plate to your cart and ensure consistent, efficient water treatment performance.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819003957,"sku":"780851339680","price":54.34,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stucfc5id.jpg?v=1764174746"},{"product_id":"stucfc5ad-stenner-main-shaft-series-45-85-ucfc5ad","title":"STUCFC5AD, Stenner Main Shaft Series 45 \u0026 85, UCFC5AD","description":"\u003cp\u003e\u003cstrong\u003eSTUCFC5AD Stenner Main Shaft Series 45 \u0026amp; 85 – Reliable Chemical Feed Pump Performance for Water Treatment Systems\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining efficient chemical feed pumps, the STUCFC5AD Stenner Main Shaft Series 45 \u0026amp; 85 offers a dependable solution designed to enhance your water treatment system's reliability. This main shaft replacement part ensures smooth operation, reduces downtime, and supports consistent chemical dosing, making it an essential accessory for chemical feed pumps and their accessories.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures smooth and consistent rotation for accurate chemical feed delivery\u003c\/li\u003e\n  \u003cli\u003eImproves pump longevity by replacing worn or damaged shafts promptly\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner Series 45 and 85 pumps for versatile use\u003c\/li\u003e\n  \u003cli\u003eSupports optimal system performance by preventing mechanical failures\u003c\/li\u003e\n  \u003cli\u003eEasy to install, reducing maintenance time and labor costs\u003c\/li\u003e\n  \u003cli\u003eConstructed with durable materials that withstand chemical exposure\u003c\/li\u003e\n  \u003cli\u003eLightweight design minimizes added strain on pump components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STUCFC5AD main shaft functions as a critical mechanical component within Stenner Series 45 and 85 chemical feed pumps. It transmits rotational force from the pump motor to the diaphragm or piston, enabling precise chemical dosing. By maintaining smooth shaft rotation, it ensures consistent chemical flow rates essential for effective water treatment.\u003c\/p\u003e\n\u003cp\u003eOver time, shafts can wear due to continuous exposure to chemicals and mechanical stress. Replacing the shaft with this high-quality part restores the pump’s operational integrity and prevents potential leaks or dosing inaccuracies caused by shaft damage or misalignment.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the STUCFC5AD main shaft, you will notice improved pump responsiveness and quieter operation. In the first few days, the pump should achieve more consistent chemical dosing without the fluctuations caused by worn components.\u003c\/p\u003e\n\u003cp\u003eWith regular maintenance, this replacement shaft will support long-term pump reliability, reducing the frequency of unexpected downtime and helping you maintain optimal water treatment system performance.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eMain Shaft – precision-engineered to withstand chemical exposure and mechanical stress, ensuring long-lasting pump operation\u003c\/li\u003e\n  \u003cli\u003eDurable Bearing Surface – reduces friction and wear, contributing to smooth rotational movement\u003c\/li\u003e\n  \u003cli\u003eSeal Interface – designed to maintain a tight seal within the pump assembly, preventing leaks and contamination\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and disconnect power supply for safety.\u003c\/li\u003e\n  \u003cli\u003eRemove the pump housing to access the existing main shaft.\u003c\/li\u003e\n  \u003cli\u003eCarefully extract the worn or damaged main shaft from the pump assembly.\u003c\/li\u003e\n  \u003cli\u003eInspect surrounding components for wear; replace if necessary to ensure optimal function.\u003c\/li\u003e\n  \u003cli\u003eInsert the new STUCFC5AD main shaft, ensuring proper alignment and fit.\u003c\/li\u003e\n  \u003cli\u003eReassemble the pump housing securely.\u003c\/li\u003e\n  \u003cli\u003eRestore power and test the pump to confirm smooth operation and consistent chemical dosing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured with high-quality materials to provide durability in demanding chemical environments\u003c\/li\u003e\n  \u003cli\u003eSupported by Water Softener Plus, a trusted vendor specializing in chemical feed pump parts and accessories\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for Stenner Series 45 and 85 pumps, ensuring precise compatibility and performance\u003c\/li\u003e\n  \u003cli\u003eLightweight yet robust, minimizing wear on connected pump components for longer service life\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this main shaft compatible with all Stenner chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eThis shaft is specifically designed for Stenner Series 45 and 85 models. It may not fit other Stenner or pump series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the main shaft?\u003c\/strong\u003e\u003cbr\u003eReplace the shaft when you notice wear, noise, or inconsistent dosing. Regular inspection during maintenance intervals helps prevent failures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this shaft myself?\u003c\/strong\u003e\u003cbr\u003eYes, with basic mechanical skills and following safety precautions, you can replace the shaft. Always disconnect power before servicing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat chemicals is this shaft resistant to?\u003c\/strong\u003e\u003cbr\u003eThe shaft is constructed to resist common chemicals used in water treatment, but always verify compatibility with your specific chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this part require lubrication?\u003c\/strong\u003e\u003cbr\u003eThe shaft is designed to operate within the pump’s sealed environment and typically does not require additional lubrication.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819036725,"sku":"780851339682","price":80.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stucfc5ad.jpg?v=1764174747"},{"product_id":"stqp500-1-collapsible-roller-head-assembly-qp500-1","title":"STQP500-1, Collapsible Roller Head Assembly, QP500-1","description":"\u003cp\u003e\u003cstrong\u003eEnhance Chemical Feed Pump Efficiency with the STQP500-1 Collapsible Roller Head Assembly\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STQP500-1 Collapsible Roller Head Assembly is designed to optimize the performance of your chemical feed pumps by providing a reliable, easy-to-maintain solution for precise chemical dosing. Unlike generic parts, this roller head assembly ensures consistent roller pressure and smooth operation, making it an essential accessory for maintaining your water treatment system’s accuracy and longevity. Engineered specifically for the QP500-1 pump model, this component addresses common wear and tear issues found in chemical feed pumps part and accessories.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eImproves chemical dosing accuracy for better water treatment results\u003c\/li\u003e\n  \u003cli\u003eReduces pump wear by maintaining consistent roller pressure\u003c\/li\u003e\n  \u003cli\u003eEasy to install and replace, minimizing system downtime\u003c\/li\u003e\n  \u003cli\u003eCompact, collapsible design saves space and simplifies maintenance\u003c\/li\u003e\n  \u003cli\u003eDurable construction withstands harsh chemical environments\u003c\/li\u003e\n  \u003cli\u003eEnhances overall pump reliability to protect your system investment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe collapsible roller head assembly is a critical component inside the chemical feed pump, responsible for compressing the tubing as it passes through the pump head. This compression creates a peristaltic action that accurately moves measured amounts of chemical solution through your water treatment system. The rollers rotate smoothly, reducing tubing fatigue and preventing leaks or dosing inconsistencies.\u003c\/p\u003e\n\u003cp\u003eBy maintaining optimal roller pressure and alignment, the STQP500-1 ensures consistent flow rates and precise chemical feed, which is vital for maintaining system balance and water quality in various industrial or municipal applications.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the STQP500-1 Collapsible Roller Head Assembly, you will notice immediate improvements in pump operation, including quieter performance and smoother tubing movement. During the first few weeks, the assembly will settle into optimal function, helping maintain steady chemical dosing without fluctuations.\u003c\/p\u003e\n\u003cp\u003eOver time, the durable materials and design reduce the need for frequent maintenance or roller head replacements, ensuring your chemical feed pump continues to operate efficiently and reliably for the long term.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCollapsible Roller Head Frame\u003c\/strong\u003e – Provides structural support while allowing easy access for tubing changes\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision-Machined Rollers\u003c\/strong\u003e – Ensure smooth, consistent compression and reduce tubing wear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Grade Bearings\u003c\/strong\u003e – Enable quiet roller rotation and long-lasting durability under chemical exposure\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Components\u003c\/strong\u003e – Protect the assembly from chemical damage and extend product life\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off and depressurize the chemical feed pump before starting installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing roller head assembly by loosening mounting screws or clips.\u003c\/li\u003e\n  \u003cli\u003eCarefully detach the tubing from the old roller head, noting its position.\u003c\/li\u003e\n  \u003cli\u003eInstall the STQP500-1 roller head assembly by aligning it with the pump head mount and securing it firmly.\u003c\/li\u003e\n  \u003cli\u003eInsert the tubing into the collapsible roller head, ensuring proper alignment for smooth roller contact.\u003c\/li\u003e\n  \u003cli\u003eRe-pressurize and power on the pump, then observe operation to confirm smooth flow and no leaks.\u003c\/li\u003e\n  \u003cli\u003ePerform routine inspections and clean the roller head as recommended to maintain optimal performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured with precision and quality materials for extended durability in chemical feed applications\u003c\/li\u003e\n  \u003cli\u003eTrusted by water treatment professionals for reliable compatibility with QP500-1 pumps\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically to enhance performance within chemical feed pump systems\u003c\/li\u003e\n  \u003cli\u003eBacked by Water Softener Plus’ commitment to delivering dependable water treatment components\u003c\/li\u003e\n  \u003cli\u003eStreamlines maintenance with a user-friendly, collapsible design that minimizes downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the STQP500-1 compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eThis roller head assembly is specifically designed for the QP500-1 pump model; compatibility with other models is not guaranteed.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the roller head assembly?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on usage and chemical exposure but inspecting the assembly every 6-12 months is recommended for optimal performance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I clean the roller head assembly without removing it?\u003c\/strong\u003e\u003cbr\u003eLight cleaning can be done in place, but thorough maintenance requires removal following the proper safety procedures.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat chemicals is this assembly resistant to?\u003c\/strong\u003e\u003cbr\u003eThe assembly is built with corrosion-resistant materials designed to withstand common water treatment chemicals; however, always verify compatibility with your specific chemicals.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs special training required to install this part?\u003c\/strong\u003e\u003cbr\u003eBasic mechanical skills and adherence to safety protocols are sufficient for installation; consult the pump manual for detailed instructions.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"G.h. Stenner \u0026 Co. Inc.#","offers":[{"title":"Default Title","offer_id":44819819069493,"sku":"780851339695","price":82.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stqp500-1.jpg?v=1764174749"},{"product_id":"stmccp201-5-stenner-1-tube-assm-5-pk-mccp201","title":"STMCCP201-5, Stenner #1 Tube Assm. (5-Pk), MCCP201","description":"\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump Tube Assembly for Consistent Water Treatment Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining your water treatment system, having dependable replacement parts is essential. The STMCCP201-5 Stenner #1 Tube Assembly (5-Pack) offers a trusted solution for chemical feed pumps, designed to ensure efficient and leak-free chemical delivery. This high-quality tube assembly addresses common wear and tear issues, helping you avoid downtime and costly repairs in your water softener or chemical feed setup.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures consistent and accurate chemical dosing to protect your water treatment system’s performance\u003c\/li\u003e\n  \u003cli\u003eReduces the risk of leaks and chemical spills with durable, precision-engineered tubing\u003c\/li\u003e\n  \u003cli\u003eExtends pump lifespan by providing a reliable replacement for worn or damaged tubes\u003c\/li\u003e\n  \u003cli\u003eEasy to install, minimizing system downtime and maintenance effort\u003c\/li\u003e\n  \u003cli\u003ePack of five tubes offers great value and readiness for multiple maintenance cycles\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of Stenner and MCCP201 chemical feed pumps for versatile use\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STMCCP201-5 tube assembly functions as the critical conduit for chemical solutions within your chemical feed pump system. It transports precise volumes of treatment chemicals from the reservoir to your water softener or filtration unit, ensuring proper dosing and system balance. The tube’s design maintains chemical integrity and flow consistency, key factors in preventing system malfunctions and ensuring effective water treatment.\u003c\/p\u003e\n\u003cp\u003eBy replacing worn or degraded tubing, this assembly restores optimal pump operation, allowing the chemical feed pump to maintain steady, accurate chemical injections crucial for system efficiency.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the STMCCP201-5 tube assembly, you will notice smoother, more reliable chemical feed operation with reduced leakage or flow interruptions. In the first few days, your water treatment system will benefit from stabilized chemical dosing, improving overall water quality and system performance.\u003c\/p\u003e\n\u003cp\u003eOver time, this tube assembly’s durable construction supports long-lasting function, reducing the frequency of maintenance and helping you avoid unexpected downtime. Regular replacement as part of your maintenance schedule ensures your chemical feed pump continues to operate at peak efficiency.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-grade chemical-resistant tubing – ensures safe and secure chemical transfer without degradation\u003c\/li\u003e\n  \u003cli\u003ePrecision-cut tube lengths – designed for an exact fit within Stenner and MCCP201 feed pumps\u003c\/li\u003e\n  \u003cli\u003eSecure connectors (pre-installed or compatible) – provide leak-proof joints to maintain system integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve any system pressure.\u003c\/li\u003e\n  \u003cli\u003eRemove the old tube assembly carefully, noting the routing and connections.\u003c\/li\u003e\n  \u003cli\u003eInstall the new STMCCP201-5 tube assembly by connecting both ends securely to the pump fittings.\u003c\/li\u003e\n  \u003cli\u003eCheck that the tube is properly seated with no kinks or bends that could restrict flow.\u003c\/li\u003e\n  \u003cli\u003eTurn the pump back on and observe for any leaks or irregularities.\u003c\/li\u003e\n  \u003cli\u003eRun the system briefly to ensure chemical delivery is consistent and accurate.\u003c\/li\u003e\n  \u003cli\u003eSchedule regular inspections to replace tubes before wear affects performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured with premium materials for chemical resistance and durability under typical water treatment conditions\u003c\/li\u003e\n  \u003cli\u003eTrusted by professionals and water treatment enthusiasts for reliable performance and ease of maintenance\u003c\/li\u003e\n  \u003cli\u003eIdeal fit for Stenner and MCCP201 chemical feed pumps, ensuring compatibility and optimal operation\u003c\/li\u003e\n  \u003cli\u003eProvided in a convenient 5-pack to keep your system running smoothly over time\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this tube assembly compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eThis assembly is specifically designed for Stenner #1 and MCCP201 pumps. Verify your pump model for compatibility before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the tube assembly?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on chemical type and usage but typically every 6–12 months to maintain optimal performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any special precautions during installation?\u003c\/strong\u003e\u003cbr\u003eAlways turn off the pump and relieve pressure before replacing tubing to prevent injury or spills.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this tubing handle all chemical types?\u003c\/strong\u003e\u003cbr\u003eIt is designed for common water treatment chemicals; check compatibility with specific chemicals used in your system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I maintain the tube assembly?\u003c\/strong\u003e\u003cbr\u003eRegularly inspect for cracks, wear, or discoloration and replace immediately if any damage is found.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STMCCP201-5 Stenner #1 Tube Assembly to your cart and keep your chemical feed pump delivering precise, consistent water treatment without interruption.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819135029,"sku":"780851339702","price":168.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/uccp202_1.jpg?v=1764174752"},{"product_id":"sts15n-stenner-sol-tnk-15gal-25-1-4x20-1-2-sts15nc","title":"STS15N, Stenner Sol Tnk, 15gal 25-1\/4x20-1\/2, STS15NC","description":"\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump Tank for Efficient Water Treatment Solutions\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STS15N Stenner Sol Tnk 15gal tank is designed to enhance the performance and safety of your chemical feed pumps and water treatment systems. Unlike standard tanks, it offers superior durability and capacity, ensuring consistent chemical storage and delivery for your water softener or feeding system. This chemical feed pump accessory is a trusted choice for professionals seeking reliable, long-lasting components in their setup.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures stable chemical storage to maintain consistent feed rates\u003c\/li\u003e\n  \u003cli\u003eDurable construction resists corrosion and chemical damage for long-term use\u003c\/li\u003e\n  \u003cli\u003eGenerous 15-gallon capacity reduces refill frequency, saving time and effort\u003c\/li\u003e\n  \u003cli\u003eCompact design (25-1\/4 x 20-1\/2 inches) fits easily into existing water softener setups\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of chemical feed pump systems and accessories\u003c\/li\u003e\n  \u003cli\u003eLightweight yet sturdy build simplifies installation and handling\u003c\/li\u003e\n  \u003cli\u003eProtects your water treatment system by preventing chemical leaks and spills\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STS15N tank serves as a secure reservoir for the chemicals used in water treatment systems, such as those feeding chemical pumps. It stores the solution safely and feeds it steadily into the pump mechanism, ensuring the correct dosage reaches your water softener or filtration unit. This regulated delivery helps maintain system efficiency and water quality.\u003c\/p\u003e\n\u003cp\u003eBy integrating seamlessly with chemical feed pumps, the tank prevents interruptions caused by frequent refills or chemical exposure to external elements, which can degrade system performance over time.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eImmediately after installation, you’ll notice a more streamlined chemical feeding process with fewer manual refills needed thanks to the 15-gallon capacity. The tank’s robust build keeps chemicals safely contained, reducing the risk of leaks or spills during operation.\u003c\/p\u003e\n\u003cp\u003eOver the first few weeks, expect consistent chemical flow rates that support optimal water softening and treatment. With proper maintenance, this tank will provide reliable service for years, requiring only periodic cleaning and inspection to ensure continued performance.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-density polyethylene tank body – provides chemical resistance and durability to withstand harsh water treatment chemicals\u003c\/li\u003e\n  \u003cli\u003eSealed lid with secure locking mechanism – prevents contamination and chemical evaporation\u003c\/li\u003e\n  \u003cli\u003eStandard feed pump connection ports – enable easy integration with your existing chemical feed pump system\u003c\/li\u003e\n  \u003cli\u003eReinforced base – ensures stability and reduces risk of tipping or damage during operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003ePosition the STS15N tank on a stable, level surface near your chemical feed pump setup.\u003c\/li\u003e\n  \u003cli\u003eAttach the tank securely to the feed pump using the standard connection ports.\u003c\/li\u003e\n  \u003cli\u003eFill the tank with the recommended chemical solution, observing all safety guidelines and handling instructions.\u003c\/li\u003e\n  \u003cli\u003eEnsure the lid is tightly sealed to prevent spills or contamination.\u003c\/li\u003e\n  \u003cli\u003eCheck all fittings for leaks and proper alignment before starting your water treatment system.\u003c\/li\u003e\n  \u003cli\u003eMonitor chemical levels regularly and refill as needed to maintain continuous operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt with high-quality materials designed specifically for chemical feed pump applications\u003c\/li\u003e\n  \u003cli\u003eTrusted vendor, Water Softener Plus, known for reliable water treatment components\u003c\/li\u003e\n  \u003cli\u003eOptimized size and weight for easy handling without compromising capacity\u003c\/li\u003e\n  \u003cli\u003eDesigned to integrate smoothly within various water softener and chemical feed pump systems\u003c\/li\u003e\n  \u003cli\u003eEngineered to provide long-term durability and consistent performance in demanding environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this tank compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eThe STS15N is designed to work with most standard chemical feed pumps, but always verify compatibility with your specific pump model before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the tank be cleaned?\u003c\/strong\u003e\u003cbr\u003eRegular inspection and cleaning every few months or according to chemical manufacturer guidelines will help maintain optimal performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the tank handle corrosive chemicals?