{"title":"Fleck Valve Motors, Timers \u0026 Drives","description":"\u003cp\u003eFleck Valve Motors, Timers \u0026amp; Drives: Replacement parts that bring a water softener or filter control valve back to factory operation.\u003c\/p\u003e\u003cp\u003eThis collection has 16 products from brands including Fleck, priced from $32.82 to $941. Shipping is free anywhere in the USA.\u003c\/p\u003e\u003cp\u003eNot sure which one fits your system? Call us at 813-897-9971 or email watersoftenerplus@gmail.com with your model or a photo of the label, and we will match the right part.\u003c\/p\u003e","products":[{"product_id":"fl60304-13-fleck-3200-tmr-12dy-sep-time-fl-no-adj-60304-13","title":"Fleck 3200 Timer Valve with 12-day Separate Time — FL60304-13, Fleck 3200 Tmr, 12dy Sep Time Fl, No Adj, 60304-13","description":"\u003cp\u003e\u003cstrong\u003eReliable Fleck Valve Timer for Precise Water Softener Control and Maintenance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen it comes to managing your water softener system, the FL60304-13 Fleck 3200 TMR timer offers unmatched reliability and precision. Designed specifically for Fleck valve parts, this 12-day separate time clock ensures your system operates on an exact regeneration schedule without manual adjustments. Its no-adjustment design simplifies maintenance while enhancing system efficiency and longevity.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures accurate regeneration cycles to maintain optimal water softening performance\u003c\/li\u003e\n  \u003cli\u003eReduces manual intervention with a no-adjustment, preset timer for hassle-free operation\u003c\/li\u003e\n  \u003cli\u003eEnhances system reliability by preventing premature or delayed regeneration\u003c\/li\u003e\n  \u003cli\u003eCompatible with Fleck 3200 valve models, ensuring a perfect fit and seamless integration\u003c\/li\u003e\n  \u003cli\u003eDurable construction designed to withstand regular use and environmental factors\u003c\/li\u003e\n  \u003cli\u003eSupports separate timing for brine and rinse cycles, improving system efficiency\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe FL60304-13 timer functions as the control center for your water softener’s regeneration process. It operates on a 12-day separate time schedule, meaning it independently manages the timing of brine draw and rinse cycles to optimize salt and water usage. By precisely controlling when regeneration starts and stops, the timer ensures your resin bed is refreshed regularly, maintaining soft water quality throughout your home or facility.\u003c\/p\u003e\n\u003cp\u003eThis timer replaces manual or outdated clock systems, automating the softening process and reducing the risk of system downtime or inefficient operation due to incorrect timing.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you will notice your water softener regenerates consistently according to the preset 12-day schedule, which minimizes water and salt waste. During the first few days, you may observe improved water softness and system responsiveness. Over time, this timer helps extend the life of your water softener by maintaining ideal regeneration intervals without the need for frequent adjustments.\u003c\/p\u003e\n\u003cp\u003eWith minimal maintenance required, the timer provides long-term reliability, allowing you to focus on other household or operational priorities without worrying about your water treatment system’s timing accuracy.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eFleck 3200 Timer Mechanism – Precisely controls regeneration intervals for consistent softening\u003c\/li\u003e\n  \u003cli\u003e12-Day Separate Time Clock – Allows independent scheduling of brine and rinse cycles for efficiency\u003c\/li\u003e\n  \u003cli\u003eDurable Housing – Protects internal components from dust and moisture, ensuring longevity\u003c\/li\u003e\n  \u003cli\u003eNon-Adjustable Setting – Pre-configured timing reduces user error and simplifies setup\u003c\/li\u003e\n  \u003cli\u003eMounting Brackets and Connectors – Enables secure and easy installation onto compatible Fleck valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the water softener and unplug the system to ensure safety during installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing timer from the Fleck 3200 valve, noting the wiring and mounting setup.\u003c\/li\u003e\n  \u003cli\u003eInstall the FL60304-13 timer onto the valve using the provided brackets and connectors.\u003c\/li\u003e\n  \u003cli\u003eReconnect wiring according to the manufacturer’s guidelines to ensure proper function.\u003c\/li\u003e\n  \u003cli\u003ePower on the water softener and verify the timer initiates regeneration on its preset 12-day schedule.\u003c\/li\u003e\n  \u003cli\u003eMonitor the first regeneration cycle to confirm smooth operation and timing accuracy.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eCrafted for durability, this timer withstands regular system cycles and environmental exposure.\u003c\/li\u003e\n  \u003cli\u003eWater Softener Plus offers trusted Fleck valve parts backed by reliable customer support.\u003c\/li\u003e\n  \u003cli\u003eSpecifically designed to fit Fleck 3200 valves, ensuring compatibility and hassle-free installation.\u003c\/li\u003e\n  \u003cli\u003eEliminates the need for manual adjustments, reducing maintenance time and user error.\u003c\/li\u003e\n  \u003cli\u003eOptimizes water softener efficiency by managing separate brine and rinse timing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this timer compatible with all Fleck water softener models?\u003cbr\u003e\u003c\/strong\u003eThis timer is designed specifically for Fleck 3200 valve models and may not fit other series without modification.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHow often do I need to adjust or maintain the timer?\u003cbr\u003e\u003c\/strong\u003eThe timer comes pre-set with a 12-day cycle and requires no manual adjustment under normal operation; occasional cleaning to remove dust is recommended.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan I install this timer myself?\u003cbr\u003e\u003c\/strong\u003eIf you have basic technical skills and follow the installation steps carefully, you can install it safely; otherwise, consult a professional technician.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat happens if the timer stops working?\u003cbr\u003e\u003c\/strong\u003eIf the timer fails, your system may not regenerate properly; replacing it promptly will restore your water softener’s function.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eIs the timer affected by power outages?\u003cbr\u003e\u003c\/strong\u003eThe timer relies on electrical power; during outages, regeneration may be delayed until power is restored.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes the timer control salt or water usage directly?\u003cbr\u003e\u003c\/strong\u003eNo, it controls the timing of regeneration cycles, indirectly influencing salt and water consumption through cycle scheduling.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":44819850199093,"sku":"780851339037","price":185.06,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fl60304-13-r1200.jpg?v=1789601556"},{"product_id":"fl19659-1-fleck-motor-24v-1-30-rpm-19659-01","title":"Fleck 24V 1\/30 RPM Motor for Valve — FL19659-1, Fleck Motor 24v 1\/30 rpm, 19659-01","description":"\u003cp\u003e\u003cstrong\u003eReliable Fleck Motor 24v 1\/30 rpm for Efficient Water Softener Valve Operation\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eDesigned to optimize your water softener system’s performance, the FL19659-1 Fleck Motor 24v 1\/30 rpm offers a dependable and precise solution for valve actuation. Unlike generic replacements, this motor is engineered to fit Fleck valve parts perfectly, providing consistent operation and reducing the risk of system downtime. If you're looking for a durable, efficient motor that enhances your water treatment setup, this Fleck motor is the ideal choice.