CABINET WATER SOFTENER
THE SPACE SAVER
It’s called a cabinet-style water softener because the inner workings and salt tank are confined to a single cabinet. Since this type of water softener tends to be bulky, you don’t want to move it around to clean it. Brine tank cleanout can be a difficult and messy chore. Water softener manufacturers recommend using evaporated water softener salt pellets, as they are lower in water-soluble matter. Use high purity water softener salt to keep your cabinet-style water softener working properly and save you a messy cleanout job. If you use a low purity water softener salt that is higher in insoluble matter, your softener may need to be cleaned frequently.
Clack Water Specialist Cabinet w/"C-Series" CS Meter Control, Bypass & Turbulator
ITEM SPECIFICATIONS
-
C-Series
-
Bypass
-
Turbulator
-
Water Specialist Cabinet
-
Residential Cabinet Softener
-
24000
-
CS-Program
-
Metered
Clack Water Specialist Cabinet w/"C-Series" CS Meter Control, Bypass & Turbulator
• Solid-state microprocessor with easy access front panel settings
• Three modes of operation; meter immediate, meter delayed, or time clock delayed
• Double backwash feature offers optimum regeneration, cleaning ability, and efficiency • 73 selectable pre-programmed regeneration cycles
• Days override feature; 1 – 28 days available • Backwash and brining ability to 21” diameter tanks
• Downflow/upflow regeneration • Stores system configuration and operation data in nonvolatile memory
• Coin Cell Lithium battery back-up with an 8 hour carryover
• Level VI 15-volt output DC power supply provides safe and easy installation
• Control valve design provides optimum service and backwash rates
• Pre or Post treated water regenerant refill
• Patented one-piece expanding seal spacer stack assembly U.S. Patent 6,402,944
• Patented linearly reciprocating piston operation U.S. Patent 6,444,127
• Reliable and proven DC drive WATER SPECIALIST CONTROL VALVE WS1CS shown with optional bypass Certified to NSF/ANSI 44, 61 and 372. Water Specialist 1” CS Control Specifications Options: Backwash Filter, Bypass, Weather Cover Compatible with the following typical concentrations of regenerants or chemicals: Sodium chloride, potassium chloride, potassium permanganate, sodium bisulfite, chlorine and chloramines
1. Noryl is a trademark of Sabic Innovative Plastics IP B.V. Company
2. Filter tank size calculated @ 10 gpm of backwash per square foot of bed area Inlet/Outlet Fittings................................................................................... ¾" to 1.5” NPS Cycles ...................................................................................................... up to 6 Valve Material ........................................................................................... Noryl (1) or equivalent Regeneration ............................................................................................ downflow/upflow FLOW RATES Service @15 psi drop (includes bypass and meter) ................... 27 gpm Backwash @ 25 psi drop (includes bypass) ............................... 27 gpm Cv Service .................................................................................... 7.0 Cv Backwash ............................................................................... 5.4 OPERATING PRESSURES Minimum/Maximum ..................................................................... 20 psi – 125 psi OPERATING TEMPERATURES Minimum/Maximum ..................................................................... 40º – 110º F METER Accuracy ...................................................................................... ± 5% Flow Rate Range.......................................................................... 0.25 – 27 gpm Gallon Range................................................................................ 20 – 50,000 gallons Totalizer........................................................................................ 1000 - 9,999,000 gallons DIMENSIONS & WEIGHT Distributor Pilot............................................................................ 1.050" OD Pipe (¾" NPS) Drain Line ..................................................................................... ¾” or 1” NPT Brine Line ..................................................................................... 3 /8” or ½” OD Poly Tube Mounting Base............................................................................. 2 ½” - 8 NPSM Height From Top Of Tank............................................................. 7 3 /8” Weight .......................................................................................... 4.5 lbs. ELECTRICAL SPECIFICATIONS POWER SUPPLY U.S. International Supply Voltage ..........................................................................100VAC to 120VAC......200VAC to 240VAC Supply Frequency.....................................................................50/60 Hz.......................50/60 Hz Output Voltage ..........................................................................15VDC..........................15VDC Output Current..........................................................................500 mA.........................500 mA TANK APPLICATIONS Water Softener............................................................................. 6” – 21” Diameter Water Filter (2).............................................................................. 6” – 21” Diameter CYCLES OF OPERATION (Softener Downflow) Cycle Range of times minutes 1. Backwash 1st (upflow) .............................................................. 6 - 16 2. Regenerate Draw/Slow Rinse (downflow) .............................. 45 - 75 3. Backwash 2nd (upflow) ............................................................. 3 - 12 4. Fast Rinse (downflow) ............................................................. 3 - 10 5. Regenerant Refill (in service with treated water).................... As Programmed 6. Service (downflow)
U.S. Patents: 6,402,944
• 6,444,127 Form No. 2607 • 3/
DESTROY 99.9% of HARMFUL MICROORGANISMS Add Viqua UV Light for Water Disinfection