\u003c\/strong\u003e\u003cbr\u003eThe high-density polyethylene construction offers excellent resistance to many common water treatment chemicals, but check chemical compatibility for highly aggressive substances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating conditions are recommended?\u003c\/strong\u003e\u003cbr\u003eUse the tank within typical water treatment facility temperatures and avoid direct sunlight exposure to prolong material life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs installation difficult for non-professionals?\u003c\/strong\u003e\u003cbr\u003eThe tank is designed for straightforward installation, but if unsure, consult a water treatment professional to ensure safe and proper setup.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this STS15N chemical feed pump tank to your cart and keep your water treatment process flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819495477,"sku":"780851339694","price":520.12,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/sts15n.jpg?v=1764174754"},{"product_id":"stuccp201-stenner-1-tube-assm-2-pk-uccp201","title":"STUCCP201, Stenner #1 Tube Assm. (2 Pk), UCCP201","description":"\u003cp\u003e\u003cstrong\u003eStenner #1 Tube Assembly – Enhance Chemical Feed Pump Performance with Reliable, Durable Components\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining efficient chemical feed pumps, the quality of replacement parts like tube assemblies makes all the difference. The STUCCP201 Stenner #1 Tube Assembly (2 Pack) from Water Softener Plus offers a dependable solution designed specifically for chemical feed pumps and accessories. This assembly ensures smooth, consistent chemical delivery while minimizing downtime, making it an essential upgrade for any water treatment system.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures consistent chemical feed flow for optimal water treatment performance\u003c\/li\u003e\n  \u003cli\u003eReduces risk of leaks or failures with durable, high-quality construction\u003c\/li\u003e\n  \u003cli\u003eEasy-to-install tube assemblies that save time during maintenance\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of Stenner chemical feed pumps and accessories\u003c\/li\u003e\n  \u003cli\u003ePack of two tubes offers convenient replacement supply, minimizing downtime\u003c\/li\u003e\n  \u003cli\u003eLightweight design helps maintain pump efficiency without adding bulk\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STUCCP201 tube assembly serves as a vital component within chemical feed pumps, facilitating the precise movement of treatment chemicals through the system. It connects securely to the pump head, allowing chemicals to flow smoothly and consistently into the water stream without leaks or interruptions.\u003c\/p\u003e\n\u003cp\u003eThis tube assembly is engineered to withstand the chemical exposure and pressure variations typical in water treatment environments, ensuring reliable operation and prolonging the life of your chemical feed pump system.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you’ll immediately notice improved pump operation with steady, uninterrupted chemical feed. Within the first few days, the assembly will settle into your system, maintaining consistent flow without leaks or pressure drops.\u003c\/p\u003e\n\u003cp\u003eOver the longer term, these tube assemblies offer dependable performance with minimal maintenance. Their durable materials resist wear from chemical exposure, reducing the need for frequent replacements and helping keep your water treatment system running smoothly.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision-Molded Tubing –\u003c\/strong\u003e ensures secure, leak-free connections and consistent chemical flow\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChemical-Resistant Material –\u003c\/strong\u003e designed to withstand harsh treatment chemicals without degradation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFlexible Yet Durable Design –\u003c\/strong\u003e accommodates pump movements while maintaining integrity\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePack of Two Tubes –\u003c\/strong\u003e provides immediate spare parts for quick replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing tube assembly carefully, noting the connection points.\u003c\/li\u003e\n  \u003cli\u003eInstall the new STUCCP201 tube assembly by securely attaching it to the pump head and outlet fittings.\u003c\/li\u003e\n  \u003cli\u003eDouble-check all connections for tightness to prevent leaks.\u003c\/li\u003e\n  \u003cli\u003eRestore system pressure and turn the pump back on, monitoring for consistent chemical flow.\u003c\/li\u003e\n  \u003cli\u003eDispose of old tubing according to local guidelines for chemical exposure materials.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to meet high durability standards for extended service life\u003c\/li\u003e\n  \u003cli\u003eTrusted vendor, Water Softener Plus, known for quality water treatment components\u003c\/li\u003e\n  \u003cli\u003eSpecifically designed to fit and perform with Stenner chemical feed pumps and accessories\u003c\/li\u003e\n  \u003cli\u003eOffers cost-effective maintenance by reducing pump downtime and replacement frequency\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this tube assembly compatible with all Stenner pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Stenner #1 style chemical feed pumps; check your model specifications to ensure compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the tube assembly?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on chemical type and usage but generally every 6–12 months or if signs of wear appear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this assembly myself?\u003c\/strong\u003e\u003cbr\u003eYes, installation is straightforward with basic tools, but always follow safety precautions and system shutdown procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any special maintenance requirements?\u003c\/strong\u003e\u003cbr\u003eRegularly inspect the tubing for cracks or leaks and replace promptly to maintain system integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this assembly safe to use with all chemical feed solutions?\u003c\/strong\u003e\u003cbr\u003eThe tubing is made from chemical-resistant materials suitable for most common water treatment chemicals, but verify compatibility with your specific chemicals.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your chemical feed pump’s reliability and efficiency today—add the STUCCP201 Stenner #1 Tube Assembly (2 Pack) to your cart and maintain consistent, leak-free chemical delivery for your water treatment system.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819561013,"sku":"780851339688","price":76.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stuccp201.jpg?v=1764174756"},{"product_id":"stuccp400-stenner-tube-hsng-uccp400","title":"STUCCP400, Stenner Tube Hsng, UCCP400","description":"\u003cp\u003e\u003cstrong\u003eReliable Stenner Tube Housing for Chemical Feed Pumps Enhances System Efficiency and Safety\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STUCCP400 Stenner Tube Housing from Water Softener Plus offers a robust solution for chemical feed pump maintenance and protection. Designed specifically for chemical feed pumps part and accessories, this tube housing ensures secure containment and optimal flow of chemical feeds, reducing the risk of leaks or damage. Its durable construction supports consistent performance in water treatment systems, contributing to safer and more efficient chemical dosing.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eProtects your chemical feed pumps from damage by securely housing the tubing.\u003c\/li\u003e\n  \u003cli\u003eEnhances system reliability by preventing leaks and chemical exposure.\u003c\/li\u003e\n  \u003cli\u003eSupports consistent chemical flow for precise dosing in water treatment applications.\u003c\/li\u003e\n  \u003cli\u003eEasy to install and maintain, reducing downtime and service costs.\u003c\/li\u003e\n  \u003cli\u003eDurable construction withstands typical wear and environmental stresses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STUCCP400 functions as a protective enclosure for the flexible tubing used in chemical feed pumps. By securely housing the tubing, it prevents kinks, abrasions, and exposure to harsh chemicals or environmental factors. This ensures that the chemical feed delivered to your system remains consistent and uninterrupted, which is crucial for maintaining water quality and system balance.\u003c\/p\u003e\n\u003cp\u003eWithin your water treatment setup, the tube housing integrates seamlessly with your dosing pump, providing a stable pathway for chemical feed lines and minimizing the risk of operational failures caused by tubing damage.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you’ll immediately notice improved stability and protection for your chemical feed tubing. In the first days and weeks, this leads to fewer interruptions or leaks, helping maintain consistent chemical dosing. Over time, the durable housing reduces the need for frequent tubing replacements or repairs, supporting long-term system reliability and lowering maintenance efforts.\u003c\/p\u003e\n\u003cp\u003eRegular inspection will ensure the housing remains intact and continues to provide optimal protection, but its sturdy build means it will endure typical wear and tear in most water treatment environments.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-quality tube housing shell\u003c\/strong\u003e – Provides a rigid protective barrier that safeguards tubing from mechanical damage and chemical exposure.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSecure mounting points\u003c\/strong\u003e – Ensure stable attachment to your chemical feed pump setup, preventing unwanted movement or dislodgement.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSealing components\u003c\/strong\u003e – Help maintain leak-free operation by tightly enclosing the chemical feed lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and depressurize the system before installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing tube housing if replacing an old or damaged unit.\u003c\/li\u003e\n  \u003cli\u003ePosition the STUCCP400 tube housing around the chemical feed tubing, ensuring the tubing is properly aligned and free of kinks.\u003c\/li\u003e\n  \u003cli\u003eSecure the housing to the pump using the mounting points, tightening fasteners to prevent movement.\u003c\/li\u003e\n  \u003cli\u003eCheck all seals and connections to confirm a leak-free fit.\u003c\/li\u003e\n  \u003cli\u003eRestore system pressure and power, then monitor for proper chemical flow and housing stability.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt from durable materials designed specifically for chemical feed pump applications, ensuring long-lasting protection.\u003c\/li\u003e\n  \u003cli\u003eOffered by Water Softener Plus, a trusted provider specializing in water treatment components and accessories.\u003c\/li\u003e\n  \u003cli\u003ePrecisely engineered to fit a range of Stenner chemical feed pumps, improving compatibility and ease of use.\u003c\/li\u003e\n  \u003cli\u003eEnhances safety by minimizing chemical exposure risks during pump operation and maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the STUCCP400 compatible with all Stenner chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed to fit most common Stenner pumps requiring tube housing, but always verify your pump model for optimal compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I inspect or replace the tube housing?\u003c\/strong\u003e\u003cbr\u003eRegular inspections are recommended during routine maintenance; replacement depends on wear but typically occurs when damage or leaks are observed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the tube housing myself?\u003c\/strong\u003e\u003cbr\u003eYes, installation is straightforward with basic tools, but always follow safety precautions and turn off your system before beginning.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the housing resistant to chemical corrosion?\u003c\/strong\u003e\u003cbr\u003eYes, it is made from materials selected to withstand exposure to typical chemical feeds used in water treatment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this product require special cleaning?\u003c\/strong\u003e\u003cbr\u003eCleaning with mild detergents during regular maintenance is sufficient; avoid harsh chemicals that could degrade the housing material.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STUCCP400 Stenner Tube Housing to your cart and keep your chemical feed pumps protected and your water treatment operation running smoothly.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819692085,"sku":"780851339684","price":75.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stuccp400.jpg?v=1764174760"},{"product_id":"stucmacwo-stenner-weight-strainr-1-4-st114","title":"STUCMACWO, Stenner Weight \u0026 Strainr 1\/4, ST114","description":"\u003cp\u003e\u003cstrong\u003eSTUCMACWO Stenner Weight \u0026amp; Strainr 1\/4 – Enhance Chemical Feed Pump Efficiency and System Longevity\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining optimal performance in your chemical feed pumps, the STUCMACWO Stenner Weight \u0026amp; Strainr 1\/4 offers a reliable and precise solution. Designed specifically for water treatment systems, this accessory helps regulate chemical feed flow while protecting your equipment from strain and damage. As a trusted part under the Chemical Feed Pumps Part and Accessories category, it ensures your water softener or treatment setup operates smoothly and efficiently.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eImproves chemical feed accuracy to optimize water treatment results\u003c\/li\u003e\n  \u003cli\u003eProtects pump components by reducing mechanical strain and wear\u003c\/li\u003e\n  \u003cli\u003eDurable construction built to withstand continuous operation in demanding environments\u003c\/li\u003e\n  \u003cli\u003eEasy to install and compatible with a wide range of Stenner chemical feed pumps\u003c\/li\u003e\n  \u003cli\u003eHelps maintain consistent flow rates, reducing system downtime and maintenance needs\u003c\/li\u003e\n  \u003cli\u003eLightweight design minimizes added stress on your pump assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STUCMACWO Stenner Weight \u0026amp; Strainr 1\/4 functions as a balancing component within your chemical feed pump system. By applying a calibrated weight, it counteracts the natural strain placed on pump mechanisms during operation. This helps stabilize the pumping action, ensuring a steady chemical feed rate. Additionally, the strainr component filters out excess pressure and vibration, minimizing wear on delicate pump parts.\u003c\/p\u003e\n\u003cp\u003eInstalled directly onto compatible Stenner pumps, it integrates seamlessly with your existing water softener or treatment equipment, enhancing overall system reliability and performance.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eUpon installation, you’ll notice improved stability in your chemical feed pump’s operation, with smoother and more consistent chemical dosing. In the first days and weeks, this translates to enhanced water treatment effectiveness and fewer fluctuations in chemical concentration.\u003c\/p\u003e\n\u003cp\u003eOver the longer term, the strainr’s protective function reduces mechanical stress, contributing to extended pump lifespan and less frequent maintenance interventions. This means fewer unexpected interruptions and more dependable system performance.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePrecision weight – calibrated to balance pump strain and optimize feed consistency\u003c\/li\u003e\n  \u003cli\u003eRobust strainr housing – engineered to absorb mechanical vibrations and protect pump components\u003c\/li\u003e\n  \u003cli\u003eCorrosion-resistant materials – ensuring durability even in harsh chemical environments\u003c\/li\u003e\n  \u003cli\u003eStandard 1\/4” fittings – for easy integration with most Stenner chemical feed pumps\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off your chemical feed pump and depressurize the system before installation.\u003c\/li\u003e\n  \u003cli\u003eRemove any existing weight or strainr components from the pump assembly.\u003c\/li\u003e\n  \u003cli\u003eAttach the STUCMACWO Stenner Weight \u0026amp; Strainr 1\/4 to the designated mounting point, ensuring a secure fit.\u003c\/li\u003e\n  \u003cli\u003eReconnect any fittings or lines as needed, verifying that all connections are tight and leak-free.\u003c\/li\u003e\n  \u003cli\u003eRestart the pump and observe the operation to confirm stable chemical feed and absence of excessive vibration.\u003c\/li\u003e\n  \u003cli\u003eSchedule routine inspections as part of your system maintenance to ensure ongoing performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured with high-quality materials to endure continuous use in chemical environments\u003c\/li\u003e\n  \u003cli\u003eBacked by Water Softener Plus, a trusted vendor specializing in water treatment components\u003c\/li\u003e\n  \u003cli\u003eSpecifically designed to fit and enhance Stenner chemical feed pumps, ensuring compatibility\u003c\/li\u003e\n  \u003cli\u003eContributes to longer pump life and reduced maintenance costs over time\u003c\/li\u003e\n  \u003cli\u003eLightweight yet robust design minimizes additional load on your system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this weight and strainr compatible with all Stenner pumps?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most Stenner chemical feed pumps that accept a 1\/4” weight and strainr component. Check your pump model specifications for confirmation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should I inspect or replace this component?\u003c\/strong\u003e\u003cbr\u003eRegular inspection every 6-12 months is recommended, with replacement as needed based on wear or damage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I install this myself or do I need a professional?\u003c\/strong\u003e\u003cbr\u003eInstallation is straightforward and can be done by a knowledgeable user following safety precautions, but professional assistance is advised if unsure.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes this component affect chemical feed rates?\u003c\/strong\u003e\u003cbr\u003eYes, it stabilizes and improves the consistency of chemical feed rates but does not directly increase or decrease dosage.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAre there any special operating conditions to consider?\u003c\/strong\u003e\u003cbr\u003eEnsure the component is used within the pump’s recommended pressure and chemical compatibility ranges to avoid damage.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819757621,"sku":"780851339679","price":46.86,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stucmacwo.jpg?v=1764174763"},{"product_id":"stuccp207-2-stenner-7-tube-assm-2-pk-uccp207","title":"STUCCP207-2, Stenner #7 Tube Assm. (2-Pk), UCCP207","description":"\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump Tube Assembly for Consistent Water Treatment Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining optimal chemical feed pump operation, the STUCCP207-2 Stenner #7 Tube Assembly (2-Pk) from Water Softener Plus stands out as a dependable solution. Designed specifically for chemical feed pumps, this tube assembly addresses the common challenges of wear and chemical exposure, providing a durable and efficient replacement part that keeps your water treatment system running smoothly.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures consistent chemical dosing for precise water treatment control\u003c\/li\u003e\n  \u003cli\u003eResists chemical corrosion and wear, extending component lifespan\u003c\/li\u003e\n  \u003cli\u003eEasy to install, minimizing downtime and maintenance effort\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner #7 pumps, ensuring seamless integration\u003c\/li\u003e\n  \u003cli\u003ePackaged in a convenient 2-pack to keep spare tubes on hand\u003c\/li\u003e\n  \u003cli\u003eImproves pump reliability, reducing system interruptions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STUCCP207-2 tube assembly functions as a critical conduit within your chemical feed pump, delivering precise volumes of treatment chemicals into your water system. The flexible tubing is engineered to withstand chemical exposure while maintaining optimal flow rates. When installed, it works in tandem with the pump’s motor and diaphragm to ensure accurate, consistent chemical feed, essential for effective water softening or conditioning.\u003c\/p\u003e\n\u003cp\u003eThis tube assembly’s design helps maintain system pressure and prevents leaks or blockages that could interrupt chemical dosing, ultimately supporting your water treatment system’s overall efficiency and longevity.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the STUCCP207-2 tube assembly, you can immediately notice smoother pump operation and reliable chemical delivery. In the first few days, the tube will conform to your system’s flow requirements, helping maintain steady dosing without fluctuations. Over weeks and months, the durable construction ensures resistance to cracking, swelling, or chemical degradation that often cause failures in standard tubes.\u003c\/p\u003e\n\u003cp\u003eRegular inspection and timely replacement of these tubes will help you avoid unexpected pump downtime and maintain consistent water treatment performance.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eStenner #7 Tube Assembly – crafted from chemical-resistant material to handle aggressive feed solutions\u003c\/li\u003e\n  \u003cli\u003ePrecision fittings – designed for secure connections to prevent leaks and maintain consistent pressure\u003c\/li\u003e\n  \u003cli\u003eDual pack configuration – provides an immediate replacement and a spare to ensure uninterrupted system operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before starting.\u003c\/li\u003e\n  \u003cli\u003eRemove the old tubing by disconnecting it from the pump fittings carefully.\u003c\/li\u003e\n  \u003cli\u003eInstall the new STUCCP207-2 tube assembly by firmly attaching both ends to the corresponding pump connectors.\u003c\/li\u003e\n  \u003cli\u003eEnsure all fittings are tight and secure to prevent leaks.\u003c\/li\u003e\n  \u003cli\u003eRestore power and system pressure, then check for proper chemical flow and absence of leaks.\u003c\/li\u003e\n  \u003cli\u003eMonitor operation for a short period to confirm stable dosing performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured with high-quality, chemical-resistant materials to maximize durability\u003c\/li\u003e\n  \u003cli\u003eTrusted vendor Water Softener Plus offers reliable components for water treatment systems\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for Stenner #7 pumps, ensuring optimal fit and function\u003c\/li\u003e\n  \u003cli\u003eSupports long-term system efficiency with minimal maintenance requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this tube assembly compatible with all Stenner pumps?\u003c\/strong\u003e\u003cbr\u003eIt is specifically designed for Stenner #7 chemical feed pumps; compatibility with other models may vary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the tube assembly?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on chemical exposure and usage but generally should be inspected every 6-12 months.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this tube assembly myself?\u003c\/strong\u003e\u003cbr\u003eYes, installation is straightforward with basic tools and can be safely completed by following the provided steps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat chemicals is this tube assembly resistant to?