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures smooth and accurate valve control for consistent water softening cycles\u003c\/li\u003e\n  \u003cli\u003eProtects your water system from operational failures due to motor malfunction\u003c\/li\u003e\n  \u003cli\u003eEnhances system longevity by providing reliable, low-maintenance performance\u003c\/li\u003e\n  \u003cli\u003eWorks seamlessly with Fleck valve parts for easy integration and replacement\u003c\/li\u003e\n  \u003cli\u003eSupports energy-efficient 24v operation to reduce power consumption\u003c\/li\u003e\n  \u003cli\u003eCompact design fits easily into existing water softener setups without modification\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThis Fleck motor operates at 24 volts with a 1\/30 rpm speed, driving the valve actuator within your water softener system. It precisely rotates the valve to initiate regeneration cycles, ensuring that the softening resin is cleaned and recharged regularly. By controlling valve positioning, it regulates water flow through the softener, maintaining optimal water quality and system efficiency.\u003c\/p\u003e\n\u003cp\u003eIntegrated with Fleck valve parts, the motor’s smooth rotation prevents wear and tear, contributing to a longer service life for both the motor and valve assembly. Its steady, low-speed motion is ideal for sensitive water treatment components that require gentle handling.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eAfter installing the FL19659-1 Fleck Motor, you will notice immediate improvements in your water softener's responsiveness and cycle accuracy. The motor’s consistent operation helps eliminate valve sticking or misalignment issues, which can cause irregular water softening.\u003c\/p\u003e\n\u003cp\u003eWithin the first few days, your system will run more quietly and efficiently. Over weeks and months, you can expect dependable performance with minimal maintenance, reducing the need for frequent repairs or replacements in your water treatment system.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Torque Motor Assembly\u003c\/strong\u003e – Provides the necessary force to rotate the valve smoothly and accurately.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDurable 24v Electrical Components\u003c\/strong\u003e – Ensures consistent power delivery with energy efficiency.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecision Gear Mechanism\u003c\/strong\u003e – Controls rotation speed to 1\/30 rpm, matching valve timing requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact Housing\u003c\/strong\u003e – Protects internal parts from moisture and dust, enhancing durability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompatible Mounting Interface\u003c\/strong\u003e – Designed specifically for Fleck valve parts, allowing secure and easy installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the power supply to your water softener system before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing motor from the Fleck valve assembly by loosening mounting screws and disconnecting wiring.\u003c\/li\u003e\n  \u003cli\u003eAlign the FL19659-1 motor with the valve’s mounting interface and secure it with the original screws.\u003c\/li\u003e\n  \u003cli\u003eReconnect the electrical wiring, ensuring correct polarity and secure connections.\u003c\/li\u003e\n  \u003cli\u003eRestore power and run a test cycle to confirm the motor is operating smoothly and the valve cycles correctly.\u003c\/li\u003e\n  \u003cli\u003eMonitor the system for a full regeneration cycle to verify consistent performance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt with high-quality components designed for durability in demanding water treatment environments.\u003c\/li\u003e\n  \u003cli\u003eOffers a precise fit and compatibility with Fleck valve parts, eliminating installation guesswork.\u003c\/li\u003e\n  \u003cli\u003eBacked by Water Softener Plus, a trusted vendor specializing in reliable water treatment components.\u003c\/li\u003e\n  \u003cli\u003eOptimized for energy-efficient operation, helping reduce your system’s power usage.\u003c\/li\u003e\n  \u003cli\u003eEngineered to maintain consistent performance, supporting your water softener’s longevity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this motor compatible with all Fleck valve models?\u003c\/strong\u003e\u003cbr\u003eIt is designed specifically for Fleck valve parts matching the 19659-01 specification; verify your valve model before purchasing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I perform maintenance on this motor?\u003c\/strong\u003e\u003cbr\u003eRoutine inspection during regular water softener servicing is recommended, but the motor generally requires minimal maintenance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this motor myself?\u003c\/strong\u003e\u003cbr\u003eYes, with basic mechanical skills and following the installation steps carefully, most users can install this motor safely.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating conditions does this motor support?\u003c\/strong\u003e\u003cbr\u003eIt is built to function reliably within typical residential water softener environments, including standard temperature and humidity ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill this motor affect my water softener’s energy consumption?\u003c\/strong\u003e\u003cbr\u003eThe 24v design supports energy-efficient operation and should not significantly increase power usage.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this FL19659-1 Fleck Motor to your cart and keep your water flowing clean and consistent with every cycle.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":44819851542581,"sku":"780851339173","price":123.64,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fl19659-1_1d1ecedb-b719-4271-952a-6662671a1d12-r1200.jpg?v=1789600335"},{"product_id":"fl41543-fleck-drive-motor-115v-50-60hz-41543","title":"Fleck Drive Motor, 115V 50\/60HZ, 41543 (FL41543)","description":"\u003cp\u003e\u003cstrong\u003eReliable Fleck Drive Motor for Consistent Water Softener Performance\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen your water softener valve needs dependable power, the FL41543 Fleck Drive Motor delivers efficient and consistent operation. Designed specifically for Fleck valve parts, this 115V 50\/60HZ motor ensures your system runs smoothly without interruption. Its robust build addresses common issues like motor failure, giving you a safer and more reliable water treatment solution.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures consistent valve operation for uninterrupted water softening\u003c\/li\u003e\n  \u003cli\u003eCompatible with a wide range of Fleck valve parts for easy integration\u003c\/li\u003e\n  \u003cli\u003eDurable construction reduces the need for frequent replacements\u003c\/li\u003e\n  \u003cli\u003eOptimized for both 50 and 60HZ power supplies, fitting multiple regions\u003c\/li\u003e\n  \u003cli\u003eImproves overall system efficiency by maintaining precise motor control\u003c\/li\u003e\n  \u003cli\u003eLightweight design simplifies installation and handling\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe FL41543 Fleck Drive Motor powers the valve assembly in your water softener system, controlling the timing and movement necessary for regeneration cycles. By converting electrical energy into mechanical motion, it drives the valve to switch between service and regeneration modes accurately. This ensures your water softener operates at peak performance, delivering softened water consistently.