\u003c\/strong\u003e\u003cbr\u003eIt is engineered to withstand a variety of common water treatment chemicals; always verify compatibility with your specific chemical solutions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any special storage requirements?\u003c\/strong\u003e\u003cbr\u003eStore the tubes in a cool, dry place away from direct sunlight to maintain material integrity before use.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STUCCP207-2 Stenner #7 Tube Assembly (2-Pk) to your cart and keep your water treatment system flowing clean and consistent with precision chemical dosing.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819790389,"sku":"780851339685","price":76.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stuccp207.jpg?v=1764174765"},{"product_id":"stuccp100-stenner-tube-hsng-cover-w-bushing-uccp100","title":"STUCCP100, Stenner Tube Hsng Cover W\/Bushing, UCCP100","description":"\u003cp\u003e\u003cstrong\u003eSTUCCP100 Stenner Tube Housing Cover with Bushing: Enhance Your Chemical Feed Pump Protection and Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining chemical feed pumps, having reliable components like the STUCCP100 Stenner Tube Housing Cover with Bushing is essential. This part is designed to improve the durability and operational efficiency of your water treatment system by providing a secure, leak-resistant seal. Built specifically for chemical feed pumps, this housing cover helps prevent common issues such as leaks and premature wear, ensuring your system runs smoothly with minimal downtime.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eProtects your chemical feed pump from leaks and contamination, preserving system integrity\u003c\/li\u003e\n  \u003cli\u003eEnhances the durability of pump tubing by providing a secure, stable housing cover\u003c\/li\u003e\n  \u003cli\u003eFacilitates easy installation and maintenance, saving you time and effort\u003c\/li\u003e\n  \u003cli\u003eImproves overall pump efficiency by maintaining optimal tube alignment and function\u003c\/li\u003e\n  \u003cli\u003eCompatible with a range of Stenner pump models, ensuring versatile use in water softener and treatment setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STUCCP100 functions as a protective cover that securely holds the pump tube in place within the chemical feed pump assembly. The integrated bushing reduces wear on the tubing by minimizing movement and friction during pump operation. This protection is crucial because the tubing is the conduit for chemical injection, and any damage or misalignment can lead to leaks or inconsistent dosing.\u003c\/p\u003e\n\u003cp\u003eBy ensuring the tube stays properly seated and protected, this cover helps maintain consistent chemical feed rates, which is vital for effective water treatment and system performance.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eUpon installation, you will notice a tighter, more secure fit around your pump tubing, reducing the risk of leaks or tube slippage. During the first days and weeks of use, the cover will help stabilize the tubing, contributing to smoother pump operation and consistent chemical delivery.\u003c\/p\u003e\n\u003cp\u003eOver the long term, the STUCCP100’s durable construction means you can expect fewer maintenance interruptions and extended tubing life, reducing replacement frequency and helping keep your system running reliably.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eStenner Tube Housing Cover – Provides a robust, protective enclosure for the pump tube to prevent damage and leaks\u003c\/li\u003e\n  \u003cli\u003eBushing Insert – Reduces friction and wear on the tubing, ensuring smooth operation and longer tube life\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the pump and disconnect power to ensure safety during installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing tube housing cover from your Stenner chemical feed pump.\u003c\/li\u003e\n  \u003cli\u003eInspect the pump tubing for wear or damage and replace if necessary.\u003c\/li\u003e\n  \u003cli\u003ePlace the STUCCP100 housing cover with bushing over the pump tubing, ensuring the bushing seats properly around the tube.\u003c\/li\u003e\n  \u003cli\u003eSecure the housing cover in place according to your pump model’s specifications.\u003c\/li\u003e\n  \u003cli\u003eReconnect power and test the pump to confirm proper installation and leak-free operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to high-quality standards ensuring long-lasting durability in demanding chemical feed environments\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for Stenner pumps, guaranteeing a perfect fit and optimal performance\u003c\/li\u003e\n  \u003cli\u003eTrusted by water treatment professionals for reliability and ease of maintenance\u003c\/li\u003e\n  \u003cli\u003eSupports efficient chemical dosing, essential for maintaining water softener and treatment system effectiveness\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the STUCCP100 compatible with all Stenner chemical feed pump models?\u003c\/strong\u003e\u003cbr\u003eIt is designed to fit a wide range of Stenner pumps, but please check your specific model compatibility before purchasing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the tube housing cover?\u003c\/strong\u003e\u003cbr\u003eReplacement depends on usage and chemical exposure, but inspecting it during regular maintenance and replacing when signs of wear appear is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this cover myself?\u003c\/strong\u003e\u003cbr\u003eYes, installation is straightforward with basic tools, but always ensure the pump is powered off before starting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the bushing require lubrication?\u003c\/strong\u003e\u003cbr\u003eNo lubrication is needed; the bushing is made from materials engineered to minimize friction naturally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this part resistant to common chemicals used in water treatment?\u003c\/strong\u003e\u003cbr\u003eYes, the materials selected are compatible with typical chemical feed solutions to ensure longevity.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STUCCP100 Stenner Tube Housing Cover with Bushing to your cart and keep your chemical feed pump operating cleanly, efficiently, and consistently.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819921461,"sku":"780851339689","price":55.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stuccp100.jpg?v=1764174771"},{"product_id":"sthpack-2-stenner-1-4-accessory-kit-2-tube-hpack-2","title":"STHPACK-2, Stenner 1\/4 Accessory Kit, #2 Tube, HPACK-2","description":"\u003cp\u003e\u003cstrong\u003eSTHPACK-2 Stenner 1\/4 Accessory Kit: Ensure Precise Chemical Feed Pump Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STHPACK-2 accessory kit is designed to enhance the reliability and efficiency of your chemical feed pumps in water treatment systems. Unlike generic kits, this Stenner 1\/4 accessory kit includes essential components tailored to fit #2 tubing, ensuring optimal pump operation and reducing downtime. If you rely on chemical feed pumps part and accessories for system maintenance, this kit provides a dependable, easy-to-install solution that keeps your water softener or treatment setup running smoothly.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures accurate chemical dosing by maintaining proper tubing connection\u003c\/li\u003e\n  \u003cli\u003eEnhances pump longevity through secure and leak-resistant fittings\u003c\/li\u003e\n  \u003cli\u003eReduces system downtime with easy installation and reliable components\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner #2 tubing for precise fit and function\u003c\/li\u003e\n  \u003cli\u003eSupports consistent water treatment performance by preventing leaks and blockages\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STHPACK-2 accessory kit serves as a critical interface between your chemical feed pump and the tubing that delivers treatment chemicals into your water system. By providing secure fittings and connectors designed specifically for Stenner #2 tubing, it ensures a tight seal that prevents leaks and maintains consistent chemical flow. This reliable connection supports accurate dosing and helps your system maintain optimal water treatment efficiency.\u003c\/p\u003e\n\n\u003cp\u003eWhen installed, the kit components guide chemical solutions safely from the pump through the tubing, avoiding disruptions caused by loose or incompatible parts. This smooth chemical feed is essential for water softeners and other treatment systems that depend on precise chemical injection for effectiveness.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you will notice immediate improvement in the stability and reliability of your chemical feed pump operation. The secure tubing connections minimize leaks, reducing the need for frequent adjustments or repairs. Within the first few days, your system will maintain a steady chemical flow, improving overall water treatment consistency.\u003c\/p\u003e\n\n\u003cp\u003eOver the longer term, this kit’s durable components help extend the lifespan of your pump assembly by preventing wear caused by poor connections or chemical exposure. Routine inspections and occasional replacement of tubing will keep your system running efficiently without unexpected interruptions.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eStenner 1\/4\" tubing connectors – ensure a precise, leak-proof connection to #2 tubing\u003c\/li\u003e\n  \u003cli\u003eSecure fittings – enhance chemical feed pump performance by preventing disconnections\u003c\/li\u003e\n  \u003cli\u003eDurable tubing segments – designed to resist chemical degradation and maintain flow integrity\u003c\/li\u003e\n  \u003cli\u003eInstallation hardware – included for quick and secure attachment to your existing pump setup\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off your chemical feed pump and relieve system pressure before installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing tubing or fittings from the pump and tubing connection points.\u003c\/li\u003e\n  \u003cli\u003eAttach the Stenner 1\/4\" tubing connectors to the #2 tubing, ensuring a snug fit.\u003c\/li\u003e\n  \u003cli\u003eSecure the connectors and fittings according to the included hardware instructions.\u003c\/li\u003e\n  \u003cli\u003eCheck all connections for tightness to prevent leaks.\u003c\/li\u003e\n  \u003cli\u003eTurn the pump back on and observe the chemical feed line for proper flow and no leaks.\u003c\/li\u003e\n  \u003cli\u003ePerform routine checks during operation to ensure continued performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-quality components specifically designed for Stenner chemical feed pumps and #2 tubing\u003c\/li\u003e\n  \u003cli\u003eBuilt to withstand harsh chemical environments common in water treatment applications\u003c\/li\u003e\n  \u003cli\u003eReliable vendor support from Water Softener Plus, a trusted name in water treatment parts\u003c\/li\u003e\n  \u003cli\u003eEasy integration into existing systems with minimal downtime and hassle\u003c\/li\u003e\n  \u003cli\u003eOptimized for consistency in chemical dosing, improving overall system effectiveness\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this kit compatible with all Stenner pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed specifically for Stenner pumps using #2 tubing and 1\/4\" fittings; verify your model matches these specifications before purchasing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the tubing included in the kit?\u003c\/strong\u003e\u003cbr\u003eRegular inspection is recommended; replace tubing as needed based on chemical exposure and wear, typically every 6–12 months.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I install the kit myself?\u003c\/strong\u003e\u003cbr\u003eYes, the kit is designed for straightforward installation with basic tools, but always follow safety precautions and manufacturer instructions.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAre the fittings resistant to common water treatment chemicals?\u003c\/strong\u003e\u003cbr\u003eYes, the materials used are selected to resist degradation from typical chemicals used in water softening and treatment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should I do if I notice leaks after installation?\u003c\/strong\u003e\u003cbr\u003eTurn off the pump immediately, check all connections for tightness, and replace any damaged components before resuming operation.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819819986997,"sku":"780851339707","price":100.94,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/sthpack-2.jpg?v=1764174772"},{"product_id":"stmccp207-5-stenner-7-tube-pack-of-5-mccp207","title":"STMCCP207-5, Stenner #7 Tube, Pack of 5, MCCP207","description":"\u003cp\u003e\u003cstrong\u003eSTMCCP207-5 Stenner #7 Tube: Reliable Chemical Feed Pump Tubing for Consistent Water Treatment Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining optimal water treatment systems, the quality and durability of chemical feed pump parts matter. The STMCCP207-5 Stenner #7 Tube pack of 5 is engineered to deliver reliable, leak-free performance, ensuring your chemical feed pumps operate efficiently and safely. Designed specifically as a replacement tube for Stenner chemical feed pumps, this accessory helps prevent downtime and maintain consistent chemical dosing in your water softener or treatment setup.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures precise chemical dosing for effective water treatment\u003c\/li\u003e\n  \u003cli\u003eDurable construction resists wear and chemical corrosion over time\u003c\/li\u003e\n  \u003cli\u003eEasy installation reduces maintenance time and system downtime\u003c\/li\u003e\n  \u003cli\u003ePack of 5 tubes provides convenient replacements to keep your system running smoothly\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner #7 pumps, ensuring a perfect fit and reliable operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STMCCP207-5 tube functions as the essential conduit for chemical solution transfer within Stenner #7 chemical feed pumps. It carries the chemical from the pump’s reservoir through the pump head and into your water treatment system, allowing for accurate and controlled chemical injection. Constructed from materials that withstand chemical exposure, this tube ensures the chemical feed process remains uninterrupted and precise.\u003c\/p\u003e\n\u003cp\u003eBy maintaining a secure and leak-resistant flow path, the tube supports the pump’s ability to deliver consistent chemical dosing, which is critical for effective water softening and conditioning processes.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the STMCCP207-5 tube, you will notice a secure seal that prevents leaks and chemical loss, providing peace of mind during operation. In the first days and weeks, the tube will maintain consistent chemical flow rates, supporting your system’s optimal performance. Over time, expect long-lasting durability with minimal maintenance, as the tube resists common wear and chemical degradation, reducing the need for frequent replacements.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStenner #7 Replacement Tube\u003c\/strong\u003e – Engineered for chemical feed pumps to ensure compatibility and precise chemical flow.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChemical-Resistant Material\u003c\/strong\u003e – Prevents degradation and extends tube life in harsh chemical environments.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePack of 5 Tubes\u003c\/strong\u003e – Provides multiple replacements to support ongoing system reliability without interruptions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the old or damaged tube by carefully detaching it from the pump head and reservoir connections.\u003c\/li\u003e\n  \u003cli\u003eInsert the new STMCCP207-5 tube firmly into the pump head and reservoir fittings, ensuring secure connections on both ends.\u003c\/li\u003e\n  \u003cli\u003eCheck for proper seating to avoid leaks and ensure tightness without over-tightening.\u003c\/li\u003e\n  \u003cli\u003eRestore system pressure and turn the pump on to verify smooth chemical flow through the new tube.\u003c\/li\u003e\n  \u003cli\u003eInspect for leaks during initial operation and adjust connections if necessary.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to strict quality standards for durability and chemical resistance\u003c\/li\u003e\n  \u003cli\u003eTrusted by water treatment professionals for compatibility with Stenner chemical feed pumps\u003c\/li\u003e\n  \u003cli\u003eDesigned to support efficient and accurate chemical dosing for water softening and treatment systems\u003c\/li\u003e\n  \u003cli\u003eVendor Water Softener Plus specializes in chemical feed pump parts, ensuring expert product support\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this tube compatible with all Stenner chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eThis tube is specifically designed for Stenner #7 pumps; please verify your pump model before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the tube?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on chemical type and usage, but inspecting the tube every 6–12 months is recommended for optimal performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this tube with chemicals other than those recommended by Stenner?\u003c\/strong\u003e\u003cbr\u003eIt is best to use chemicals compatible with the tube material to prevent premature wear or damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance does the tube require?\u003c\/strong\u003e\u003cbr\u003eRegular inspection for cracks, leaks, or wear is important; replace immediately if any damage is detected.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any safety precautions during installation?\u003c\/strong\u003e\u003cbr\u003eAlways shut off the pump and relieve pressure before replacing the tube to avoid chemical exposure or injury.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STMCCP207-5 Stenner #7 Tube pack of 5 to your cart and keep your water flowing clean and consistent with precise chemical feed performance.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820019765,"sku":"780851339700","price":168.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stmccp207-5.jpg?v=1764174774"},{"product_id":"stmp90000-stenner-pump-rain-roof-mp90000","title":"STMP90000, Stenner Pump Rain Roof, MP90000","description":"\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump for Efficient Water Treatment – The STMP90000 Stenner Pump Rain Roof\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining optimal water quality and system performance, the STMP90000 Stenner Pump Rain Roof offers a dependable solution designed specifically for chemical feed pumps and accessories. This pump addresses common challenges in water treatment systems by providing consistent dosing and protection against environmental factors. Engineered for durability and precision, it ensures your water softener or treatment setup runs smoothly with minimal maintenance.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures precise chemical dosing for consistent water treatment results\u003c\/li\u003e\n  \u003cli\u003eProtects pump components from rain and weather exposure with its durable rain roof design\u003c\/li\u003e\n  \u003cli\u003eReduces maintenance frequency by shielding critical parts from environmental damage\u003c\/li\u003e\n  \u003cli\u003eEnhances system longevity through reliable, steady pump operation\u003c\/li\u003e\n  \u003cli\u003eLightweight and easy to install, minimizing downtime during replacement or upgrades\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of chemical feed pumps and accessories for versatile use\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STMP90000 Stenner Pump Rain Roof functions as a protective cover that shields your chemical feed pump from rain, dust, and other environmental elements. By preventing moisture and debris from reaching the pump’s sensitive parts, it helps maintain consistent pump performance and accurate chemical dosing. This is crucial in water softener and treatment systems where precise chemical feed ensures effective water quality management.\u003c\/p\u003e\n\u003cp\u003eInstalled over the pump, the rain roof allows for ventilation while safeguarding the internal components. This balance prevents overheating and corrosion, which can degrade pump efficiency and lifespan.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eImmediately after installing the STMP90000, you’ll notice enhanced protection of your chemical feed pump, reducing the risk of weather-related damage. In the first few days and weeks, the pump should maintain a steady flow rate without interruption, ensuring your water treatment process remains uninterrupted.\u003c\/p\u003e\n\u003cp\u003eOver the long term, the rain roof contributes to reduced maintenance needs and fewer component replacements. Its robust design supports consistent chemical feed dosing, helping your system operate reliably even in challenging outdoor environments.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eDurable Rain Roof Housing – crafted to shield the pump from rain and environmental debris\u003c\/li\u003e\n  \u003cli\u003eVentilation Slots – designed to allow airflow, preventing heat buildup inside the pump enclosure\u003c\/li\u003e\n  \u003cli\u003eLightweight Construction – easy to handle and install without adding unnecessary weight to the system\u003c\/li\u003e\n  \u003cli\u003eSecure Mounting Brackets – ensure stable attachment to various chemical feed pump models\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off your water treatment system and disconnect power to the chemical feed pump for safety.\u003c\/li\u003e\n  \u003cli\u003eRemove any existing cover or housing from the pump if applicable.\u003c\/li\u003e\n  \u003cli\u003ePosition the STMP90000 rain roof over the pump, aligning the mounting brackets with the pump’s frame.\u003c\/li\u003e\n  \u003cli\u003eSecure the rain roof using the included hardware or compatible fasteners, ensuring a snug fit.\u003c\/li\u003e\n  \u003cli\u003eCheck that ventilation slots are unobstructed to maintain airflow.\u003c\/li\u003e\n  \u003cli\u003eRestore power and restart the water treatment system, monitoring for normal pump operation.\u003c\/li\u003e\n  \u003cli\u003ePerform regular inspections to ensure the rain roof remains securely in place and free of debris.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eConstructed with high-quality materials for long-lasting durability in outdoor environments\u003c\/li\u003e\n  \u003cli\u003eDesigned by Water Softener Plus, a trusted name in chemical feed pump parts and accessories\u003c\/li\u003e\n  \u003cli\u003eSpecifically tailored to complement a variety of water treatment systems and chemical feed pumps\u003c\/li\u003e\n  \u003cli\u003eLightweight and user-friendly, making installation and maintenance straightforward\u003c\/li\u003e\n  \u003cli\u003eOffers excellent value by extending pump life and reducing repair costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the STMP90000 compatible with all Stenner chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed to fit most Stenner pump models, but please verify compatibility with your specific pump before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I inspect the rain roof?\u003c\/strong\u003e\u003cbr\u003eRegular inspections every 3 to 6 months are recommended to clear any debris and ensure the roof remains secure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the rain roof be installed outdoors in all weather conditions?