\u003c\/p\u003e\n\u003cp\u003eIts compatibility with Fleck valve parts means it fits seamlessly into existing setups, replacing worn or faulty motors without complicated modifications.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you’ll notice your water softener responding promptly to regeneration demands, maintaining optimal water quality. In the first days and weeks, the motor runs quietly and reliably, handling frequent cycles without overheating or stalling. Over time, its durable design helps minimize maintenance needs, allowing your system to operate smoothly with fewer interruptions.\u003c\/p\u003e\n\u003cp\u003eRegular checks are still recommended to ensure longevity, but this motor’s build quality supports extended use under typical household conditions.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eElectric Motor Core – Provides the necessary torque and speed for valve operation\u003c\/li\u003e\n  \u003cli\u003eDurable Housing – Protects internal components from moisture and dust exposure\u003c\/li\u003e\n  \u003cli\u003ePrecision Gears – Facilitate smooth mechanical movement for accurate valve positioning\u003c\/li\u003e\n  \u003cli\u003eElectrical Connectors – Ensure stable power delivery compatible with 115V 50\/60HZ supplies\u003c\/li\u003e\n  \u003cli\u003eMounting Brackets – Enable secure attachment within the Fleck valve assembly\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off power and water supply to your water softener system.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing drive motor by disconnecting electrical wiring and unscrewing mounting brackets.\u003c\/li\u003e\n  \u003cli\u003eInstall the FL41543 motor by aligning it with the valve assembly and securing it with mounting hardware.\u003c\/li\u003e\n  \u003cli\u003eReconnect electrical wiring, ensuring correct polarity and secure connections.\u003c\/li\u003e\n  \u003cli\u003eRestore water supply and power, then run a test regeneration cycle to confirm proper operation.\u003c\/li\u003e\n  \u003cli\u003eMonitor the system during initial use for any unusual noises or malfunctions.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eBuilt with quality materials designed to withstand regular water softener demands\u003c\/li\u003e\n  \u003cli\u003eBacked by Water Softener Plus’s reputation for reliable, compatible Fleck valve parts\u003c\/li\u003e\n  \u003cli\u003eDesigned specifically for Fleck systems to ensure perfect fit and function\u003c\/li\u003e\n  \u003cli\u003eSupports both 50HZ and 60HZ electrical standards for versatile use\u003c\/li\u003e\n  \u003cli\u003eLightweight and compact, simplifying installation and maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this motor compatible with all Fleck valves?\u003c\/strong\u003e\u003cbr\u003eIt is compatible with most Fleck valve models that use the FL41543 motor specification; please verify your valve model before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this motor myself?\u003c\/strong\u003e\u003cbr\u003eYes, with basic electrical and mechanical skills, you can install it safely by following the outlined steps and ensuring power is off during installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat voltage does this motor require?\u003c\/strong\u003e\u003cbr\u003eThis motor operates on 115V and supports both 50HZ and 60HZ frequencies, suitable for many residential power supplies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I inspect the motor?\u003c\/strong\u003e\u003cbr\u003ePeriodic inspections every 6–12 months help ensure the motor remains clean and free of debris for optimal performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre there any special maintenance needs?\u003c\/strong\u003e\u003cbr\u003eRoutine cleaning and checking electrical connections are sufficient; no additional lubrication is typically required.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your water softener’s reliability today—add the FL41543 Fleck Drive Motor to your cart and keep your system running smoothly with consistent, efficient performance.\u003c\/p\u003e\n\u003c!--WSP-MANUAL-LINK--\u003e\u003cdiv class=\"wsp-manual-box\" style=\"border:1px solid #e2e2e2;border-radius:8px;padding:12px;margin:14px 0;background:#f7fbff;\"\u003e\n\u003cstrong\u003e📖 Free 130441 Cj101 Cj103 Instructions Manual (PDF)\u003c\/strong\u003e — owner's manual, installation \u0026amp; programming guide. \u003ca href=\"\/pages\/manual-130441-cj101-cj103-instructions\" rel=\"nofollow\"\u003e\u003cstrong\u003eDownload the manual →\u003c\/strong\u003e\u003c\/a\u003e\n\u003c\/div\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":44819854721077,"sku":"780851338934","price":192.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fl41543-fleck-drive-motor-115v-50-60hz-41543-hires-r1200.jpg?v=1789600580"},{"product_id":"fl16944-fleck-drive-motor-24v-60hz-2-rpm-16944","title":"Fleck Drive Motor 24v, 60hz, 2 rpm, 16944 (FL16944)","description":"\u003cp\u003e\u003cstrong\u003eReliable Fleck Drive Motor 24v – Enhance Your Water Softener’s Efficiency and Longevity\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eWhen your water softener’s drive motor falters, it can disrupt your entire system’s performance. The FL16944 Fleck Drive Motor 24v, 60hz, 2 rpm offers a dependable replacement designed specifically for Fleck valve parts, ensuring smooth and consistent operation. This motor is engineered to deliver precise control and durability, making it a trusted choice for maintaining optimal water treatment system functionality.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEnsures consistent valve operation for uninterrupted water softening performance\u003c\/li\u003e\n  \u003cli\u003eDelivers precise 2 rpm motor speed to maintain accurate regeneration cycles\u003c\/li\u003e\n  \u003cli\u003eReduces system downtime by providing a durable and long-lasting motor solution\u003c\/li\u003e\n  \u003cli\u003eCompatible with Fleck valve parts to simplify replacement and installation\u003c\/li\u003e\n  \u003cli\u003eOperates efficiently at 24v and 60hz, optimizing energy use within your water treatment setup\u003c\/li\u003e\n  \u003cli\u003eMinimizes wear and tear on water softener components through smooth motor function\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe FL16944 Fleck Drive Motor powers the control valve of your water softener, rotating the valve at a steady 2 revolutions per minute. This precise motion controls the timing and sequencing of regeneration cycles, which flush out hardness minerals and refresh the resin bed inside your softener. By maintaining accurate motor speed and torque, it ensures your system operates smoothly and efficiently, preventing interruptions in softened water supply.\u003c\/p\u003e\n\u003cp\u003eInstalled within the Fleck valve assembly, this motor converts electrical power into mechanical movement that drives the valve’s internal gears. Its compatible design means it integrates seamlessly with existing Fleck systems, preserving the integrity and reliability of your water treatment setup.