\u003c\/strong\u003e\u003cbr\u003eYes, it is built to withstand typical outdoor weather including rain and sun exposure, protecting your pump effectively.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the rain roof affect pump ventilation or cause overheating?\u003c\/strong\u003e\u003cbr\u003eNo, the ventilation slots are specifically designed to allow airflow and prevent heat buildup inside the pump enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs installation complicated for someone without technical experience?\u003c\/strong\u003e\u003cbr\u003eThe installation process is straightforward and can be completed by most users following the provided steps safely.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STMP90000 Stenner Pump Rain Roof to your cart and keep your water treatment system protected, efficient, and running smoothly.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820085301,"sku":"780851339696","price":48.6,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stmp90000.jpg?v=1764174775"},{"product_id":"stucfc5ho-stenner-variable-cam-2-pk-ucfc5h0","title":"STUCFC5HO, Stenner Variable Cam (2 Pk), UCFC5H0","description":"\u003cp\u003e\u003cstrong\u003eStenner Variable Cam (2 Pk) for Chemical Feed Pumps – Enhance Pump Efficiency and Precision\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eUnlike standard fixed cams, the STUCFC5HO Stenner Variable Cam set offers adjustable performance tailored to the demands of your chemical feed pumps. Designed specifically for water treatment systems, these variable cams provide reliable, precise control over pump stroke length, ensuring optimal chemical dosing and system efficiency. Whether upgrading or replacing worn parts, this 2-pack solution supports consistent operation in chemical feed pumps and accessories.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eImproves chemical dosing accuracy for better water treatment results\u003c\/li\u003e\n  \u003cli\u003eExtends pump component life by reducing wear through adjustable stroke control\u003c\/li\u003e\n  \u003cli\u003eEnsures consistent feed rates, minimizing system downtime and maintenance\u003c\/li\u003e\n  \u003cli\u003eFacilitates easy installation and replacement with compatible Stenner pump models\u003c\/li\u003e\n  \u003cli\u003eSupports dual-cam setups for balanced pump operation and reduced vibration\u003c\/li\u003e\n  \u003cli\u003eMade from durable materials designed to withstand chemical exposure and mechanical stress\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe Stenner Variable Cam fits onto the camshaft of compatible chemical feed pumps, controlling the pump’s stroke length by adjusting the cam profile. This variable adjustment modulates the movement of the pump’s diaphragm, directly influencing the volume of chemical solution dispensed with each cycle. By customizing the stroke, operators can fine-tune feed rates to match system requirements precisely.\u003c\/p\u003e\n\u003cp\u003eThis adaptability is crucial in water softener and treatment systems, where chemical dosing must be both accurate and consistent to maintain water quality and system protection. The dual-pack design allows for simultaneous use in pumps requiring paired cams for balanced operation.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you’ll notice smoother pump operation with reduced mechanical noise and vibration. Chemical feed rates will become more predictable, helping to stabilize your water treatment process immediately. Over the first few days, minor adjustments to the cam settings may be needed to dial in optimal dosing.\u003c\/p\u003e\n\u003cp\u003eLong-term, the variable cams are engineered for durability and will maintain performance without frequent replacements, reducing maintenance efforts. Regular inspection during routine system checks will ensure continued reliable operation.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo variable cams – designed for precise stroke length adjustment in Stenner chemical feed pumps\u003c\/li\u003e\n  \u003cli\u003eHigh-grade polymer construction – resists chemical corrosion and mechanical wear\u003c\/li\u003e\n  \u003cli\u003ePrecision-machined cam surfaces – ensure smooth diaphragm movement and consistent feed volume\u003c\/li\u003e\n  \u003cli\u003eCompatibility with UCFC5H0 series pumps – ensures seamless integration with your existing system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and disconnect power to ensure safety.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing cams by loosening the retaining screws on the camshaft.\u003c\/li\u003e\n  \u003cli\u003eInstall the new variable cams onto the camshaft, aligning them properly for your target stroke length.\u003c\/li\u003e\n  \u003cli\u003eTighten the retaining screws securely without over-torquing.\u003c\/li\u003e\n  \u003cli\u003eReconnect power and run the pump at low speed to observe operation and adjust cam position if necessary.\u003c\/li\u003e\n  \u003cli\u003ePerform chemical feed rate checks and fine-tune the cams to achieve desired dosing accuracy.\u003c\/li\u003e\n  \u003cli\u003eSchedule routine inspections to monitor cam wear and maintain optimal performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to high-quality standards for consistent, long-lasting pump performance\u003c\/li\u003e\n  \u003cli\u003eTrusted by water treatment professionals and compatible with popular Stenner pump models\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for chemical feed pump applications, ensuring precise and reliable dosing\u003c\/li\u003e\n  \u003cli\u003eOffers excellent chemical resistance to maintain integrity in harsh operating environments\u003c\/li\u003e\n  \u003cli\u003eBacked by Water Softener Plus’s commitment to dependable water treatment components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this cam compatible with all Stenner chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with UCFC5H0 series pumps and similar models; always verify your pump model before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I inspect or replace the variable cams?\u003c\/strong\u003e\u003cbr\u003eInspect cams during regular maintenance intervals; replace if you notice wear or inconsistent dosing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I adjust the cams while the pump is running?\u003c\/strong\u003e\u003cbr\u003eAdjustments should be made only when the pump is off to prevent damage and ensure safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre these cams resistant to all types of chemicals?\u003c\/strong\u003e\u003cbr\u003eThey are made from materials resistant to most common water treatment chemicals but avoid exposure to unsupported substances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill installing these cams affect my pump’s warranty?\u003c\/strong\u003e\u003cbr\u003eUsing manufacturer-approved parts like these cams generally maintains warranty validity—check your specific pump warranty terms.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your pump’s dosing precision and durability today—add the STUCFC5HO Stenner Variable Cam 2-pack to your cart and ensure your chemical feed pumps operate smoothly and reliably.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820118069,"sku":"780851339681","price":48.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stucfc5ho.jpg?v=1764174776"},{"product_id":"stucak100-stenner-conn-nut-1-4-10-pk-ucak100","title":"STUCAK100, Stenner Conn Nut, 1\/4 (10 Pk), UCAK100","description":"\u003cp\u003e\u003cstrong\u003eReliable Stenner Connection Nut 1\/4” – Secure Your Chemical Feed Pump with Ease\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining your water treatment system, secure and leak-free connections are essential. The STUCAK100 Stenner Conn Nut 1\/4” (10 Pack) offers a dependable solution designed specifically for chemical feed pumps and accessories. This connection nut ensures a tight, durable fit that reduces downtime and protects your system from leaks and failures.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures leak-proof connections to safeguard your chemical feed pump system\u003c\/li\u003e\n  \u003cli\u003eDurable construction enhances long-term reliability under typical water treatment conditions\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard 1\/4” Stenner pump fittings for easy integration\u003c\/li\u003e\n  \u003cli\u003ePack of 10 nuts provides excellent value for maintenance and replacements\u003c\/li\u003e\n  \u003cli\u003eReduces risk of chemical exposure by maintaining secure seals\u003c\/li\u003e\n  \u003cli\u003eLightweight design simplifies installation without compromising strength\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe Stenner connection nut acts as a critical fastening component that secures tubing or fittings onto your chemical feed pump. By threading tightly onto the pump’s 1\/4” port, it forms a stable seal that prevents leaks and chemical drips, which are common issues in chemical feed pump systems.\u003c\/p\u003e\n\u003cp\u003eThis nut works in tandem with compatible tubing and connectors to maintain a continuous, controlled flow of chemicals through your water softening or treatment setup, ensuring precision dosing and system safety.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the STUCAK100 connection nut, you’ll notice an immediate improvement in connection stability and leak prevention. In the first days and weeks, the nuts maintain a firm grip even under pressure changes typical in chemical feed pumps.\u003c\/p\u003e\n\u003cp\u003eOver time, these nuts provide consistent performance with minimal maintenance required. Their durable design withstands routine system vibrations and chemical exposure, helping to extend the lifespan of your water treatment components.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTen Stenner 1\/4” connection nuts – Each engineered for a secure, leak-resistant fit\u003c\/li\u003e\n  \u003cli\u003ePrecision threading – Ensures smooth installation and reliable sealing\u003c\/li\u003e\n  \u003cli\u003eChemical-resistant material – Protects against corrosion and degradation in chemical feed environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off your chemical feed pump and relieve system pressure before installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the old or damaged connection nut from the pump fitting.\u003c\/li\u003e\n  \u003cli\u003eAlign the new STUCAK100 connection nut with the 1\/4” port on your Stenner pump.\u003c\/li\u003e\n  \u003cli\u003eThread the nut onto the fitting by hand, then tighten securely using a wrench—avoid over-tightening.\u003c\/li\u003e\n  \u003cli\u003eReconnect tubing or accessories and ensure all connections are properly seated.\u003c\/li\u003e\n  \u003cli\u003eRestore system pressure and check for leaks around the newly installed connection nut.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt to last with materials resistant to chemicals and wear\u003c\/li\u003e\n  \u003cli\u003eTrusted by water treatment professionals for consistent performance\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically to fit Stenner chemical feed pump systems for hassle-free compatibility\u003c\/li\u003e\n  \u003cli\u003ePack sizing supports both routine maintenance and emergency replacements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this nut compatible with all Stenner chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed for standard 1\/4” Stenner pump fittings; verify your model’s specifications to ensure compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace these connection nuts?\u003c\/strong\u003e\u003cbr\u003eReplace them whenever you notice wear, cracks, or leaks, or as part of routine system maintenance to ensure reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I reuse the nuts after removal?\u003c\/strong\u003e\u003cbr\u003eIt’s best to replace them to maintain a secure and leak-free connection, as threads may wear after repeated use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre these nuts resistant to chemical corrosion?\u003c\/strong\u003e\u003cbr\u003eYes, they are made from materials intended to withstand typical chemicals used in water treatment systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the recommended tightening method?\u003c\/strong\u003e\u003cbr\u003eHand-tighten first, then use a wrench to secure snugly without over-tightening to prevent damage.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this essential Stenner connection nut pack to your cart and keep your chemical feed pump operating smoothly with secure, leak-proof connections.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820150837,"sku":"780851339692","price":41.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stucak100.jpg?v=1764174778"},{"product_id":"stmagcsgr-stenner-grease-5-5-oz-tube-magre55","title":"STMAGCSGR, Stenner Grease 5.5 oz.Tube, MAGRE55","description":"\u003cp\u003e\u003cstrong\u003eSTMAGCSGR Stenner Grease 5.5 oz Tube – Ensure Smooth Operation of Chemical Feed Pumps\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen maintaining your water treatment system, reliable lubrication is key to preventing downtime and costly repairs. The STMAGCSGR Stenner Grease 5.5 oz Tube offers a specialized solution designed for chemical feed pumps and accessories. This high-quality grease provides consistent performance, protecting pump components from wear and corrosion in demanding water softener and chemical dosing environments.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eProtects chemical feed pump parts from friction and wear, extending equipment lifespan\u003c\/li\u003e\n  \u003cli\u003eResists chemical degradation, ensuring consistent lubrication in harsh water treatment conditions\u003c\/li\u003e\n  \u003cli\u003eMaintains pump efficiency by reducing mechanical resistance and preventing overheating\u003c\/li\u003e\n  \u003cli\u003eEasy-to-apply tube format allows precise application without mess or waste\u003c\/li\u003e\n  \u003cli\u003eHelps prevent downtime by minimizing maintenance frequency and unexpected failures\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of water softener and chemical dosing pump models\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThis specialized grease is formulated to lubricate moving parts within chemical feed pumps and related accessories. By creating a protective barrier between metal surfaces, it reduces friction and prevents metal-to-metal contact that can cause wear or corrosion. In water softener systems, where pumps handle various chemical additives, the grease’s chemical resistance ensures it remains effective without breaking down.\u003c\/p\u003e\n\u003cp\u003eApplied during routine maintenance, the grease keeps pump components running smoothly, supporting consistent chemical feed rates and system reliability.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eImmediately after application, you’ll notice smoother pump operation with reduced noise and resistance. Within the first few days and weeks, the grease continues to protect internal parts from wear, helping maintain optimal pump performance. Over the longer term, regular use of this grease reduces the need for frequent maintenance and extends the service life of your chemical feed pump components.\u003c\/p\u003e\n\u003cp\u003eBy investing in proper lubrication with the STMAGCSGR Stenner Grease, you help ensure your water treatment system operates efficiently and reliably over time.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePremium lubricant base – provides long-lasting friction reduction and wear protection\u003c\/li\u003e\n  \u003cli\u003eChemically resistant additives – maintain grease stability against water softener chemicals\u003c\/li\u003e\n  \u003cli\u003eThickening agents – ensure the grease stays in place on pump parts even under pressure\u003c\/li\u003e\n  \u003cli\u003e5.5 oz tube packaging – designed for easy, precise application in tight pump assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and disconnect power to ensure safety.\u003c\/li\u003e\n  \u003cli\u003eRemove any existing grease or debris from the pump’s lubrication points using a clean cloth.\u003c\/li\u003e\n  \u003cli\u003eOpen the STMAGCSGR Stenner Grease tube and apply a moderate amount directly to moving parts or bearings as specified by your pump’s manufacturer.\u003c\/li\u003e\n  \u003cli\u003eRotate the pump shaft by hand to evenly distribute the grease across contact surfaces.\u003c\/li\u003e\n  \u003cli\u003eReassemble any covers or housings and restore power to the pump.\u003c\/li\u003e\n  \u003cli\u003eRun the pump briefly to confirm smooth operation and proper lubrication.\u003c\/li\u003e\n  \u003cli\u003eRepeat lubrication as part of routine maintenance every few months or according to system usage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to meet the specific lubrication demands of water softener and chemical feed pump systems\u003c\/li\u003e\n  \u003cli\u003eTrusted by professionals for durability and chemical resistance in challenging water treatment environments\u003c\/li\u003e\n  \u003cli\u003eCompact 5.5 oz tube fits easily into maintenance kits and storage areas without added bulk\u003c\/li\u003e\n  \u003cli\u003eProduced by Water Softener Plus, a vendor known for quality parts and accessories tailored to water treatment needs\u003c\/li\u003e\n  \u003cli\u003eHelps maintain the performance and longevity of your system’s chemical feed pumps and accessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this grease compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eSTMAGCSGR Stenner Grease is designed for compatibility with most chemical feed pumps and accessories, but always check your pump manufacturer’s guidelines before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I apply this grease?\u003c\/strong\u003e\u003cbr\u003eRegular lubrication every 3 to 6 months is recommended depending on pump usage and environmental conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this grease be used in outdoor or humid environments?\u003c\/strong\u003e\u003cbr\u003eYes, it offers excellent resistance to moisture and chemical exposure common in water treatment setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any special storage requirements?\u003c\/strong\u003e\u003cbr\u003eStore the grease tube in a cool, dry place away from direct sunlight to maintain product integrity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product safe to handle?\u003c\/strong\u003e\u003cbr\u003eUse standard gloves when applying grease and avoid prolonged skin contact. Follow basic safety precautions outlined in your system’s maintenance manual.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STMAGCSGR Stenner Grease 5.5 oz Tube to your cart and keep your chemical feed pumps running smoothly for years to come.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820249141,"sku":"780851339705","price":114.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stmagcsgr.jpg?v=1764174784"},{"product_id":"stucak200-stenner-ferrule-1-4-10-pk-ucak200","title":"STUCAK200, Stenner Ferrule, 1\/4 (10 Pk), UCAK200","description":"\u003cp\u003e\u003cstrong\u003eStenner Ferrule 1\/4\" – Ensure Precise Chemical Feed Pump Connections for Reliable Water Treatment\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen managing chemical feed pumps and water treatment systems, secure and leak-free connections are critical. The STUCAK200 Stenner Ferrule 1\/4\" (10 Pack) offers a dependable solution designed specifically for chemical feed pump accessories. Its robust construction and precise fit help maintain system integrity, reducing downtime and improving overall efficiency in your water treatment setup.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures tight, leak-proof connections to prevent chemical spills and system inefficiencies.\u003c\/li\u003e\n  \u003cli\u003eDurable materials resist corrosion and wear, extending the life of your feed pump components.\u003c\/li\u003e\n  \u003cli\u003eStandard 1\/4\" size fits most Stenner chemical feed pumps and compatible accessories.\u003c\/li\u003e\n  \u003cli\u003ePack of 10 provides ample supply for multiple installations or maintenance cycles.\u003c\/li\u003e\n  \u003cli\u003eLightweight and compact design simplifies installation without adding bulk or weight.\u003c\/li\u003e\n  \u003cli\u003eHelps maintain consistent chemical dosing for effective water softening and treatment processes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe Stenner Ferrule functions as a key connector within chemical feed pump systems, specifically designed to secure tubing and fittings. When installed, it compresses around the tubing, creating a tight seal that prevents leaks and maintains consistent chemical flow. This precision fitting is essential to ensure that the chemical feed pump delivers accurate dosing without pressure loss or contamination.\u003c\/p\u003e\n\n\u003cp\u003eBy using the correct ferrule size and material, the system safeguards against common issues such as chemical exposure damage and mechanical wear, helping your water treatment components perform reliably over time.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you will immediately notice a secure and stable connection that reduces the risk of leaks or disconnections during operation. In the first few days and weeks, the ferrules will settle into place, maintaining constant pressure and chemical flow without requiring adjustment.\u003c\/p\u003e\n\n\u003cp\u003eOver the longer term, these ferrules provide durable performance with minimal maintenance, enabling you to focus on other aspects of your water treatment system without frequent concerns about component failure or replacement.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStenner 1\/4\" Ferrules (10 Pack)\u003c\/strong\u003e – Precision-engineered connectors made from corrosion-resistant materials ensuring a tight seal and long-lasting durability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging\u003c\/strong\u003e – Organized for easy handling and storage, preventing damage and loss during transport or maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before installation.\u003c\/li\u003e\n  \u003cli\u003eCut the tubing squarely to ensure a clean, straight edge for the ferrule connection.\u003c\/li\u003e\n  \u003cli\u003eSlide the ferrule onto the tubing, positioning it correctly according to the pump manufacturer’s instructions.\u003c\/li\u003e\n  \u003cli\u003eInsert the tubing with ferrule into the pump fitting or accessory port firmly.\u003c\/li\u003e\n  \u003cli\u003eTighten the fitting to compress the ferrule, creating a secure, leak-proof seal.\u003c\/li\u003e\n  \u003cli\u003eTurn the system back on and check for any leaks or irregularities in chemical flow.\u003c\/li\u003e\n  \u003cli\u003eRepeat as necessary for all tubing connections requiring ferrules.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to high-quality standards for chemical feed pump compatibility and durability.\u003c\/li\u003e\n  \u003cli\u003eProduced by Water Softener Plus, a trusted vendor specializing in water treatment components.\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for chemical feed pumps and accessories, ensuring optimal fit and performance.\u003c\/li\u003e\n  \u003cli\u003eOffers a cost-effective solution with a convenient 10-pack quantity for ongoing maintenance needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this ferrule compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed for Stenner chemical feed pumps and many compatible systems, especially those requiring a 1\/4\" ferrule size.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the ferrules?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on system usage and chemical exposure, but regular inspection during maintenance cycles is recommended to ensure integrity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I install the ferrule without professional help?