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you’ll notice your water softener running with renewed consistency, eliminating irregular regeneration timing or valve malfunction issues. In the first few days, expect smooth transitions through the softening and regeneration phases without delays or unexpected shutdowns.\u003c\/p\u003e\n\u003cp\u003eOver the longer term, this motor offers dependable durability with minimal maintenance, reducing the need for frequent repairs or replacements. Properly installed and maintained, it can extend the lifespan of your Fleck valve assembly and maintain water softener efficiency for years to come.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eRobust 24v Motor Coil – Provides stable electrical performance for consistent operation\u003c\/li\u003e\n  \u003cli\u003ePrecision Gear Mechanism – Ensures accurate 2 rpm rotation speed integral to valve timing\u003c\/li\u003e\n  \u003cli\u003eDurable Housing – Protects internal components from moisture and mechanical wear\u003c\/li\u003e\n  \u003cli\u003eStandardized Mounting Interface – Facilitates straightforward compatibility with Fleck valve parts\u003c\/li\u003e\n  \u003cli\u003eSealed Electrical Connections – Prevents corrosion and maintains reliable power delivery\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off power and water supply to your water softener system before beginning installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing drive motor from the Fleck valve assembly carefully, noting the orientation and wiring connections.\u003c\/li\u003e\n  \u003cli\u003eInstall the FL16944 Fleck Drive Motor by aligning it with the valve’s mounting points and securing it firmly.\u003c\/li\u003e\n  \u003cli\u003eReconnect all electrical wiring according to the original configuration, ensuring secure connections.\u003c\/li\u003e\n  \u003cli\u003eRestore power and water supply, then run a test cycle to confirm proper motor function and valve operation.\u003c\/li\u003e\n  \u003cli\u003eMonitor the system through a regeneration cycle to verify smooth and accurate valve movement.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eEngineered for quality and durability to withstand continuous water softener operation\u003c\/li\u003e\n  \u003cli\u003eSpecifically designed for Fleck valve parts, ensuring perfect fit and compatibility\u003c\/li\u003e\n  \u003cli\u003eOffered by Water Softener Plus, a trusted vendor specializing in reliable water treatment components\u003c\/li\u003e\n  \u003cli\u003eOptimized for efficient power use at 24v, reducing electrical load on your system\u003c\/li\u003e\n  \u003cli\u003eSupports seamless integration within existing water softener setups to maintain system integrity\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs this motor compatible with all Fleck water softener models?\u003c\/strong\u003e\u003cbr\u003eThis FL16944 motor is designed to fit most Fleck valve parts that require a 24v, 2 rpm drive motor, but always verify your model for compatibility before purchase.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often does the drive motor need maintenance?\u003c\/strong\u003e\u003cbr\u003eWith proper installation, the motor requires minimal maintenance; periodic inspection during routine system checks is recommended.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this motor myself?\u003c\/strong\u003e\u003cbr\u003eIf you are comfortable working with electrical components and water softener systems, you can follow the step-by-step instructions; otherwise, consult a professional technician.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating conditions does this motor support?\u003c\/strong\u003e\u003cbr\u003eThe motor is designed for standard residential water softener environments operating at 24 volts and 60hz frequency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill replacing the motor affect my water softener warranty?\u003c\/strong\u003e\u003cbr\u003eCheck your system’s warranty terms; using genuine or compatible parts like this motor typically maintains warranty coverage.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your water softener’s reliability today—add the FL16944 Fleck Drive Motor 24v to your cart and keep your water flowing clean and consistent with trusted performance.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":44819856883765,"sku":"780851339161","price":194.55,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fl16944-fleck-drive-motor-24v-60hz-2-rpm-16944-hires-r1200.jpg?v=1789600237"},{"product_id":"fl90m-sxt-ph-90-91-95-sxt-power-head-62103-76","title":"SXT Power Head for Fleck 90\/91\/95 Valves — FL90M-SXT-PH, 90\/91\/95 SXT Power Head, 62103-76","description":"\u003c!--wsp-trust-v1--\u003e\u003cdiv class=\"wsp-trust\" style=\"border:1px solid #e5e7eb;border-radius:10px;padding:12px 14px;margin:0 0 14px;background:#f9fafb;font-size:14px;\"\u003e\n\u003cstrong\u003eWhy buy from Water Softener Plus\u003c\/strong\u003e\u003cbr\u003e✔ US-based water treatment specialists   ✔ Ships nationwide \u0026amp; worldwide   ✔ Buy now, pay over time with Shop Pay\u003cbr\u003e✔ Free shipping on all US orders   ✔ Secure checkout   ✔ Easy returns   ✔ Free expert sizing help — call 813-897-9971   ✔ Free install \u0026amp; service \u003ca href=\"\/manuals\"\u003emanuals\u003c\/a\u003e included\u003c\/div\u003e\u003cp\u003e\u003cstrong\u003eFL90M-SXT-PH Power Head: Enhance Your Fleck Control Valve Performance with Reliable Efficiency\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe FL90M-SXT-PH, designed specifically for 90, 91, and 95 SXT control valves, offers a dependable upgrade to your water softener or filtration system. Unlike generic power heads, this precision-engineered component ensures seamless integration with Fleck control valves and accessories, delivering consistent system performance and improved water treatment results. Its robust design helps reduce downtime and maintenance needs, making it a trusted choice for both residential and commercial water treatment setups.\u003c\/p\u003e\n\n\u003ch2\u003eKey Benefits\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eImproves control valve responsiveness for smoother system operation\u003c\/li\u003e\n  \u003cli\u003eEnhances water softener efficiency, leading to better water quality\u003c\/li\u003e\n  \u003cli\u003eReduces risk of valve failure with durable, high-quality construction\u003c\/li\u003e\n  \u003cli\u003eCompatible with multiple Fleck SXT models, simplifying parts management\u003c\/li\u003e\n  \u003cli\u003eEasy installation minimizes system downtime and service interruptions\u003c\/li\u003e\n  \u003cli\u003eSupports long-term reliability under continuous water treatment use\u003c\/li\u003e\n  \u003cli\u003eHelps maintain consistent water flow and pressure within your system\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow It Works\u003c\/h2\u003e\n\u003cp\u003eThe FL90M-SXT-PH power head acts as the central control unit for Fleck 90, 91, and 95 SXT valves, directing the valve’s cycles such as regeneration, backwash, and service modes. It houses the microprocessor and motor that operate the valve’s internal components, ensuring precise timing and smooth transitions. By accurately managing these cycles, it optimizes the water treatment process and maintains system efficiency.\u003c\/p\u003e\n\u003cp\u003eWhen installed, this power head communicates continuously with the valve assembly, regulating the flow of water through the system. This control reduces wear on the valve components and prevents common issues like valve sticking or improper regeneration, essential for maintaining clean, softened water.\u003c\/p\u003e\n\n\u003ch2\u003eWhat to Expect\u003c\/h2\u003e\n\u003cp\u003eOnce installed, you’ll notice your water softener or filtration system operating with improved consistency and fewer interruptions. The immediate effect is smoother valve cycling, which reduces noise and mechanical strain. Over the first few weeks, the system will stabilize, ensuring optimal regeneration timing that conserves salt and water usage.\u003c\/p\u003e\n\u003cp\u003eLong-term, the FL90M-SXT-PH power head is engineered for durability, reducing the frequency of repairs or replacements. Routine maintenance is straightforward, with most users experiencing reliable performance for years. Its robust design helps prevent common power head failures, contributing to the overall longevity of your Fleck control valve system.\u003c\/p\u003e\n\n\u003ch2\u003eWhat’s Inside\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMicroprocessor Unit\u003c\/strong\u003e – Controls valve timing and cycle management for precise operation\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMotor Assembly\u003c\/strong\u003e – Drives the mechanical movements of the valve components smoothly and reliably\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSealed Housing\u003c\/strong\u003e – Protects internal electronics from moisture and debris, ensuring long-lasting performance\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Interface\u003c\/strong\u003e – Enables secure attachment to Fleck 90\/91\/95 SXT valves for seamless communication\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eControl Panel\u003c\/strong\u003e – Allows easy programming and monitoring of the power head’s functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003col\u003e\n  \u003cli\u003eTurn off the water supply to your water softener or filtration system before starting installation.\u003c\/li\u003e\n  \u003cli\u003eRemove the existing power head carefully by disconnecting the electrical connections and unfastening the mounting screws.\u003c\/li\u003e\n  \u003cli\u003ePosition the FL90M-SXT-PH power head onto the Fleck 90, 91, or 95 SXT valve body, ensuring all connectors align properly.\u003c\/li\u003e\n  \u003cli\u003eSecure the power head using the provided screws or clips to prevent movement or leaks.\u003c\/li\u003e\n  \u003cli\u003eReconnect the electrical wiring as per the manufacturer’s instructions, verifying all connections are tight and correct.\u003c\/li\u003e\n  \u003cli\u003eTurn the water supply back on and perform a manual regeneration cycle to confirm proper function.\u003c\/li\u003e\n  \u003cli\u003eProgram the control panel according to your system’s requirements and consult your user manual for specific settings.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2\u003eWhy Choose This Product\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eManufactured to meet or exceed OEM standards for Fleck control valves, ensuring perfect compatibility\u003c\/li\u003e\n  \u003cli\u003eBuilt with durable materials designed to withstand the demands of continuous water treatment systems\u003c\/li\u003e\n  \u003cli\u003eSupported by Water Softener Plus, a trusted vendor known for quality water treatment components\u003c\/li\u003e\n  \u003cli\u003eVersatile fit for multiple Fleck SXT models, reducing the need for multiple spare parts\u003c\/li\u003e\n  \u003cli\u003eDesigned to optimize system longevity and reduce maintenance costs over time\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ \u0026amp; Safety\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIs the FL90M-SXT-PH compatible with all Fleck control valves?\u003c\/strong\u003e\u003cbr\u003eThis power head is specifically designed for Fleck 90, 91, and 95 SXT models; it may not fit other valve types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow often should I perform maintenance on the power head?\u003c\/strong\u003e\u003cbr\u003eRegular system checks during routine water softener maintenance are sufficient; the power head itself requires minimal upkeep.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I install this power head myself?\u003c\/strong\u003e\u003cbr\u003eYes, with basic plumbing and electrical knowledge, following the step-by-step instructions carefully will ensure safe installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat operating conditions does the power head support?\u003c\/strong\u003e\u003cbr\u003eIt is designed to function reliably under typical residential and commercial water softening conditions, including standard temperature and pressure ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill this part improve water quality?\u003c\/strong\u003e\u003cbr\u003eWhile it doesn’t directly treat water, it ensures your Fleck valve operates efficiently, which is critical for maintaining optimal water treatment performance.\u003c\/p\u003e\n\n\u003cp\u003eUpgrade your system reliability today—add this component to your cart and keep your water flowing clean and consistent.\u003c\/p\u003e\u003c!--wsp-xsell-v1--\u003e\u003cdiv class=\"wsp-xsell\" style=\"margin-top:18px;\"\u003e\n\u003ch2\u003eComplete your system\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/filter-cartridges\"\u003eReplacement filters \u0026amp; cartridges\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/resins-filter-media-chemicals\"\u003eMedia \u0026amp; chemicals\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/collections\/control-valves-parts\"\u003eParts \u0026amp; accessories\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":44819860914229,"sku":"780851339086","price":940.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fl90m-sxt-ph-r1200.jpg?v=1789602027"},{"product_id":"fleck-motor-bracket-aux-switch","title":"Fleck Motor Bracket Aux Switch","description":"\u003cp\u003eThe Fleck motor bracket auxiliary switch is a genuine Pentair component used in Fleck control valve drive assemblies. This part combines two roles in a single piece, serving as the structural motor bracket while also incorporating an auxiliary switch function. Together these support both the secure mounting of the drive motor and the electrical signaling that helps coordinate the valve's operation throughout its regeneration cycle, making it a key part of a smoothly functioning control head.\u003c\/p\u003e\u003ch3\u003eDrive and Signal in One Part\u003c\/h3\u003e\u003cp\u003eA motor bracket holds the timer or drive motor in correct alignment so the gear train can advance the valve smoothly and quietly through each stage of its cycle. The integrated auxiliary switch provides position or status signaling to the control circuit, contributing to accurate timing and proper sequencing of the regeneration steps. Keeping this combined assembly in good condition helps ensure the valve transitions reliably from service into regeneration and back again without faults, hesitation, or the misalignment that can develop when a bracket is bent or worn.