\u003c\/strong\u003e\u003cbr\u003eYes, installation is straightforward with basic tools, but always follow safety precautions and manufacturer guidelines.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eAre these ferrules resistant to chemical corrosion?\u003c\/strong\u003e\u003cbr\u003eYes, they are made from materials selected to resist common chemicals used in water treatment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should I do if I notice leaks after installation?\u003c\/strong\u003e\u003cbr\u003eCheck that the ferrule is properly seated and fittings are tightened to the correct specification before operation.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820281909,"sku":"780851339691","price":27.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stucak200.jpg?v=1764174786"},{"product_id":"stcp5latch-stenner-ltch-kit-for-pmp-hd-pk-of-2-qp401-2","title":"STCP5LATCH, Stenner Ltch Kit for Pmp Hd, Pk.of 2, QP401-2","description":"\u003cp\u003e\u003cstrong\u003eReliable Stenner Latch Kit for Chemical Feed Pumps – Secure Your Water Treatment System with Ease\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen maintaining your chemical feed pumps, having dependable accessories like the STCP5LATCH Stenner Latch Kit is essential. Designed specifically for heavy-duty pump applications, this latch kit offers a secure and efficient solution for chemical feed pumps part and accessories needs. Its robust construction ensures your water treatment system stays operational and leak-free, reducing downtime and improving overall system reliability.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnhances pump security by firmly locking pump components in place\u003c\/li\u003e\n  \u003cli\u003eDurable design withstands harsh chemical environments and frequent use\u003c\/li\u003e\n  \u003cli\u003eEasy to install, saving time during maintenance or replacement\u003c\/li\u003e\n  \u003cli\u003ePackaged as a set of two for convenient dual replacements or backups\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner heavy-duty pumps, ensuring a perfect fit\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STCP5LATCH latch kit functions as a critical holding mechanism within the chemical feed pump assembly. It securely fastens the pump head, preventing accidental dislodging or leaks during operation. By maintaining a tight seal and firm connection, the latch kit helps the pump deliver precise chemical dosing without interruptions.\u003c\/p\u003e\n\u003cp\u003eInstalled directly onto the pump housing, the latch kit's resilient materials resist chemical corrosion and mechanical wear, ensuring long-lasting performance even in demanding water treatment environments.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you’ll immediately notice a more secure pump head connection, reducing any concerns about leaks or loose fittings. In the first days and weeks, the latch kit will maintain consistent pressure and locking strength, contributing to smooth pump operation.\u003c\/p\u003e\n\u003cp\u003eOver time, the durable design requires minimal maintenance, providing reliable service as part of your regular chemical feed pump upkeep. Occasional inspection is recommended to ensure continued integrity, especially in heavy-use systems.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo Stenner Latch Components – crafted for dependable locking and quick release\u003c\/li\u003e\n  \u003cli\u003eHeavy-Duty Materials – resistant to chemical corrosion and mechanical stress\u003c\/li\u003e\n  \u003cli\u003ePrecision Fit Elements – designed specifically for Stenner heavy-duty pump models\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve any pressure before starting installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing latch components carefully from the pump head.\u003c\/li\u003e\n  \u003cli\u003ePosition the new latch kit parts in place, aligning with the designated mounting points on the pump.\u003c\/li\u003e\n  \u003cli\u003eSecure the latch firmly, ensuring it locks the pump head without excessive force.\u003c\/li\u003e\n  \u003cli\u003eTest the latch by gently attempting to move the pump head to confirm a tight fit.\u003c\/li\u003e\n  \u003cli\u003eRestart pump operation and monitor for proper function and leak prevention.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt with high-quality materials to endure chemical exposure and heavy use\u003c\/li\u003e\n  \u003cli\u003eManufactured by Water Softener Plus, a trusted vendor in water treatment components\u003c\/li\u003e\n  \u003cli\u003eSpecifically engineered for Stenner heavy-duty pumps, ensuring compatibility and performance\u003c\/li\u003e\n  \u003cli\u003eOffers a cost-effective solution by including two latches in one convenient package\u003c\/li\u003e\n  \u003cli\u003eImproves overall system uptime by preventing common latch-related failures\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this latch kit compatible with all Stenner pumps?\u003c\/strong\u003e\u003cbr\u003eThe STCP5LATCH is designed specifically for Stenner heavy-duty pump models; please verify your pump model before purchasing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should the latch kit be inspected or replaced?\u003c\/strong\u003e\u003cbr\u003eRegular inspection during routine maintenance is recommended. Replacement depends on wear but typically happens when signs of corrosion or looseness appear.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I install this latch kit myself?\u003c\/strong\u003e\u003cbr\u003eYes, the latch kit is user-friendly and can be installed by following basic safety precautions and the provided steps.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWill the latch kit resist chemical damage?\u003c\/strong\u003e\u003cbr\u003eYes, it is made from materials designed to withstand harsh chemicals commonly used in water treatment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat should I do if the latch doesn’t fit correctly?\u003c\/strong\u003e\u003cbr\u003eDouble-check compatibility with your pump model and ensure proper alignment during installation. Contact support if issues persist.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820347445,"sku":"780851339709","price":36.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stcp5latch.jpg?v=1764174789"},{"product_id":"stmcak300-5-stenner-1-4-pvc-inj-ftg-5-pk-mcak300","title":"STMCAK300-5, Stenner 1\/4 PVC Inj Ftg (5-Pk), MCAK300","description":"\u003cp\u003e\u003cstrong\u003eDurable Stenner 1\/4 PVC Injection Fittings for Reliable Chemical Feed Pump Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDesigned specifically for chemical feed pumps, the STMCAK300-5 Stenner 1\/4 PVC Injection Fittings provide a robust and secure connection to optimize your water treatment system. Engineered to resist corrosion and chemical wear, these fittings ensure efficient chemical delivery and reduce downtime. If you’re looking for dependable chemical feed pump parts and accessories that enhance system integrity, this 5-pack is an essential upgrade.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures leak-free chemical injection for safer, cleaner water treatment processes\u003c\/li\u003e\n  \u003cli\u003eResists corrosion and chemical damage, extending the life of your feed pump system\u003c\/li\u003e\n  \u003cli\u003eEasy installation with standard 1\/4 inch PVC sizing, compatible with most feed pumps\u003c\/li\u003e\n  \u003cli\u003eBulk 5-pack provides cost-effective maintenance and replacement options\u003c\/li\u003e\n  \u003cli\u003eLightweight design reduces strain on piping and pump components\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of chemical feed pump accessories for versatile use\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STMCAK300-5 fittings connect directly to your chemical feed pump’s injection point, allowing precise and controlled delivery of treatment chemicals into your water system. Made from durable PVC, they withstand harsh chemicals and pressure fluctuations common in water softener and treatment setups.\u003c\/p\u003e\n\u003cp\u003eBy securely linking tubing or piping, these fittings prevent leaks and maintain consistent chemical flow. Their injection fitting design ensures a tight seal and consistent dosing, crucial for maintaining water quality and system performance.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing these injection fittings, you’ll immediately notice a tighter, more reliable connection in your chemical feed system. This reduces the risk of leaks and chemical loss, supporting safer operation. Within the first few days, expect smoother chemical flow and fewer interruptions.\u003c\/p\u003e\n\u003cp\u003eOver weeks and months, the corrosion-resistant PVC material maintains integrity, minimizing maintenance needs and replacement frequency. This translates to long-term reliability and consistent chemical dosing without the worry of fitting degradation or failure.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e1\/4 inch PVC Injection Fittings – crafted for chemical resistance and secure connections in feed pump systems\u003c\/li\u003e\n  \u003cli\u003ePrecision-molded coupling ends – designed for tight, leak-proof seals with tubing or piping\u003c\/li\u003e\n  \u003cli\u003eDurable PVC housing – lightweight yet strong to withstand chemical exposure and system pressure\u003c\/li\u003e\n  \u003cli\u003ePack of 5 fittings – providing multiple replacements or installations, ideal for ongoing system maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve any system pressure before installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing injection fitting or prepare the tubing end by cutting cleanly and squarely.\u003c\/li\u003e\n  \u003cli\u003eInsert the tubing firmly into the 1\/4 inch PVC fitting until fully seated.\u003c\/li\u003e\n  \u003cli\u003eSecure the fitting by tightening any locking nuts or clamps as applicable to your system.\u003c\/li\u003e\n  \u003cli\u003eTurn the chemical feed pump back on and check for leaks at the fitting connection.\u003c\/li\u003e\n  \u003cli\u003eMonitor initial operation to ensure consistent chemical flow and adjust if necessary.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured by Water Softener Plus, known for reliable water treatment components\u003c\/li\u003e\n  \u003cli\u003eHigh-quality PVC material offers excellent chemical resistance and durability\u003c\/li\u003e\n  \u003cli\u003eDesigned to integrate seamlessly with most chemical feed pumps and accessories\u003c\/li\u003e\n  \u003cli\u003eProvides a cost-effective solution for maintaining system efficiency and safety\u003c\/li\u003e\n  \u003cli\u003eLightweight design reduces stress on pump lines, promoting longer system life\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this fitting compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most pumps using standard 1\/4 inch PVC injection fittings but always verify your system specifications before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should these fittings be replaced?\u003c\/strong\u003e\u003cbr\u003eReplacement depends on chemical exposure and usage but typically every 1–2 years or when signs of wear or leaks appear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install these fittings myself?\u003c\/strong\u003e\u003cbr\u003eYes, with basic plumbing knowledge and by following safety precautions, installation is straightforward.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre these fittings safe for all water treatment chemicals?\u003c\/strong\u003e\u003cbr\u003eThey are designed for compatibility with common water treatment chemicals but avoid highly aggressive solvents not suited for PVC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat maintenance is required for these fittings?\u003c\/strong\u003e\u003cbr\u003eRegularly inspect for leaks or cracks and clean any buildup to maintain optimal performance.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this STMCAK300-5 1\/4 PVC Injection Fitting 5-pack to your cart and keep your water flowing clean and consistent with trusted chemical feed pump components.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820412981,"sku":"780851339703","price":64.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stmcak300-5.jpg?v=1764174794"},{"product_id":"stmp6no80-stenner-phenolic-gear-series-85-170-mp6no80","title":"STMP6NO80, Stenner Phenolic Gear Series 85 \u0026 170, MP6NO80","description":"\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pumps Part for Efficient Water Treatment Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STMP6NO80, Stenner Phenolic Gear Series 85 \u0026amp; 170, MP6NO80 offers a durable and precise replacement part designed to enhance your chemical feed pump system. Specifically engineered for water treatment applications, this phenolic gear component ensures consistent operation and reduces downtime. If you’re seeking a dependable chemical feed pumps part and accessory that integrates seamlessly with your existing setup, this model delivers efficiency and longevity.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures smooth and reliable chemical dosing to protect your water system\u003c\/li\u003e\n  \u003cli\u003eResistant to corrosion and chemical wear for extended service life\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner Series 85 and 170 pumps for easy integration\u003c\/li\u003e\n  \u003cli\u003eMinimizes pump maintenance by reducing mechanical wear\u003c\/li\u003e\n  \u003cli\u003eLightweight phenolic construction reduces overall system strain\u003c\/li\u003e\n  \u003cli\u003eImproves accuracy in chemical feed rates for optimized water treatment\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThis phenolic gear is a critical internal component within the chemical feed pump, responsible for transferring mechanical power smoothly to move chemicals accurately through your water treatment system. When installed inside the Stenner Series 85 or 170 pump, it meshes precisely with other gears to convert motor rotations into consistent chemical dosing flow.\u003c\/p\u003e\n\u003cp\u003eIts phenolic resin construction allows it to withstand exposure to harsh chemicals and moisture, ensuring that the gear maintains performance without degrading. This reliability supports consistent chemical feed rates, which are essential for effective water softening and treatment processes.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you will notice that your chemical feed pump runs more quietly and efficiently due to the precise fit and smooth operation of the phenolic gear. In the first few days, expect improved dosing consistency, which translates into better treatment results. Over the longer term, this component’s durable build minimizes the need for frequent replacements, reducing both downtime and maintenance costs.\u003c\/p\u003e\n\u003cp\u003eRegular system checks will confirm continued performance, but the robust design is intended to withstand typical operational stresses, supporting your water treatment system’s reliability for months or even years.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003ePhenolic Gear – Provides chemical resistance and mechanical strength for accurate chemical dosing\u003c\/li\u003e\n  \u003cli\u003ePrecision-Machined Teeth – Ensures smooth engagement with mating gears to reduce wear\u003c\/li\u003e\n  \u003cli\u003eCompact Design – Fits seamlessly into Stenner Series 85 \u0026amp; 170 pumps without adding extra weight\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off power and chemical feed supply to the pump before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eDisassemble the pump housing carefully to access the internal gear assembly.\u003c\/li\u003e\n  \u003cli\u003eRemove the worn or damaged phenolic gear and clean the gear chamber thoroughly.\u003c\/li\u003e\n  \u003cli\u003eInstall the new STMP6NO80 phenolic gear, ensuring proper alignment with adjacent gears.\u003c\/li\u003e\n  \u003cli\u003eReassemble the pump housing securely and restore chemical feed connections.\u003c\/li\u003e\n  \u003cli\u003eTurn on the power and test the pump to confirm smooth, consistent chemical dosing.\u003c\/li\u003e\n  \u003cli\u003eMonitor the system during initial operation for any unusual noises or leaks.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-quality phenolic materials ensure long-term durability in harsh chemical environments.\u003c\/li\u003e\n  \u003cli\u003eDesigned by Water Softener Plus, a trusted vendor specializing in water treatment components.\u003c\/li\u003e\n  \u003cli\u003ePerfectly engineered for compatibility with popular Stenner pump models, simplifying upgrades and repairs.\u003c\/li\u003e\n  \u003cli\u003eLightweight yet strong construction reduces stress on pump motors and extends overall system life.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this phenolic gear compatible with all Stenner pumps?\u003c\/strong\u003e\u003cbr\u003eThis gear is specifically designed for Stenner Series 85 and 170 models; compatibility with other models is not guaranteed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the phenolic gear?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency varies with usage but typically is recommended when signs of wear or reduced dosing accuracy appear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this part myself?\u003c\/strong\u003e\u003cbr\u003eYes, with basic mechanical skills and by following proper safety procedures, installation is straightforward.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any special maintenance requirements?\u003c\/strong\u003e\u003cbr\u003eRegular inspection for wear and cleaning of the pump housing will help maintain optimal performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the phenolic gear safe to use with all common chemical feed solutions?\u003c\/strong\u003e\u003cbr\u003eIt is designed to resist most standard water treatment chemicals, but check compatibility with highly abrasive or unusual chemicals before use.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820806197,"sku":"780851339697","price":45.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stmp6n080.jpg?v=1764174801"},{"product_id":"stfc5080d-stenner-feed-rate-ctrl-45-85-ser-w-shft-fc5040d","title":"STFC5080D, Stenner Feed Rate Ctrl 45\/85 Ser, W\/Shft, FC5040D","description":"\u003cp\u003e\u003cstrong\u003eStenner Feed Rate Control for Chemical Feed Pumps – Precision and Reliability in Water Treatment\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen managing chemical feed pumps, precision and control are essential to maintaining effective water treatment systems. The STFC5080D Stenner Feed Rate Control offers dependable, accurate feed rate adjustment specifically designed for the 45\/85 series pumps with shaft coupling. This high-quality feed rate controller ensures consistent chemical dosing, reducing system downtime and improving overall operational safety.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eProvides precise feed rate adjustment to optimize chemical dosing and system performance\u003c\/li\u003e\n  \u003cli\u003eEnhances pump reliability by reducing overfeed and chemical waste\u003c\/li\u003e\n  \u003cli\u003eEasy integration with Stenner 45\/85 series chemical feed pumps for seamless operation\u003c\/li\u003e\n  \u003cli\u003eDurable build designed to withstand harsh water treatment environments\u003c\/li\u003e\n  \u003cli\u003eImproves safety by offering controlled chemical feed rates, minimizing risk of system damage\u003c\/li\u003e\n  \u003cli\u003eReduces maintenance frequency through stable, consistent operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STFC5080D works by precisely controlling the feed rate of chemicals injected by Stenner 45\/85 series pumps. It attaches directly to the pump shaft, allowing for mechanical adjustment of the chemical feed speed. This ensures chemicals are introduced at a steady, controlled rate, which is critical in water softener systems, chemical feed applications, and water treatment setups.\u003c\/p\u003e\n\u003cp\u003eBy regulating the feed rate mechanically, the unit avoids fluctuations or spikes in chemical dosing, helping maintain consistent water quality and protecting downstream equipment from chemical imbalances or damage.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eUpon installation, you will notice immediate improvement in the accuracy and consistency of chemical feed rates. The adjustment process is straightforward, allowing you to fine-tune dosing to match your system’s specific requirements. During the first few days and weeks, the controller stabilizes pump performance, reducing chemical waste and optimizing system efficiency.\u003c\/p\u003e\n\u003cp\u003eOver the longer term, expect reduced maintenance needs due to fewer pump strain episodes and enhanced component longevity. The robust construction supports ongoing reliable operation in demanding water treatment environments.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFeed Rate Control Mechanism\u003c\/strong\u003e – Provides precise mechanical adjustment of chemical feed speed\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable Shaft Coupling\u003c\/strong\u003e – Ensures secure connection to Stenner 45\/85 series pumps for accurate control\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Housing\u003c\/strong\u003e – Protects internal components from chemical exposure and environmental wear\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCalibration Scale\u003c\/strong\u003e – Allows easy and repeatable feed rate setting for consistent dosing\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before installation.\u003c\/li\u003e\n  \u003cli\u003eAttach the STFC5080D feed rate control unit securely to the pump shaft according to the manufacturer’s instructions.\u003c\/li\u003e\n  \u003cli\u003eUse the calibration scale to set the desired chemical feed rate based on your system requirements.\u003c\/li\u003e\n  \u003cli\u003eRestart the pump and monitor the chemical feed rate to ensure it matches the set parameters.\u003c\/li\u003e\n  \u003cli\u003eAdjust the feed rate as needed during routine system checks to maintain optimal performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered for durability and consistent performance in chemical feed pump systems\u003c\/li\u003e\n  \u003cli\u003eProduced by Water Softener Plus, a trusted vendor specializing in water treatment components\u003c\/li\u003e\n  \u003cli\u003eSpecifically designed for compatibility with Stenner 45\/85 series pumps, ensuring seamless integration\u003c\/li\u003e\n  \u003cli\u003eSupports efficient water treatment by enabling precise chemical dosing control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this feed rate control compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eThe STFC5080D is specifically designed for Stenner 45\/85 series pumps with shaft coupling and may not fit other models.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should I calibrate the feed rate?\u003c\/strong\u003e\u003cbr\u003eRegular calibration is recommended during routine maintenance, typically every few months, to maintain accuracy.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this controller handle harsh chemical environments?\u003c\/strong\u003e\u003cbr\u003eYes, it features a durable housing designed to withstand exposure to common water treatment chemicals.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs professional installation required?\u003c\/strong\u003e\u003cbr\u003eInstallation can be performed by a knowledgeable technician or trained operator following safety guidelines.