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGenuine Fleck\/Pentair replacement part\u003c\/li\u003e\n\u003cli\u003eFunction: motor bracket with integrated auxiliary switch\u003c\/li\u003e\n\u003cli\u003eSupports drive motor mounting and precise alignment\u003c\/li\u003e\n\u003cli\u003eAuxiliary switch aids valve position or status signaling\u003c\/li\u003e\n\u003cli\u003eHelps maintain reliable, accurate cycle transitions\u003c\/li\u003e\n\u003cli\u003eSuited to Fleck control valve drive assemblies\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIf your valve's drive system shows signs of misalignment, motor noise, or intermittent switching problems, inspecting the motor bracket and its auxiliary switch is a sensible early diagnostic step before replacing larger or costlier components. When ordering, confirm compatibility with your specific Fleck control valve so that both the bracket and switch fit and function correctly with your motor and gear train. Installing a genuine assembly restores smooth, dependable regeneration and helps protect the long-term reliability of your entire water-treatment system, keeping water properly softened or filtered cycle after cycle. Catching a worn or noisy drive assembly early, and replacing the bracket and switch as a unit, helps prevent the cascade of timing problems that can follow when the motor is allowed to run out of alignment for an extended period. Addressing drive-system issues promptly with the correct genuine assembly is the most reliable way to keep your softener or filter regenerating dependably for years to come.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668801282101,"sku":"FL11826-02","price":32.82,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-motor-bracket-aux-switch-hires-r1200.jpg?v=1789602658"},{"product_id":"fleck-shut-off-valve-cam","title":"Fleck Shut-Off Valve Cam","description":"\u003cp\u003eThe Fleck shut-off valve cam is a genuine Pentair part for the Fleck 2900S control valve, one of the brand's heavy-duty control heads designed for demanding residential and commercial applications. This cam is part of the mechanical system that governs flow control during the valve's operating cycle, translating drive motion into precise, repeatable movement of the shut-off components. On a high-capacity valve like the 2900S, accurate cam action is central to dependable, consistent performance day after day.\u003c\/p\u003e\u003cp\u003eA cam translates the rotation of the valve's drive into carefully timed movement of internal parts. The shut-off valve cam specifically helps control when and how flow is interrupted during the regeneration sequence, supporting the accurate, repeatable cycling that keeps your softener or filter performing exactly as intended. A worn, chipped, or damaged cam can throw off this timing, leading to incomplete cycles, premature shut-off, or shut-off that fails to occur at the right moment, all of which can affect treated water quality and system efficiency.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eDesigned for the Fleck 2900S control valve\u003c\/li\u003e\n\u003cli\u003eFunction: timing cam for shut-off valve operation\u003c\/li\u003e\n\u003cli\u003eGenuine Fleck\/Pentair replacement part\u003c\/li\u003e\n\u003cli\u003eSupports accurate flow control during the regeneration cycle\u003c\/li\u003e\n\u003cli\u003ePrecision component for reliable regeneration timing\u003c\/li\u003e\n\u003cli\u003eListed weight approximately 0.02 lbs per each\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eMaintaining Precise Cycling\u003c\/h3\u003e\u003cp\u003eIf your 2900S valve shows timing irregularities or shut-off problems, inspecting the cam for wear, cracking, or worn lobes is a worthwhile diagnostic step before suspecting larger components. Confirm that your valve is a 2900S before ordering so the cam matches your control head precisely, since cams from other valve models will not provide correct timing. Replacing a worn cam with a genuine Fleck part helps restore smooth, accurate, and dependable operation to this rugged valve, protecting both your equipment investment and the day-to-day consistency of your treated water. Pairing a new cam with fresh seals during a major service helps ensure the 2900S returns to crisp, factory-accurate cycling, protecting the heavy-duty performance this valve is known for in high-flow homes and commercial settings alike. A worn cam is inexpensive to replace yet costly to ignore, since timing faults left unaddressed can gradually undermine the reliability of an otherwise excellent control valve.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668801708085,"sku":"FL12777","price":56.22,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-shut-off-valve-cam-hires-r1200.jpg?v=1789602795"},{"product_id":"fleck-motor-lead-wire-pigtail","title":"Fleck Motor Lead Wire-Pigtail","description":"\u003cp\u003eThe FL14822 Fleck Motor Lead Wire (Pigtail) is a genuine Pentair electrical component that delivers power to the timer motor in a Fleck control valve. This pre-terminated wire harness connects the valve's motor to its power source, allowing the motor to drive the cam and gearing that step the valve through service and regeneration positions. Because it arrives ready-terminated, it provides a clean, code-correct connection without the need to improvise splices inside the valve.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOEM Fleck motor lead wire \/ pigtail harness\u003c\/li\u003e\n\u003cli\u003eSupplies power to the control-valve timer motor\u003c\/li\u003e\n\u003cli\u003ePre-terminated for straightforward replacement\u003c\/li\u003e\n\u003cli\u003eRestores reliable motor operation and cycling\u003c\/li\u003e\n\u003cli\u003eGenuine Pentair part built to factory specification\u003c\/li\u003e\n\u003cli\u003eEliminates makeshift wiring inside the valve\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eBecause the motor must run to advance every regeneration, a damaged, brittle, or corroded lead wire can leave a softener stuck in a single position, failing to recharge the resin and allowing hard water through to the home. The symptoms of a failing lead wire can mimic a failed motor, so checking the wiring first can save the cost and effort of an unnecessary motor replacement.\u003c\/p\u003e\u003cp\u003eDamp conditions around softener installations are notoriously hard on wiring; connectors can corrode, insulation can crack, and repeated handling during past service can fatigue the conductor. Swapping in a fresh OEM pigtail is a clean fix that avoids splicing temporary wiring into a control valve, which can introduce resistance, intermittent contact, or safety concerns. For installers and homeowners maintaining Fleck-equipped systems, using the correct factory lead wire ensures a proper, secure connection and keeps the valve cycling on schedule so the resin stays fully regenerated. Always disconnect power before servicing any electrical component on a control valve, and verify the connection is sound before restoring power and returning the unit to service.\u003c\/p\u003e\u003cp\u003eFor technicians on a service route, keeping a genuine pigtail on the truck means an electrical fault can be diagnosed and corrected in one visit rather than two. Because failed wiring so closely mimics a failed motor, swapping in a known-good lead wire is also a useful diagnostic step that can save the cost of an unnecessary motor. A sound, factory-correct connection is the foundation of reliable, on-schedule cycling for any Fleck-equipped softener.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668803117109,"sku":"FL14822","price":79.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-motor-lead-wire-pigtail-hires-r1200.jpg?v=1789602667"},{"product_id":"fleck-motor-24v-50-60-1-rpm-90-91-se","title":"Fleck Motor, 24v, 50\/60 1 Rpm, 90\/91 Se","description":"\u003cp\u003eThis genuine Fleck timer motor is a 24-volt, 1 RPM drive motor rated for 50\/60 Hz operation, designed for the 90\/91 SE series and listed under valve model 9500. As one of the small but essential drive components in a Pentair Fleck control valve, the motor turns the cam and gear train that advances the valve through its regeneration positions on the programmed schedule. When it runs smoothly, the valve indexes cleanly from service to backwash, brine draw, slow rinse, and refill; when it stalls, the cycle simply stops.\u003c\/p\u003e\u003ch3\u003eWhere this motor fits\u003c\/h3\u003e\u003cp\u003eThe 24V supply and 1 RPM output make this a direct service replacement where the original low-voltage SE-series timer motor has stalled, hummed without turning, or stopped advancing the regeneration cycle. Matching the correct voltage and RPM is critical: installing a mismatched motor will cause incorrect cycle timing, incomplete regeneration, and poor softening or filtration results. This motor pairs with control heads fed by a low-voltage transformer rather than direct line power.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage: 24V, compatible with 50\/60 Hz systems\u003c\/li\u003e\n\u003cli\u003eOutput speed: 1 RPM for proper cam advancement and cycle timing\u003c\/li\u003e\n\u003cli\u003eEngineered for the 90\/91 SE series, listed under valve model 9500\u003c\/li\u003e\n\u003cli\u003eGenuine Pentair Fleck replacement part for a precise, factory-spec fit\u003c\/li\u003e\n\u003cli\u003eLightweight at roughly 0.26 lbs, allowing simple bolt-in service\u003c\/li\u003e\n\u003cli\u003eRestores dependable, scheduled regeneration on SE-series controls\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eA drive motor that fails to rotate is one of the most common reasons a softener stops regenerating, leaving the resin bed exhausted and hard water passing through to the home. Telltale symptoms include a control head stuck in one position, audible buzzing with no movement, or a cycle that never completes. Because the motor is inexpensive relative to the disruption a failed regeneration causes, many installers keep a spare on hand.\u003c\/p\u003e\u003cp\u003eBefore replacing, confirm power is reaching the motor and that the cam and gears spin freely by hand, since binding elsewhere in the drive can imitate a dead motor. Always unplug the controller and place the valve in bypass before disconnecting the old motor and wiring in the new one. With the correct 24V SE motor installed, your Fleck 9500-series valve returns to quiet, reliable, on-schedule regeneration.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668806983733,"sku":"FL18737","price":259.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-motor-24v-50-60-1-rpm-90-91-se-hires-r1200.jpg?v=1789602639"},{"product_id":"fleck-motor-120-volt-1-rpm-50-60-hz","title":"Fleck Motor, 120 Volt 1 Rpm 50\/60 Hz.","description":"\u003cp\u003eKeep your Fleck control valve cycling on schedule with this genuine Pentair Fleck drive motor, supplied at 120 volts with a 1 RPM output and rated for 50\/60 Hz service. Listed under valve model 9500, it is the timer-drive motor responsible for rotating the cam stack that steps the valve through service and regeneration positions. Each turn of this motor is what carries the valve from backwash to brine draw to rinse and refill, so its steady rotation is fundamental to proper treatment.\u003c\/p\u003e\u003cp\u003eThis is the standard line-voltage version of the Fleck timer motor, making it the right choice when your softener or filter wires directly to household 120V power rather than a low-voltage transformer. Confirming both the voltage and the 1 RPM speed is essential, since an incorrect motor will throw off cycle timing and can leave the valve stuck or under-regenerating.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e120-volt operation for direct line-power control heads\u003c\/li\u003e\n\u003cli\u003e1 RPM output speed, 50\/60 Hz compatible\u003c\/li\u003e\n\u003cli\u003eGenuine Fleck component listed for valve model 9500\u003c\/li\u003e\n\u003cli\u003eCompact 0.26 lb service part for straightforward replacement\u003c\/li\u003e\n\u003cli\u003eRestores reliable, programmed regeneration cycling\u003c\/li\u003e\n\u003cli\u003eDrop-in fit using the original mounting and wiring connections\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eRecognizing a failed timer motor\u003c\/h3\u003e\u003cp\u003eWhen a drive motor wears out, the most telltale sign is a valve that no longer advances: it may sit locked in backwash or brine draw, or hum quietly without turning. The downstream effect is hard or untreated water reaching the home because the resin or media never regenerates. A motor can also fail intermittently, regenerating some days and not others, which makes the symptom harder to pin down.\u003c\/p\u003e\u003cp\u003eVerify that the cam and gear train rotate freely and that voltage is present at the motor leads before swapping the part, ruling out a binding cam or wiring fault. Always disconnect power and place the valve in bypass first, then transfer the wiring to the new motor exactly as it came off. Installing this matched 120V, 1 RPM motor returns your Fleck 9500-series control to smooth, dependable operation and protects the rest of the household plumbing from the effects of untreated hard water. Keeping a spare line-voltage motor on hand is good practice, since a quick swap restores regeneration and spares the household the inconvenience of hard water while you wait for a part to arrive.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668807245877,"sku":"FL18738","price":259.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-motor-120-volt-1-rpm-50-60-hz-hires-r1200.jpg?v=1789602630"},{"product_id":"fleck-drive-motor-220v-sp","title":"Fleck Drive Motor, 220v, SP","description":"\u003cp\u003eThis genuine Fleck drive motor is the 220-volt, 50\/60 Hz, single-phase (SP) version used on the Fleck 3900 control valve. The 3900 is a high-capacity valve aimed at larger residential and commercial systems, and its drive motor powers the cam and gear train that move the valve through service and the multiple regeneration stages. On a valve of this size, dependable drive operation is essential to keeping a substantial volume of treated water flowing.\u003c\/p\u003e\u003cp\u003eThe 220V single-phase specification is important: this motor is intended for installations wired to 220V power, so always match your control head's voltage before installing. Using the correct motor ensures proper cycle timing and full regeneration on these higher-flow valves, while a voltage mismatch will disrupt timing and can damage the motor.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e220-volt, 50\/60 Hz, single-phase Fleck drive motor\u003c\/li\u003e\n\u003cli\u003eEngineered for the high-capacity Fleck 3900 control valve\u003c\/li\u003e\n\u003cli\u003eDrives the cam and gear train for accurate cycle indexing\u003c\/li\u003e\n\u003cli\u003eGenuine Pentair Fleck replacement part, about 1.0 lb\u003c\/li\u003e\n\u003cli\u003eRestores reliable regeneration on large-flow systems\u003c\/li\u003e\n\u003cli\u003eDirect replacement using the original mounting points\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eServicing a 3900 drive\u003c\/h3\u003e\u003cp\u003eBecause the 3900 often handles demanding duty in commercial and high-flow residential applications, a stalled drive motor can take a sizable softening or filtration system offline, allowing untreated water through to processes, fixtures, or equipment that depend on conditioned water. The cost of that downtime usually dwarfs the cost of the motor, which is why keeping the drive in good order is a priority on these systems.