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat maintenance does this product need?\u003c\/strong\u003e\u003cbr\u003ePeriodic inspection and calibration are advised to ensure ongoing precise feed rate control.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819820871733,"sku":"780851339708","price":512.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stfc5080d.jpg?v=1764174805"},{"product_id":"stucak300-stenner-pvc-injection-fitting-1-4-ucak300","title":"STUCAK300, Stenner PVC Injection Fitting, 1\/4, UCAK300","description":"\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Injection with STUCAK300 Stenner PVC Injection Fitting for Precise Water Treatment\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STUCAK300 Stenner PVC Injection Fitting is engineered to provide a dependable and efficient solution for chemical feed pumps in water treatment systems. Designed specifically for 1\/4-inch tubing connections, this injection fitting ensures secure chemical injection while minimizing leaks and system wear. Ideal for those seeking a durable chemical feed pumps part and accessory, it offers enhanced system reliability and ease of maintenance.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures precise chemical injection for consistent water treatment performance\u003c\/li\u003e\n  \u003cli\u003eProtects your system from leaks with a secure, tight PVC fitting design\u003c\/li\u003e\n  \u003cli\u003eResists corrosion and chemical damage for long-lasting durability\u003c\/li\u003e\n  \u003cli\u003eCompatible with Stenner pumps and other standard chemical feed systems\u003c\/li\u003e\n  \u003cli\u003eLightweight construction reduces strain on pump components and tubing\u003c\/li\u003e\n  \u003cli\u003eSimplifies installation and maintenance for minimal downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STUCAK300 injection fitting connects directly to your chemical feed pump tubing, allowing precise dosing of treatment chemicals into your water system. Its robust PVC construction withstands chemical exposure while maintaining a tight seal, preventing leaks or backflow. The fitting’s design directs chemical flow efficiently into the injection point, supporting consistent system operation and optimal water quality.\u003c\/p\u003e\n\u003cp\u003eBy integrating seamlessly with your existing pump and system setup, this fitting acts as the critical link between the chemical feed pump and the water supply, ensuring that the correct chemical volumes are injected safely and reliably.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eImmediately after installation, you’ll notice a secure and leak-free connection that enhances the overall integrity of your chemical feed system. Within the first few days, the fitting will maintain consistent chemical dosing without requiring adjustments. Over time, its corrosion-resistant PVC body provides lasting performance, reducing the need for frequent replacements or repairs.\u003c\/p\u003e\n\u003cp\u003eRoutine inspections are straightforward, and the fitting’s durable design minimizes maintenance, helping keep your water treatment system running smoothly and efficiently.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePVC Injection Fitting Body\u003c\/strong\u003e – Provides chemical resistance and structural durability for long-term use\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1\/4-Inch Tubing Connection\u003c\/strong\u003e – Ensures a snug, leak-resistant fit with standard chemical feed pump tubing\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSealing Components\u003c\/strong\u003e – Maintain a tight seal to prevent leaks and chemical backflow\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSturdy Mounting Design\u003c\/strong\u003e – Offers easy integration into existing water treatment setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before installation.\u003c\/li\u003e\n  \u003cli\u003eConnect the 1\/4-inch tubing from your chemical feed pump securely into the STUCAK300 fitting.\u003c\/li\u003e\n  \u003cli\u003eEnsure all connections are tight and properly seated to avoid leaks.\u003c\/li\u003e\n  \u003cli\u003eMount the fitting in the designated injection point according to your system’s requirements.\u003c\/li\u003e\n  \u003cli\u003eTurn the pump back on and check for proper chemical flow and absence of leaks.\u003c\/li\u003e\n  \u003cli\u003ePerform routine inspections to verify ongoing secure connections and fitting integrity.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured from high-quality PVC for superior chemical resistance and durability\u003c\/li\u003e\n  \u003cli\u003eTrusted brand compatibility ensures seamless integration with Stenner and similar chemical feed pumps\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for water treatment applications, optimizing system performance\u003c\/li\u003e\n  \u003cli\u003eLightweight yet strong, reducing wear and tear on connected components\u003c\/li\u003e\n  \u003cli\u003eEasy to install and maintain, minimizing system downtime\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the STUCAK300 compatible with all chemical feed pumps?\u003c\/strong\u003e\u003cbr\u003eIt is designed primarily for Stenner pumps and other systems using 1\/4-inch tubing but may fit other similar chemical feed pumps—always verify your system specifications before installation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should I inspect or replace the injection fitting?\u003c\/strong\u003e\u003cbr\u003eRegular inspections are recommended during routine system maintenance; replacement is typically only necessary if signs of wear or damage appear.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan this fitting handle all types of treatment chemicals?\u003c\/strong\u003e\u003cbr\u003eThe PVC construction resists most common water treatment chemicals; however, check chemical compatibility if using highly aggressive substances.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eThis fitting performs well within typical water treatment system temperature ranges but avoid exposure to extreme heat to preserve material integrity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs professional installation recommended?\u003c\/strong\u003e\u003cbr\u003eWhile installation is straightforward, following safety and system guidelines is important; consult a professional if unsure.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819821363253,"sku":"780851339690","price":33.21,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stucak300.jpg?v=1764174813"},{"product_id":"stmcak200-24-stenner-1-4-ferrules-24-pk-mcak200","title":"STMCAK200-24, Stenner 1\/4 Ferrules (24-Pk), MCAK200","description":"\u003cp\u003e\u003cstrong\u003eSTMCAK200-24 Stenner 1\/4 Ferrules: Precision Chemical Feed Pump Accessories for Reliable Water Treatment\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen maintaining your water treatment system, every component matters—especially parts like chemical feed pump ferrules that ensure a secure, leak-free connection. The STMCAK200-24 Stenner 1\/4 Ferrules (24-Pk) offer a dependable and efficient solution for chemical feed pumps and accessories, designed to keep your system running smoothly. These ferrules are engineered to provide a consistent seal, reducing downtime and improving the overall safety of your water softener or treatment setup.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures leak-proof connections, protecting your system from chemical leaks and damage\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard 1\/4-inch tubing for versatile use in chemical feed pumps\u003c\/li\u003e\n  \u003cli\u003eDurable construction withstands chemical exposure and pressure fluctuations\u003c\/li\u003e\n  \u003cli\u003eEasy to install, reducing maintenance time and labor costs\u003c\/li\u003e\n  \u003cli\u003ePack of 24 provides ample supply for routine maintenance and quick replacements\u003c\/li\u003e\n  \u003cli\u003eHelps maintain consistent chemical dosing, improving water treatment accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STMCAK200-24 ferrules function as compression fittings within chemical feed pump systems. When installed onto 1\/4-inch tubing, they create a tight seal by compressing against the tube and pump housing, preventing leaks and chemical spills. This secure connection is vital for maintaining precise chemical flow rates and protecting sensitive components from exposure.\u003c\/p\u003e\n\u003cp\u003eBy ensuring a stable, leak-free interface between tubing and pump parts, these ferrules play a key role in the overall efficiency of your water softener or chemical feed setup, contributing to system longevity and optimal performance.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the STMCAK200-24 ferrules, you’ll immediately notice a more secure and stable connection in your chemical feed pump system. The tight seal minimizes the risk of leaks, enhancing safety during chemical treatment processes. Within the first few days to weeks, you can expect consistent chemical dosing with fewer interruptions or maintenance issues.\u003c\/p\u003e\n\u003cp\u003eOver the longer term, these ferrules offer reliable durability against chemical corrosion and pressure stresses, helping reduce the frequency of replacements and keeping your water treatment system operating without costly downtime.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e24 Stenner 1\/4-inch ferrules – precision-engineered to fit standard chemical feed pump tubing and provide a secure, leak-proof seal\u003c\/li\u003e\n  \u003cli\u003eHigh-quality materials – designed to resist chemical corrosion and maintain structural integrity under pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the chemical feed pump and relieve system pressure before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eCut the 1\/4-inch tubing to the desired length, ensuring a clean, straight edge.\u003c\/li\u003e\n  \u003cli\u003eSlide a ferrule onto the tubing, positioning it close to the end.\u003c\/li\u003e\n  \u003cli\u003eInsert the tubing with ferrule into the pump fitting or connector.\u003c\/li\u003e\n  \u003cli\u003eTighten the fitting nut firmly to compress the ferrule and create a secure seal.\u003c\/li\u003e\n  \u003cli\u003eTurn the pump back on and inspect the connection for any signs of leaks.\u003c\/li\u003e\n  \u003cli\u003eReplace ferrules as needed during routine maintenance to maintain optimal system performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured by Stenner, a trusted name in chemical feed pump accessories known for quality and reliability\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for 1\/4-inch tubing, ensuring a perfect fit and optimal performance in water softener and chemical feed applications\u003c\/li\u003e\n  \u003cli\u003eRobust materials provide long-lasting durability in demanding water treatment environments\u003c\/li\u003e\n  \u003cli\u003ePackaged in convenient 24-packs, ideal for professional installers and maintenance teams\u003c\/li\u003e\n  \u003cli\u003eBacked by Water Softener Plus, a reliable vendor specializing in water treatment components\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAre these ferrules compatible with all 1\/4-inch tubing?\u003c\/strong\u003e\u003cbr\u003eThey are designed to fit standard 1\/4-inch chemical feed pump tubing; verify your tubing specifications for best compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the ferrules?\u003c\/strong\u003e\u003cbr\u003eInspect them regularly and replace whenever you notice leaks or during routine system maintenance to ensure reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan these ferrules handle exposure to harsh chemicals?\u003c\/strong\u003e\u003cbr\u003eYes, they are made from materials resistant to common chemical feed solutions used in water treatment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs installation difficult for beginners?\u003c\/strong\u003e\u003cbr\u003eNo, the ferrules are easy to install with basic tools by following simple steps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo these ferrules affect the flow rate of my chemical feed pump?\u003c\/strong\u003e\u003cbr\u003eNo, they maintain an unobstructed seal without impacting flow performance.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add the STMCAK200-24 Stenner 1\/4 Ferrules to your cart and keep your water treatment components sealed, secure, and running smoothly.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819821592629,"sku":"780851339704","price":42.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stmcak200-24.jpg?v=1764174818"},{"product_id":"stuccp205-stenner-5-tube-assem-2-pk-uccp205","title":"STUCCP205, Stenner #5 Tube Assem. (2 Pk), UCCP205","description":"\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump Tubing Assembly for Consistent Water Treatment Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to maintaining optimal chemical feed accuracy in your water treatment system, the STUCCP205 Stenner #5 Tube Assembly (2 Pack) offers a dependable and efficient solution. Designed specifically for chemical feed pumps, this tube assembly ensures precise chemical delivery and reduces the risk of leaks or malfunctions. Upgrade your system with a trusted accessory that enhances pump performance and extends equipment life.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures precise chemical dosing for effective water softening and treatment\u003c\/li\u003e\n  \u003cli\u003eDurable construction minimizes wear and reduces the need for frequent replacements\u003c\/li\u003e\n  \u003cli\u003eEasy installation with a two-pack supply to keep your system running smoothly\u003c\/li\u003e\n  \u003cli\u003eCompatible with a broad range of chemical feed pumps, enhancing system flexibility\u003c\/li\u003e\n  \u003cli\u003eHelps prevent leaks and chemical exposure, promoting safer operation\u003c\/li\u003e\n  \u003cli\u003eSupports consistent pump operation, reducing downtime and maintenance costs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe STUCCP205 tube assembly functions as a critical conduit in chemical feed pumps, transferring precise amounts of treatment chemicals from the pump to your water system. Made to fit Stenner #5 pumps, this tubing is engineered to withstand chemical exposure and pressure, ensuring reliable flow without degradation. By maintaining a secure, leak-free connection, it helps your softener or treatment system operate at peak efficiency.\u003c\/p\u003e\n\u003cp\u003eAs chemicals pass through the tubing, the assembly’s durable material resists cracking or swelling, which can otherwise compromise dosing accuracy. This ensures that the right chemical concentration is delivered consistently, protecting your water quality and your equipment.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the STUCCP205 tube assembly, you’ll notice immediate improvements in your chemical feed pump’s reliability and dosing accuracy. Initial use will confirm smooth chemical flow with no leaks or interruptions. Over the first few weeks, the assembly maintains its integrity without swelling or cracking, supporting stable pump performance.\u003c\/p\u003e\n\u003cp\u003eLong-term, this tubing reduces maintenance needs by resisting chemical wear and mechanical stress. With proper installation, it provides a lasting, worry-free replacement that helps you avoid the common issues of degraded tubing, keeping your water treatment system functioning optimally.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eTwo Stenner #5 chemical feed tubes – engineered for high chemical resistance and flexibility\u003c\/li\u003e\n  \u003cli\u003ePrecision-molded ends – ensure a secure, leak-proof connection to your pump and fittings\u003c\/li\u003e\n  \u003cli\u003eDurable polymer material – designed to withstand chemical exposure and pressure variations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off your chemical feed pump and depressurize the system before starting.\u003c\/li\u003e\n  \u003cli\u003eRemove the old tubing assembly carefully, avoiding chemical contact.\u003c\/li\u003e\n  \u003cli\u003eAttach the new STUCCP205 tube assembly by securely fitting the ends onto your pump’s inlet and outlet ports.\u003c\/li\u003e\n  \u003cli\u003eEnsure all connections are tight to prevent leaks.\u003c\/li\u003e\n  \u003cli\u003eTurn the pump back on and monitor for proper chemical flow and any signs of leakage.\u003c\/li\u003e\n  \u003cli\u003eRegularly inspect tubing during routine maintenance to ensure continued performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eConstructed with high-quality materials that withstand harsh chemical environments\u003c\/li\u003e\n  \u003cli\u003eTrusted brand compatibility ensures seamless integration with Stenner chemical feed pumps\u003c\/li\u003e\n  \u003cli\u003eDesigned to enhance water treatment system efficiency and reduce downtime\u003c\/li\u003e\n  \u003cli\u003eTwo-pack provides convenient replacement options for ongoing system maintenance\u003c\/li\u003e\n  \u003cli\u003eBacked by Water Softener Plus’s commitment to reliable water treatment solutions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this tube assembly compatible with all Stenner #5 pumps?\u003c\/strong\u003e\u003cbr\u003eYes, the STUCCP205 is specifically designed to fit Stenner #5 chemical feed pumps for optimal performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I replace the tubing assembly?\u003c\/strong\u003e\u003cbr\u003eReplacement frequency depends on usage and chemical type but typically every 1–2 years or when signs of wear appear.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this tubing assembly myself?\u003c\/strong\u003e\u003cbr\u003eYes, with basic mechanical skills and proper safety precautions, you can install this assembly following the provided steps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any special maintenance requirements?\u003c\/strong\u003e\u003cbr\u003eRegular inspections for leaks or cracks help maintain performance; cleaning is usually not necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this product safe to handle?\u003c\/strong\u003e\u003cbr\u003eAlways wear protective gloves when handling chemical feed components and follow your chemical safety guidelines.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this essential STUCCP205 tube assembly to your cart and keep your water treatment system delivering clean, consistent chemical dosing with confidence.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819821658165,"sku":"780851339686","price":76.44,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stuccp205.jpg?v=1764174821"},{"product_id":"85mhp17-110-stenner-17-gpd-hiprs-pmp-w-1-4-kit-110v-85mjh2a1staa","title":"85MHP17-110, Stenner 17 gpd Hiprs Pmp w\/1\/4 Kit, 110v, 85MJH2A1STAA","description":"\u003c!--wsp-trust-v1--\u003e\u003cdiv class=\"wsp-trust\" style=\"border:1px solid #e5e7eb;border-radius:10px;padding:12px 14px;margin:0 0 14px;background:#f9fafb;font-size:14px;\"\u003e\n\u003cstrong\u003eWhy buy from Water Softener Plus\u003c\/strong\u003e\u003cbr\u003e✔ US-based water treatment specialists   ✔ Ships nationwide \u0026amp; worldwide   ✔ Buy now, pay over time with Shop Pay\u003cbr\u003e✔ Free shipping on US orders over $1,000   ✔ Secure checkout   ✔ Easy returns   ✔ Free expert sizing help — call \u003ca href=\"tel:+18136211985\"\u003e813-621-1985\u003c\/a\u003e   ✔ Free install \u0026amp; service \u003ca href=\"\/zh-hans-as\/manuals\"\u003emanuals\u003c\/a\u003e included\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump for Precise Water Treatment and System Protection\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to managing chemical dosing in water treatment systems, accuracy and dependability are paramount. The 85MHP17-110 Stenner 17 GPD Hiprs Pump with 1\/4 Kit offers a robust solution designed to deliver consistent chemical feed rates, ensuring your water system operates efficiently and safely. Engineered for chemical feed pumps applications, this model combines precision with ease of use to enhance your water softener or treatment setup.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures accurate chemical dosing to maintain water quality and system balance\u003c\/li\u003e\n  \u003cli\u003eProtects your water treatment system by preventing under- or overdosing\u003c\/li\u003e\n  \u003cli\u003eOffers durable construction for long-lasting performance in demanding environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with various chemical solutions, allowing flexible application\u003c\/li\u003e\n  \u003cli\u003eEasy integration with existing water softener and treatment setups\u003c\/li\u003e\n  \u003cli\u003eOperates efficiently on standard 110v power for convenient installation\u003c\/li\u003e\n  \u003cli\u003eIncludes a 1\/4 kit for streamlined setup and precise flow control\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe 85MHP17-110 pump uses a positive displacement mechanism to deliver a steady, measured flow of chemicals into your water treatment system. As water passes through the system, the pump injects precise amounts of conditioning agents or sanitizers, helping to control scale, bacteria, or other contaminants. Its design ensures consistent output regardless of pressure changes, enabling reliable performance throughout its operation.\u003c\/p\u003e\n\u003cp\u003eThis chemical feed pump is ideal for integration with softeners and filtration units, maintaining optimal chemical levels to extend equipment life and improve water quality.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eUpon installation, you will notice immediate improvements in chemical dosing accuracy compared to manual or less precise pumps. Within the first days and weeks, the pump stabilizes system performance by delivering consistent chemical flow, reducing the risk of system imbalance or damage. Over time, its durable build minimizes maintenance needs, though routine inspection of tubing and connections is recommended to ensure continued efficiency.\u003c\/p\u003e\n\u003cp\u003eThe pump’s reliable operation supports your water treatment goals without frequent adjustments, allowing you to focus on other system management tasks confidently.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePositive Displacement Pump Head\u003c\/strong\u003e – Provides precise chemical dosing for consistent system performance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1\/4 Inch Flow Control Kit\u003c\/strong\u003e – Allows fine-tuning of chemical feed rates to match treatment requirements\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Motor Assembly\u003c\/strong\u003e – Ensures reliable operation on standard 110v power supply\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChemically Resistant Tubing\u003c\/strong\u003e – Maintains integrity when handling various treatment chemicals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Hardware\u003c\/strong\u003e – Simplifies installation and secure placement within your water system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eIdentify the appropriate location within your water treatment system for pump installation, ideally near the chemical reservoir.\u003c\/li\u003e\n  \u003cli\u003eSecurely mount the pump using the included hardware to ensure stable operation.\u003c\/li\u003e\n  \u003cli\u003eConnect the chemical feed tubing to the pump head and the injection point in your system, ensuring airtight seals.\u003c\/li\u003e\n  \u003cli\u003eAdjust the 1\/4 inch flow control kit to set the desired chemical feed rate based on system requirements.\u003c\/li\u003e\n  \u003cli\u003ePlug the pump into a 110v power outlet and switch it on to begin chemical dosing.\u003c\/li\u003e\n  \u003cli\u003eMonitor initial operation to confirm proper dosing and make minor adjustments as necessary.\u003c\/li\u003e\n  \u003cli\u003ePerform routine checks on tubing, connections, and pump function to maintain optimal performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt with high-quality materials designed to withstand harsh chemical environments and daily use\u003c\/li\u003e\n  \u003cli\u003eManufactured by a trusted brand known for reliability in water treatment components\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for chemical feed pumps applications, ensuring compatibility and efficiency\u003c\/li\u003e\n  \u003cli\u003eSupports a wide range of water softener and treatment system configurations\u003c\/li\u003e\n  \u003cli\u003eBalances precision and durability to deliver long-term value and peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this pump compatible with all chemical solutions?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most common water treatment chemicals, but always verify chemical compatibility with the pump materials before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I perform maintenance?\u003c\/strong\u003e\u003cbr\u003eRegular inspection every few months is recommended, focusing on tubing integrity and pump operation to prevent leaks or blockages.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this pump with different water softener models?\u003c\/strong\u003e\u003cbr\u003eYes, the pump is designed to integrate easily with various water softener and treatment systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power supply does this pump require?\u003c\/strong\u003e\u003cbr\u003eThe pump operates on a standard 110v electrical supply, common in residential and commercial settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the installation process complicated?\u003c\/strong\u003e\u003cbr\u003eThe included 1\/4 kit and mounting hardware simplify installation, making it manageable for users familiar with basic plumbing and electrical connections.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e\u003c!--wsp-xsell-v1--\u003e\u003cdiv class=\"wsp-xsell\" style=\"margin-top:18px;\"\u003e\n\u003ch2\u003eComplete your system\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/filter-cartridges\"\u003eReplacement filters \u0026amp; cartridges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/resins-filter-media-chemicals\"\u003eMedia \u0026amp; chemicals\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/control-valves-parts\"\u003eParts \u0026amp; accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819822116917,"sku":"780851338240","price":1213.58,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/85mhp-series.jpg?v=1764174827"},{"product_id":"85mhp17-220-stenner-17gpd-hiprs-pmp-w-1-4-kit-220v-85mjh2b1staa","title":"85MHP17-220, Stenner 17gpd Hiprs Pmp w\/1\/4 Kit, 220v, 85MJH2B1STAA","description":"\u003c!--wsp-trust-v1--\u003e\u003cdiv class=\"wsp-trust\" style=\"border:1px solid #e5e7eb;border-radius:10px;padding:12px 14px;margin:0 0 14px;background:#f9fafb;font-size:14px;\"\u003e\n\u003cstrong\u003eWhy buy from Water Softener Plus\u003c\/strong\u003e\u003cbr\u003e✔ US-based water treatment specialists   ✔ Ships nationwide \u0026amp; worldwide   ✔ Buy now, pay over time with Shop Pay\u003cbr\u003e✔ Free shipping on US orders over $1,000   ✔ Secure checkout   ✔ Easy returns   ✔ Free expert sizing help — call \u003ca href=\"tel:+18136211985\"\u003e813-621-1985\u003c\/a\u003e   ✔ Free install \u0026amp; service \u003ca href=\"\/zh-hans-as\/manuals\"\u003emanuals\u003c\/a\u003e included\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump for Precise Water Treatment and Consistent System Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe 85MHP17-220 Stenner 17gpd Hiprs Pump with 1\/4 Kit delivers dependable chemical feed dosing designed to optimize your water treatment system. Unlike generic pumps, this model offers accuracy and durability, ensuring safe and efficient chemical injection in various industrial and residential applications. Its robust construction and precise flow control make it a top choice for chemical feed pumps in demanding setups.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures consistent chemical dosing for improved water quality and system protection\u003c\/li\u003e\n  \u003cli\u003eDesigned for long-term reliability, reducing downtime and maintenance needs\u003c\/li\u003e\n  \u003cli\u003eSupports 220v power systems, allowing integration with standard industrial electrical setups\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight design simplifies installation and handling\u003c\/li\u003e\n  \u003cli\u003eIncludes a 1\/4 kit for easy setup, minimizing installation errors and time\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of chemical feed applications, enhancing versatility\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThis Stenner chemical feed pump operates by precisely metering chemical solutions into your water system at a rate of 17 gallons per day. It uses a high-pressure resistant system (Hiprs) to maintain consistent flow regardless of system pressure fluctuations. By injecting chemicals accurately, it helps maintain optimal water chemistry, preventing scaling, corrosion, or microbial growth.\u003c\/p\u003e\n\u003cp\u003eInstalled inline with your water treatment setup, the pump draws chemical solution from a reservoir and injects it through tubing into the water stream. The built-in 1\/4 kit streamlines the connection process, ensuring secure and leak-free operation within your treatment system.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you’ll notice immediate improvement in chemical dosing accuracy compared to manual or less precise pumps. The pump’s steady flow rate ensures your water treatment chemicals are delivered at the exact volume needed, optimizing system efficiency from day one.\u003c\/p\u003e\n\u003cp\u003eOver the following weeks, expect consistent performance with minimal adjustments. Its durable components reduce maintenance frequency, and the pump is designed to operate reliably even under continuous use. Routine inspection and chemical refills keep the system running smoothly long-term.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eStenner 17gpd Hiprs Pump – Provides precise, high-pressure resistant chemical dosing\u003c\/li\u003e\n  \u003cli\u003e1\/4 Kit – Includes essential fittings and tubing for secure chemical feed connections\u003c\/li\u003e\n  \u003cli\u003eRobust Housing – Protects internal components from environmental wear and chemical exposure\u003c\/li\u003e\n  \u003cli\u003e220v Motor – Ensures consistent power supply compatible with standard electrical setups\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eMount the pump securely near your chemical reservoir within reach of the water treatment system.\u003c\/li\u003e\n  \u003cli\u003eConnect the included 1\/4 tubing kit from the chemical container to the pump inlet and from the pump outlet to the injection point.\u003c\/li\u003e\n  \u003cli\u003eEnsure all fittings are tight to prevent leaks and check for proper tubing placement.\u003c\/li\u003e\n  \u003cli\u003ePower the pump using a compatible 220v supply, confirming voltage matches your setup.\u003c\/li\u003e\n  \u003cli\u003eAdjust the flow rate settings on the pump as needed to match your system’s chemical dosing requirements.\u003c\/li\u003e\n  \u003cli\u003eMonitor the pump during initial operation for any irregularities or leaks.\u003c\/li\u003e\n  \u003cli\u003ePerform routine inspections and refill chemical solution as required for continuous operation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt with high-quality materials to withstand harsh chemicals and pressure variations\u003c\/li\u003e\n  \u003cli\u003eBacked by a trusted vendor specializing in water softening and treatment solutions\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for chemical feed applications, ensuring optimal fit and function\u003c\/li\u003e\n  \u003cli\u003eCompatible with standard 220v power, making it easy to integrate into existing systems\u003c\/li\u003e\n  \u003cli\u003eLightweight and compact for versatile installation options without sacrificing durability\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this pump compatible with all types of chemicals?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most common water treatment chemicals but always verify chemical compatibility with the pump materials before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should the pump be maintained?\u003c\/strong\u003e\u003cbr\u003eRegular maintenance every few months is recommended, including checking tubing and fittings for wear or leaks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this pump be used in residential water softening systems?\u003c\/strong\u003e\u003cbr\u003eYes, it is suitable for both residential and light industrial water treatment applications requiring precise chemical dosing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat electrical requirements does this pump have?\u003c\/strong\u003e\u003cbr\u003eThe pump operates on 220v power; ensure your supply matches to avoid damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs installation complicated?\u003c\/strong\u003e\u003cbr\u003eThe included 1\/4 kit simplifies installation, but professional assistance is recommended for complex systems.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this high-precision chemical feed pump to your cart and keep your water treatment running smoothly with accurate, consistent chemical dosing.\u003c\/p\u003e\u003c!--wsp-xsell-v1--\u003e\u003cdiv class=\"wsp-xsell\" style=\"margin-top:18px;\"\u003e\n\u003ch2\u003eComplete your system\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/filter-cartridges\"\u003eReplacement filters \u0026amp; cartridges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/resins-filter-media-chemicals\"\u003eMedia \u0026amp; chemicals\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/control-valves-parts\"\u003eParts \u0026amp; accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819822510133,"sku":"780851338242","price":1213.61,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/85mhp-series_1.jpg?v=1764174830"},{"product_id":"85mhp17-110-b-stenner-17-gpd-hiprs-pmp-w-1-4-kit-110v-85mjh2a2staa","title":"85MHP17-110-B, Stenner 17 gpd Hiprs Pmp w\/1\/4 Kit, 110v, 85MJH2A2STAA","description":"\u003c!--wsp-trust-v1--\u003e\u003cdiv class=\"wsp-trust\" style=\"border:1px solid #e5e7eb;border-radius:10px;padding:12px 14px;margin:0 0 14px;background:#f9fafb;font-size:14px;\"\u003e\n\u003cstrong\u003eWhy buy from Water Softener Plus\u003c\/strong\u003e\u003cbr\u003e✔ US-based water treatment specialists   ✔ Ships nationwide \u0026amp; worldwide   ✔ Buy now, pay over time with Shop Pay\u003cbr\u003e✔ Free shipping on US orders over $1,000   ✔ Secure checkout   ✔ Easy returns   ✔ Free expert sizing help — call \u003ca href=\"tel:+18136211985\"\u003e813-621-1985\u003c\/a\u003e   ✔ Free install \u0026amp; service \u003ca href=\"\/zh-hans-as\/manuals\"\u003emanuals\u003c\/a\u003e included\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump for Precise Water Treatment and Enhanced System Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe 85MHP17-110-B Stenner 17 GPD Hiprs Pump with 1\/4 Kit is engineered to deliver consistent chemical dosing for water treatment systems. Unlike typical pumps, this model offers high precision and durability, making it ideal for managing chemical feeds in residential and commercial applications. Designed for seamless integration, it ensures your water softener or filtration setup operates safely and efficiently with minimal maintenance.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eDelivers accurate chemical dosing to maintain optimal water quality\u003c\/li\u003e\n  \u003cli\u003eEnhances system reliability by preventing overdosing or chemical waste\u003c\/li\u003e\n  \u003cli\u003eBuilt with durable components for long-lasting performance in demanding environments\u003c\/li\u003e\n  \u003cli\u003eCompatible with various chemicals used in water softening and treatment processes\u003c\/li\u003e\n  \u003cli\u003eCompact design with included 1\/4\" kit for easy installation and space-saving setup\u003c\/li\u003e\n  \u003cli\u003eOperates on standard 110v power, ensuring broad compatibility and convenience\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThis chemical feed pump precisely meters and injects chemicals into your water treatment system at a consistent rate of 17 gallons per day. By controlling the chemical feed, it helps maintain balanced water chemistry, preventing scale buildup and corrosion. The pump’s motor drives a diaphragm or piston mechanism that ensures steady chemical flow, essential for effective water softening or disinfection.\u003c\/p\u003e\n\u003cp\u003eInstalled inline with your water softener or filtration system, the pump draws chemical solution from a reservoir and delivers it directly into the water stream, improving system efficiency and water quality without manual intervention.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eImmediately after installation, you will notice smooth, precise chemical dosing that supports your system’s optimal operation. Over the first few days and weeks, the pump will establish consistent flow rates, helping to stabilize water treatment results. Its robust design minimizes downtime and maintenance needs, allowing you to rely on it for continuous, accurate chemical feed without frequent adjustments.\u003c\/p\u003e\n\u003cp\u003eLong-term, the pump maintains performance with minimal wear, provided routine inspections and fluid checks are conducted. Its compatibility with common chemical solutions makes it a versatile choice for various water softening and treatment applications.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eHigh-precision dosing motor – ensures accurate chemical delivery at 17 GPD\u003c\/li\u003e\n  \u003cli\u003eDurable chemical-resistant housing – protects internal components against corrosive fluids\u003c\/li\u003e\n  \u003cli\u003e1\/4\" tubing and fittings kit – simplifies installation and secure chemical flow connection\u003c\/li\u003e\n  \u003cli\u003eStandard 110v electrical components – compatible with typical power supplies for easy setup\u003c\/li\u003e\n  \u003cli\u003eSealed diaphragm assembly – prevents leaks and maintains consistent pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eMount the pump securely near your water treatment system, ensuring easy access to power and chemical reservoir.\u003c\/li\u003e\n  \u003cli\u003eConnect the supplied 1\/4\" tubing from the chemical reservoir to the pump inlet and from the outlet to the injection point on your water system.\u003c\/li\u003e\n  \u003cli\u003eVerify all connections are tight and leak-free before powering the unit.\u003c\/li\u003e\n  \u003cli\u003ePlug the pump into a 110v power source and switch it on; observe the pump cycles to confirm operation.\u003c\/li\u003e\n  \u003cli\u003ePeriodically check chemical levels and tubing integrity to maintain consistent dosing performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered by Stenner, a trusted name in chemical feed pumps known for reliability and precision\u003c\/li\u003e\n  \u003cli\u003eConstructed with chemical-resistant materials for enhanced durability in harsh water treatment environments\u003c\/li\u003e\n  \u003cli\u003eDesigned to fit seamlessly within a wide range of water softener and chemical feed systems\u003c\/li\u003e\n  \u003cli\u003eSupported by Water Softener Plus, ensuring expert guidance and product support\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this pump compatible with all chemical feed solutions?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most common water treatment chemicals, but always verify chemical compatibility with pump materials before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I perform maintenance on the pump?\u003c\/strong\u003e\u003cbr\u003eRegularly inspect tubing and chemical levels every few weeks; full pump servicing is typically needed annually depending on usage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install the pump myself?\u003c\/strong\u003e\u003cbr\u003eYes, the pump comes with a 1\/4\" kit and straightforward instructions, but ensure electrical connections comply with local safety codes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating voltage does the pump require?\u003c\/strong\u003e\u003cbr\u003eThis model operates on standard 110v power, suitable for most residential and commercial settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the pump safe for continuous use?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed for continuous operation to maintain consistent chemical feed without overheating or failure.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e\u003c!--wsp-xsell-v1--\u003e\u003cdiv class=\"wsp-xsell\" style=\"margin-top:18px;\"\u003e\n\u003ch2\u003eComplete your system\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/filter-cartridges\"\u003eReplacement filters \u0026amp; cartridges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/resins-filter-media-chemicals\"\u003eMedia \u0026amp; chemicals\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/control-valves-parts\"\u003eParts \u0026amp; accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819822706741,"sku":"780851338241","price":1182.85,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/85mhp-series_2.jpg?v=1764174833"},{"product_id":"45mhp10-110-stenner-100psi-10gpd-w-1-4-kit-110v-45mjh2a1s","title":"45MHP10-110, Stenner 100psi, 10gpd, w\/1\/4 Kit, 110v, 45MJH2A1S","description":"\u003c!--wsp-trust-v1--\u003e\u003cdiv class=\"wsp-trust\" style=\"border:1px solid #e5e7eb;border-radius:10px;padding:12px 14px;margin:0 0 14px;background:#f9fafb;font-size:14px;\"\u003e\n\u003cstrong\u003eWhy buy from Water Softener Plus\u003c\/strong\u003e\u003cbr\u003e✔ US-based water treatment specialists   ✔ Ships nationwide \u0026amp; worldwide   ✔ Buy now, pay over time with Shop Pay\u003cbr\u003e✔ Free shipping on US orders over $1,000   ✔ Secure checkout   ✔ Easy returns   ✔ Free expert sizing help — call \u003ca href=\"tel:+18136211985\"\u003e813-621-1985\u003c\/a\u003e   ✔ Free install \u0026amp; service \u003ca href=\"\/zh-hans-as\/manuals\"\u003emanuals\u003c\/a\u003e included\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump for Precise Water Treatment and System Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDesigned to deliver consistent chemical dosing, the 45MHP10-110 Stenner pump offers a dependable solution for water treatment challenges. This chemical feed pump stands out with its high-pressure capacity and efficient 10 gallons per day output, ensuring your water system operates smoothly and safely. Engineered to meet the demands of industrial and residential water softening, it integrates seamlessly with existing setups to enhance overall system performance.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures accurate chemical dosing to maintain water quality and system balance\u003c\/li\u003e\n  \u003cli\u003eOperates reliably under pressures up to 100 psi, suitable for demanding water treatment environments\u003c\/li\u003e\n  \u003cli\u003eDelivers up to 10 gallons per day for consistent feed rates tailored to your system’s needs\u003c\/li\u003e\n  \u003cli\u003eIncludes a convenient 1\/4\" installation kit for quick and secure setup\u003c\/li\u003e\n  \u003cli\u003ePowered by 110v for compatibility with standard electrical systems\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight design reduces strain on mounting and plumbing points\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe 45MHP10-110 chemical feed pump operates by drawing treatment chemicals from a reservoir and injecting them precisely into your water system. Its diaphragm-driven mechanism provides steady flow and pressure, ensuring chemicals are metered accurately without fluctuations. This consistent dosing helps prevent scaling, corrosion, and bacterial growth within your water softener or filtration system.\u003c\/p\u003e\n\u003cp\u003eBy maintaining chemical balance, the pump supports optimal operation of water treatment components, extending their lifespan and improving overall water quality.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eUpon installation, you will notice immediate improvement in chemical delivery accuracy, reducing manual adjustments and chemical waste. During the first days and weeks, the pump stabilizes dosing rates while you monitor system performance to ensure optimal settings. Over time, expect reliable operation with minimal maintenance thanks to its durable construction and quality components.\u003c\/p\u003e\n\u003cp\u003eRoutine checks and occasional tubing inspections will keep the pump functioning efficiently for long-term use.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eDiaphragm Pump Assembly – provides precise chemical injection and pressure handling up to 100 psi\u003c\/li\u003e\n  \u003cli\u003e1\/4\" Installation Kit – includes tubing and fittings for secure, leak-free connections\u003c\/li\u003e\n  \u003cli\u003eElectric Motor (110v) – powers the pump with consistent, energy-efficient operation\u003c\/li\u003e\n  \u003cli\u003eControl Valve – regulates chemical flow to maintain exact dosing requirements\u003c\/li\u003e\n  \u003cli\u003eDurable Housing – protects internal components from environmental factors and wear\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eSecurely mount the pump near your chemical reservoir and water system.\u003c\/li\u003e\n  \u003cli\u003eConnect the 1\/4\" tubing from the chemical source to the pump inlet and from the pump outlet to your water system injection point.\u003c\/li\u003e\n  \u003cli\u003ePlug the pump into a 110v power source and verify electrical safety standards.\u003c\/li\u003e\n  \u003cli\u003eAdjust the flow rate settings according to your system’s chemical dosing requirements.\u003c\/li\u003e\n  \u003cli\u003eRegularly inspect tubing and fittings for leaks or wear, replacing parts as needed.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt with high-quality materials for long-lasting durability and dependable performance\u003c\/li\u003e\n  \u003cli\u003eManufactured by Water Softener Plus, a trusted vendor specializing in water treatment components\u003c\/li\u003e\n  \u003cli\u003eDesigned to integrate seamlessly with various water softener and filtration systems\u003c\/li\u003e\n  \u003cli\u003eOffers precise control of chemical dosing to optimize water treatment efficiency\u003c\/li\u003e\n  \u003cli\u003eLightweight design simplifies installation without compromising robustness\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this pump compatible with all water softener systems?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most standard water softeners and chemical dosing setups, especially those requiring up to 100 psi pressure and 10 gpd feed rates.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I perform maintenance?\u003c\/strong\u003e\u003cbr\u003eRoutine inspections every few months are recommended, focusing on tubing integrity and pump operation to ensure continued accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the pump handle corrosive chemicals?\u003c\/strong\u003e\u003cbr\u003eThe pump is designed for typical water treatment chemicals, but verify chemical compatibility with manufacturer guidelines before use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage does this pump require?\u003c\/strong\u003e\u003cbr\u003eThis model operates on 110v, suitable for standard residential and light industrial power supplies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs professional installation necessary?\u003c\/strong\u003e\u003cbr\u003eWhile DIY installation is possible with the included kit, professional setup is recommended for optimal performance and safety.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e\u003c!--wsp-xsell-v1--\u003e\u003cdiv class=\"wsp-xsell\" style=\"margin-top:18px;\"\u003e\n\u003ch2\u003eComplete your system\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/filter-cartridges\"\u003eReplacement filters \u0026amp; cartridges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/resins-filter-media-chemicals\"\u003eMedia \u0026amp; chemicals\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/control-valves-parts\"\u003eParts \u0026amp; accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819822903349,"sku":"780851338213","price":1213.65,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/45mhp-series.jpg?v=1764174834"},{"product_id":"85mphp17-110-b-stenner-17-gpd-pmp-w-1-4-kit-110v-85mfh2a2suaa","title":"85MPHP17-110-B, Stenner 17 gpd Pmp w\/1\/4 Kit, 110v, 85MFH2A2SUAA","description":"\u003c!--wsp-trust-v1--\u003e\u003cdiv class=\"wsp-trust\" style=\"border:1px solid #e5e7eb;border-radius:10px;padding:12px 14px;margin:0 0 14px;background:#f9fafb;font-size:14px;\"\u003e\n\u003cstrong\u003eWhy buy from Water Softener Plus\u003c\/strong\u003e\u003cbr\u003e✔ US-based water treatment specialists   ✔ Ships nationwide \u0026amp; worldwide   ✔ Buy now, pay over time with Shop Pay\u003cbr\u003e✔ Free shipping on US orders over $1,000   ✔ Secure checkout   ✔ Easy returns   ✔ Free expert sizing help — call \u003ca href=\"tel:+18136211985\"\u003e813-621-1985\u003c\/a\u003e   ✔ Free install \u0026amp; service \u003ca href=\"\/zh-hans-as\/manuals\"\u003emanuals\u003c\/a\u003e included\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eReliable Chemical Feed Pump for Precise Water Treatment and System Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe 85MPHP17-110-B Stenner 17 GPD Pump with 1\/4\" Kit and 110v power is engineered to deliver consistent, accurate chemical dosing for your water treatment needs. Unlike generic pumps, this model ensures precise flow control and durability, making it a dependable choice for maintaining optimal system performance. Designed for use in chemical feed pump applications, it addresses common challenges like uneven dosing and pump failure with advanced build quality.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures consistent chemical dosing for balanced water treatment results\u003c\/li\u003e\n  \u003cli\u003eEnhances system reliability by minimizing downtime through durable construction\u003c\/li\u003e\n  \u003cli\u003eReduces maintenance frequency with corrosion-resistant components\u003c\/li\u003e\n  \u003cli\u003eImproves safety by preventing chemical overfeed and system damage\u003c\/li\u003e\n  \u003cli\u003eFacilitates easy integration with existing water softener and filtration setups\u003c\/li\u003e\n  \u003cli\u003eCompact design saves space while delivering up to 17 gallons per day capacity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThis Stenner chemical feed pump operates by drawing chemical solution from a reservoir and delivering a precise amount into your water system, ensuring optimal treatment levels. Powered by a reliable 110v motor, it maintains a steady flow rate up to 17 gallons per day, ideal for consistent chemical feed applications.\u003c\/p\u003e\n\u003cp\u003eThe included 1\/4\" tubing kit simplifies installation and ensures secure connections, while the pump’s internal mechanisms are designed to resist corrosion and wear, helping it perform reliably in demanding water treatment environments.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eImmediately after installation, you’ll notice smooth, steady chemical dosing with minimal manual adjustment required. The pump’s precision helps stabilize water quality by maintaining correct chemical levels without fluctuation.\u003c\/p\u003e\n\u003cp\u003eOver the first few weeks, the system will settle into routine operation with reliable flow rates and reduced risk of chemical spikes. Long-term, expect a low-maintenance experience with durable components that withstand typical wear and corrosion, extending the pump’s service life in your treatment system.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStenner 17 GPD Pump Unit\u003c\/strong\u003e – Provides consistent chemical flow with precision dosing technology\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e110v Motor\u003c\/strong\u003e – Delivers reliable power for continuous operation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e1\/4\" Tubing Kit\u003c\/strong\u003e – Ensures secure chemical feed connections and ease of installation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCorrosion-Resistant Pump Housing\u003c\/strong\u003e – Protects internal components for extended durability\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSealed Drive Mechanism\u003c\/strong\u003e – Prevents leaks and reduces maintenance requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eMount the pump securely near your chemical reservoir or treatment system.\u003c\/li\u003e\n  \u003cli\u003eConnect the supplied 1\/4\" tubing from the chemical container to the pump inlet and from the outlet to the feed point in your water system.\u003c\/li\u003e\n  \u003cli\u003ePlug the pump into a 110v power source, ensuring proper electrical safety measures.\u003c\/li\u003e\n  \u003cli\u003eAdjust the flow rate settings to match your system’s chemical dosing requirements, referring to the pump’s calibration guide.\u003c\/li\u003e\n  \u003cli\u003ePeriodically inspect tubing and pump components for wear or leaks and perform routine cleaning as recommended.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt with high-quality materials for long-lasting, reliable chemical feed performance\u003c\/li\u003e\n  \u003cli\u003eManufactured by a trusted vendor known for durable water treatment components\u003c\/li\u003e\n  \u003cli\u003eSpecifically designed to integrate seamlessly with common water softener and filtration systems\u003c\/li\u003e\n  \u003cli\u003eCompact and lightweight design simplifies installation without sacrificing capacity\u003c\/li\u003e\n  \u003cli\u003eBacked by years of proven performance in demanding chemical feed pump applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this pump compatible with standard water softener systems?\u003c\/strong\u003e\u003cbr\u003eYes, the 85MPHP17-110-B is designed to work effectively with most water softener and treatment setups requiring chemical feed pumps.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often should I perform maintenance on this pump?\u003c\/strong\u003e\u003cbr\u003eRoutine inspection every 3–6 months is recommended to check tubing integrity and clean pump components, ensuring optimal operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan the pump handle different types of chemical solutions?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with a range of common treatment chemicals, but always verify chemical compatibility with the pump materials before use.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat operating conditions are ideal for this pump?\u003c\/strong\u003e\u003cbr\u003eThe pump performs best within standard indoor water treatment environments with stable temperature and power supply.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs installation complicated for someone without technical experience?\u003c\/strong\u003e\u003cbr\u003eThe included 1\/4\" tubing kit and clear instructions make installation straightforward, but professional assistance is recommended if unsure.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e\u003c!--wsp-xsell-v1--\u003e\u003cdiv class=\"wsp-xsell\" style=\"margin-top:18px;\"\u003e\n\u003ch2\u003eComplete your system\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/filter-cartridges\"\u003eReplacement filters \u0026amp; cartridges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/resins-filter-media-chemicals\"\u003eMedia \u0026amp; chemicals\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/zh-hans-as\/collections\/control-valves-parts\"\u003eParts \u0026amp; accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":44819822936117,"sku":"780851338243","price":848.09,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/85mphp-series.jpg?v=1764174835"},{"product_id":"stenner-fp-series-tank-or-wall-mt-kit","title":"Stenner FP Series Tank or Wall Mt. Kit","description":"\u003cp\u003eThe Stenner FP Series Tank or Wall Mount Kit provides the hardware needed to securely mount a Stenner FP Series chemical feed pump, either on top of a solution tank or directly to a wall. A solid mounting foundation keeps the metering pump stable, level, and properly positioned for reliable, repeatable chemical injection, which is essential to consistent water treatment results.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGenuine Stenner FP Series mounting kit\u003c\/li\u003e\n\u003cli\u003eConfigurable for tank-top or wall mounting\u003c\/li\u003e\n\u003cli\u003eSecures the FP Series peristaltic feed pump\u003c\/li\u003e\n\u003cli\u003eReplacement-part category hardware\u003c\/li\u003e\n\u003cli\u003eSupports clean, organized chemical feed installations\u003c\/li\u003e\n\u003cli\u003eLightweight and easy to install\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eAbout Chemical Feed Pump Mounting\u003c\/h3\u003e\u003cp\u003eStenner peristaltic pumps are widely used throughout water treatment to inject precise, metered doses of solutions such as chlorine for disinfection, soda ash for pH adjustment, peroxide for oxidation, and various other chemicals. Because these pumps dose continuously or on demand to maintain water quality, how they are mounted matters more than it might first appear. Mounting the pump correctly, whether on top of the chemical solution tank or on a nearby wall, keeps the suction and discharge tubing runs short and well organized, simplifies routine maintenance access for tube and component changes, and helps the pump operate exactly as designed without strain on its fittings or tubing.\u003c\/p\u003e\u003cp\u003eThis kit is a practical accessory for new installations as well as for replacing damaged, worn, or missing mounting hardware on an existing Stenner FP Series setup. Choose the mounting configuration that best fits your equipment layout and available space, and position the pump so that the suction tubing can reach down into the solution tank and the discharge tubing can route cleanly to the injection point in your water line. Keeping these runs short and supported reduces the chance of kinks, leaks, or air locks that can disrupt accurate dosing. Before installing, confirm that the kit is compatible with your specific Stenner FP Series pump model, and mount the assembly securely to a stable surface so the pump remains firmly in place throughout its service life. Whether you are commissioning a new chemical feed installation or refreshing an aging one, this mounting kit is an inexpensive way to ensure your Stenner FP Series pump stays securely positioned for accurate, trouble-free dosing over the long term.\u003c\/p\u003e","brand":"G.h. Stenner \u0026 Co. Inc.#","offers":[{"title":"Default Title","offer_id":45668813733941,"sku":"FP-MOUNTING KIT","price":39.27,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fp-mounting-plate.jpg?v=1782678796"},{"product_id":"stenner-motor-120-volt","title":"Stenner Motor, 120 Volt","description":"\u003cp\u003eRestore your chemical feed pump to full operation with the Stenner 120-Volt Motor (STPM6081D) from Water Softener Plus. The motor is the driving force behind a Stenner peristaltic pump, turning the roller assembly that squeezes the pump tube to deliver precise, repeatable doses of treatment chemical. When that motor wears out or fails, the entire dosing process stops, making a quality replacement essential to keeping disinfection and treatment systems on schedule.\u003c\/p\u003e\u003cp\u003eStenner peristaltic pumps are prized in water treatment for their accuracy and chemical compatibility. Because the fluid only ever contacts the pump tube, these pumps handle aggressive chemistries like chlorine and other disinfectants cleanly, with no internal valves or seals to corrode and fail. The motor's steady, controlled rotation is what translates into the consistent dose rates these systems depend on for effective, reliable treatment day after day.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e120-volt replacement motor for Stenner peristaltic feed pumps\u003c\/li\u003e\n\u003cli\u003eGenuine Stenner brand replacement part for reliable fit and function\u003c\/li\u003e\n\u003cli\u003eDrives the roller assembly that delivers accurate chemical dosing\u003c\/li\u003e\n\u003cli\u003eWeighs approximately 4.70 lbs\u003c\/li\u003e\n\u003cli\u003eRestores full performance to disinfection and treatment feed systems\u003c\/li\u003e\n\u003cli\u003eBuilt for continuous-duty operation in demanding feed applications\u003c\/li\u003e\n\u003cli\u003eSupplied by Water Softener Plus for dependable sourcing\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eA failed motor is one of the more disruptive failures a feed system can experience, because without it the pump cannot dose at all and treatment simply stops. In chlorination and other disinfection applications, that interruption can directly affect water safety and quality, so getting the system back online promptly with the correct motor is a priority for any operator.\u003c\/p\u003e\u003cp\u003eKeeping a healthy motor in service protects the reliability of your entire feed system. Whether you are performing scheduled maintenance or responding to a failure, fitting the correct 120-volt Stenner motor returns your pump to dependable operation. For well owners, treatment plant operators, and service technicians, this genuine replacement motor is the straightforward path back to accurate, uninterrupted chemical feed and the consistent water quality it supports. Stocking a genuine replacement motor like this one is smart insurance for any operation that depends on continuous chemical feed, keeping costly downtime to a minimum when service is eventually required. Fitting the correct motor returns the pump to full output and the treatment process to its normal, dependable rhythm without delay.\u003c\/p\u003e","brand":"G.h. Stenner \u0026 Co. Inc.#","offers":[{"title":"Default Title","offer_id":45668850171957,"sku":"STPM6081D","price":533.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stpm6081d.jpg?v=1782535651"},{"product_id":"2-innermost-quickpro™-pump-head","title":"#2 Innermost QuickPro™ Pump Head","description":"\u003cp\u003eThe #2 Innermost QuickPro Pump Head from Water Softener Plus is a genuine Stenner replacement designed for double-head peristaltic feed pumps. Supplied complete with #2 tubes, this innermost head assembly is the wear component that does the actual pumping, so keeping a fresh one on hand is key to maintaining accurate, uninterrupted chemical dosing in your treatment system.\u003c\/p\u003e\u003ch3\u003eHow the QuickPro Head Works\u003c\/h3\u003e\u003cp\u003eIn a Stenner peristaltic pump, the pump head holds the flexible tube against a set of rollers. As the rollers rotate, they compress and release the tube, drawing chemical in and pushing it out in precise, metered amounts with each revolution. The QuickPro design makes tube and head replacement fast and clean, minimizing downtime during routine service. On double-head pumps, the innermost #2 head occupies the inner position, and matching it correctly ensures both heads dose exactly as intended.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGenuine Stenner #2 Innermost QuickPro pump head\u003c\/li\u003e\n\u003cli\u003eDesigned for the inner position on double-head peristaltic pumps\u003c\/li\u003e\n\u003cli\u003eIncludes #2 tubes for the correct dose rate out of the box\u003c\/li\u003e\n\u003cli\u003eQuickPro design simplifies and speeds up tube replacement\u003c\/li\u003e\n\u003cli\u003eRestores accurate chemical feed and reduces service downtime\u003c\/li\u003e\n\u003cli\u003eHelps prevent dosing drift and tube ruptures from worn components\u003c\/li\u003e\n\u003cli\u003eSupplied by Water Softener Plus for dependable sourcing\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBecause the pump tube is a consumable that flexes with every single rotation of the rollers, periodic replacement of the head and tube assembly is normal preventive maintenance, not a sign of failure or defect. Staying ahead of that wear protects against tube ruptures that can leak chemical and against the gradual dosing drift that creeps in as a tube ages and loses its resilience.\u003c\/p\u003e\u003cp\u003eDouble-head pumps are often used where two chemicals must be fed, or where a higher combined dose rate is needed, so keeping both heads in good condition is essential to balanced treatment. For technicians and system owners running Stenner double-head pumps, this #2 Innermost QuickPro head keeps disinfection and feed systems dosing accurately and reliably, day in and day out, with a quick and clean replacement when the time comes. Keeping a spare head and tubes on hand means you can refresh the pump quickly during routine service, holding dosing accuracy steady and avoiding the interruptions that worn consumables eventually cause.\u003c\/p\u003e","brand":"Stenner","offers":[{"title":"Default Title","offer_id":45668850237493,"sku":"STQPA252-1","price":1.02,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stqpa252-1.jpg?v=1782535653"},{"product_id":"stenner-15-gallon-uv-gray-tank","title":"Stenner 15 Gallon UV Gray Tank","description":"\u003cp\u003eThe Stenner 15-Gallon UV Gray Solution Tank from Water Softener Plus provides safe, durable storage for the treatment chemicals your feed pump dispenses. Holding 15 gallons of solution, this tank gives chemical feed systems the reservoir capacity they need to run between refills, while its UV-stabilized gray construction protects both the contents and the tank itself from sunlight degradation over a long service life.\u003c\/p\u003e\u003cp\u003eA solution tank is more than a simple container. In a chemical feed system, it is the controlled source from which the pump draws disinfectant or other treatment chemicals, so its material quality and capacity directly affect reliability and convenience. UV stabilization is particularly important for tanks that may sit in well houses, outbuildings, garages, or partially lit areas, because untreated plastics can become brittle, cracked, and discolored when exposed to light over time. The gray, UV-resistant build helps the tank stay sound and serviceable for the long term.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e15-gallon capacity for extended chemical feed intervals\u003c\/li\u003e\n\u003cli\u003eUV-stabilized gray construction resists sunlight breakdown\u003c\/li\u003e\n\u003cli\u003eDesigned to pair with Stenner peristaltic chemical feed pumps\u003c\/li\u003e\n\u003cli\u003eDurable solution-tank build for dependable chemical storage\u003c\/li\u003e\n\u003cli\u003eReduces how often operators must mix and replenish solution\u003c\/li\u003e\n\u003cli\u003eLightweight at approximately 5.00 lbs when empty\u003c\/li\u003e\n\u003cli\u003eSupplied by Water Softener Plus for trusted sourcing\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eMatching the tank to a Stenner pump creates a clean, integrated feed setup for chlorination and other dosing applications common in well-water and treatment systems. A properly sized reservoir keeps the pump fed with a steady supply of solution and gives operators a clear view of how much chemical remains, which helps with planning refills before the tank runs dry and treatment is interrupted.\u003c\/p\u003e\u003cp\u003eThe 15-gallon size strikes a practical balance between footprint and refill frequency, large enough to extend the interval between refills meaningfully, yet compact enough to fit most equipment rooms and well houses. For well owners and service professionals building or maintaining a chemical feed system, this Stenner solution tank is a reliable, purpose-built choice that supports consistent, trouble-free dosing. Pairing it with a matched Stenner pump and tube assembly completes a clean, reliable feed setup that operators can count on to deliver steady, accurate dosing throughout each refill interval. Its UV-stabilized build means it can serve in well houses and outbuildings without the brittleness and discoloration that shorten the life of ordinary tanks.\u003c\/p\u003e","brand":"G.h. Stenner \u0026 Co. Inc.#","offers":[{"title":"Default Title","offer_id":45668850303029,"sku":"STS15GC","price":483.4,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/sts15gc.jpg?v=1782535655"},{"product_id":"stenner-2-adap-tube-hsng","title":"Stenner #2 Adap Tube Hsng","description":"\u003cp\u003eThe Stenner #2 Adapter Tube Housing (STUC1ATC2) from Water Softener Plus is a genuine replacement component for Stenner peristaltic feed pumps. The tube housing holds and positions the pump tube within the pump head, ensuring the rollers compress it correctly for accurate, repeatable chemical dosing. Sized for the #2 tube, this adapter housing keeps your feed pump delivering the dose rate it was originally set up for.\u003c\/p\u003e\u003cp\u003ePeristaltic pumps work by squeezing a flexible tube against a rotating roller assembly, and every part that holds that tube in place plays a role in dosing accuracy. If the tube housing is worn, cracked, or mismatched, the tube can shift or seat improperly, throwing off the dose and risking premature tube failure that leads to leaks and downtime. Replacing the housing with the correct genuine part keeps the geometry of the pump head exactly as the manufacturer intended.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGenuine Stenner #2 adapter tube housing\u003c\/li\u003e\n\u003cli\u003ePositions and secures the pump tube for proper roller contact\u003c\/li\u003e\n\u003cli\u003eMatched to the #2 tube size for correct dose delivery\u003c\/li\u003e\n\u003cli\u003eReplacement part that restores precise, reliable feed operation\u003c\/li\u003e\n\u003cli\u003eHelps prevent dosing drift and premature tube failure\u003c\/li\u003e\n\u003cli\u003eWeighs approximately 0.70 lbs\u003c\/li\u003e\n\u003cli\u003eSupplied by Water Softener Plus for dependable sourcing\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBecause Stenner pumps are commonly used to feed chlorine and other treatment chemicals in well-water and disinfection systems, dependable and accurate dosing is critical to consistent water quality and safety. A component as seemingly minor as the tube housing can have an outsized effect on performance if it is allowed to wear out, since it directly controls how the tube is presented to the rollers.\u003c\/p\u003e\u003cp\u003eRoutine replacement of wear components like the tube housing is part of keeping these systems running trouble-free over the long haul. For service technicians and system owners maintaining Stenner feed pumps, this #2 adapter tube housing is the right part to restore proper tube support and accurate chemical feed, helping your disinfection or treatment system continue delivering the protection it was designed to provide. Keeping a spare on hand is sensible preventive maintenance for any operation running Stenner pumps, ensuring you can quickly restore proper tube support and accurate dosing whenever wear or damage calls for it.\u003c\/p\u003e","brand":"G.h. Stenner \u0026 Co. Inc.#","offers":[{"title":"Default Title","offer_id":45668850368565,"sku":"STUC1ATC2","price":181.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/stuc1atc2.jpg?v=1782535658"}],"url":"https:\/\/watersoftenerplus.com\/zh-hans-as\/collections\/brand-stenner.oembed","provider":"Water Softener Plus","version":"1.0","type":"link"}