\u003c\/p\u003e\u003cp\u003eTypical failure signs include a valve stuck mid-cycle, audible humming with no rotation, or incomplete regeneration that leaves softness or filtration performance steadily declining. Before replacing, verify that the cam and gears turn freely by hand and that the correct voltage is present at the motor leads, since binding elsewhere in the drive can imitate a failed motor. Disconnect power and place the valve in bypass before service. With the matched 220V single-phase motor installed, your Fleck 3900 returns to steady, dependable operation. Keeping a spare 220V single-phase motor on hand is sensible for commercial sites, where the cost of a brief swap is trivial compared with the downtime a stalled high-capacity valve can cause.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668808327221,"sku":"FL40389","price":234.25,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-drive-motor-220v-sp-hires-r1200.jpg?v=1789602492"},{"product_id":"fleck-wire-harness-upper-drive","title":"Fleck Wire Harness, Upper Drive","description":"\u003cp\u003eThe Fleck Upper Drive Wire Harness (FL40941) is the wiring assembly that feeds power and signals to the upper-drive section of multi-drive Fleck control valves. On valves that use separate upper and lower drive assemblies, dependable upper-drive wiring is essential for coordinated, accurate cycling through regeneration. When the two drives must work in concert, the integrity of each harness directly affects the whole sequence.\u003c\/p\u003e\u003cp\u003eThis is a genuine Pentair Fleck component. Whenever you service the drive end of a valve, refreshing aged wiring helps eliminate the intermittent faults that brittle or corroded harnesses can cause, and it ensures the rebuilt control behaves predictably for years to come.\u003c\/p\u003e\u003ch3\u003eComponent overview\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eUpper-drive wire harness for Fleck control valves\u003c\/li\u003e\n\u003cli\u003eDelivers power and control signals to the upper drive assembly\u003c\/li\u003e\n\u003cli\u003eGenuine Pentair Fleck replacement part\u003c\/li\u003e\n\u003cli\u003eHelps ensure reliable, coordinated cycle operation\u003c\/li\u003e\n\u003cli\u003eA smart item to inspect during any drive-end rebuild\u003c\/li\u003e\n\u003cli\u003eResolves erratic behavior traced to degraded wiring\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eWiring problems are easy to overlook but can be the true source of frustrating, hard-to-diagnose softener behavior: a valve that advances inconsistently, stalls partway through a cycle, or shows erratic timer readings that come and go. Because these faults are intermittent, they often lead to unnecessary replacement of motors or boards before the wiring is finally suspected. On larger multi-drive Fleck valves, the upper and lower drives must work in synchrony, so a degraded upper harness can throw off the entire regeneration sequence rather than just one stage.\u003c\/p\u003e\u003cp\u003eWhen you have the control open for other repairs, check the harness for cracked insulation, loose or corroded pins, and signs of heat or chafing, and replace it if there is any doubt. A new harness is inexpensive relative to the diagnostic time a failing one can consume. Always disconnect power before working on the wiring, transfer the connections carefully so nothing is reversed, and route the new harness clear of moving cam and gear parts to prevent future chafing and a repeat failure. A fresh, properly routed upper harness gives you confidence that the wiring is no longer a suspect the next time you troubleshoot the valve, letting you focus on mechanical components if a problem ever recurs.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668808589365,"sku":"FL40941","price":71.51,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-wire-harness-upper-drive-hires-r1200.jpg?v=1789602869"},{"product_id":"fleck-wire-harness-lower-drive","title":"Fleck Wire Harness, Lower Drive","description":"\u003cp\u003eThe Fleck Lower Drive Wire Harness with strain relief (FL40943) is the wiring assembly serving the lower-drive section of the Fleck 3200NT and related multi-drive valves. Its integrated strain relief protects the connection points from vibration and pull-through, helping the harness survive years of mechanical cycling without fatiguing at the terminals where wiring failures most often begin.\u003c\/p\u003e\u003cp\u003eAs a genuine Pentair Fleck part, it restores clean electrical connections to the lower drive so the valve indexes and regenerates as designed. Replacing tired wiring during a rebuild is an easy, inexpensive way to prevent intermittent, hard-to-trace faults from cropping up later.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eLower-drive wire harness for the Fleck 3200NT and similar valves\u003c\/li\u003e\n\u003cli\u003eBuilt-in strain relief guards against vibration and pull-out\u003c\/li\u003e\n\u003cli\u003eCarries power and signals to the lower drive assembly\u003c\/li\u003e\n\u003cli\u003eGenuine Pentair Fleck replacement component\u003c\/li\u003e\n\u003cli\u003eGood preventive replacement during drive-end service\u003c\/li\u003e\n\u003cli\u003eResists fatigue at the connection points\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eDiagnosing wiring faults\u003c\/h3\u003e\u003cp\u003eOn multi-drive valves like the 3200NT, the lower drive coordinates with the upper to step the valve through its cycle, so a degraded lower harness can disrupt the whole regeneration sequence rather than just one position. The result can be a stalled valve, erratic timing, or operation that works one day and fails the next. These symptoms frequently masquerade as motor or board failures, so checking the wiring first can save the time and expense of swapping parts that were never the problem.\u003c\/p\u003e\u003cp\u003eThe strain relief on this harness is particularly valuable: most wiring failures occur where conductors flex or bear load at the connectors, and the strain relief takes that stress off the delicate junctions. That is why a harness with proper strain relief tends to outlast a makeshift repair.\u003c\/p\u003e\u003cp\u003eWhen servicing, inspect for cracked insulation, corrosion, loose terminals, or any sign of heat, and replace the harness if anything looks marginal. Always disconnect power before working on the wiring, and route the new harness away from the moving cam and gear components so it cannot chafe and fail again. Replacing the lower harness during a rebuild is cheap insurance against the kind of intermittent, hard-to-chase faults that can otherwise turn a simple service call into hours of frustrating diagnosis.\u003c\/p\u003e\u003c!--rel-sys-v1--\u003e\u003cdiv class=\"related-systems\"\u003e\n\u003ch3\u003eRelated Systems \u0026amp; Configurations\u003c\/h3\u003e\n\u003cp\u003eComparing options? These related commercial water-treatment systems are frequently viewed alongside this one:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fleck-wire-harness-upper-drive\"\u003eFleck Wire Harness, Upper Drive\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fleck-wire-harness-kit-dc-2815\"\u003eFleck Wire Harness Kit, DC, 2815\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fleck-drive-pinion\"\u003eFleck Drive Pinion (3150)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/fleck-drive-mtr-230v\"\u003eFleck Drive Mtr, 230v\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668808622133,"sku":"FL40943","price":84.91,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-wire-harness-lower-drive-hires-r1200.jpg?v=1789602860"},{"product_id":"fleck-timer-assy-3200-3214-rigt-hing","title":"Fleck Timer Assy, 3200\/3214 Rigt Hing","description":"\u003cp\u003eThe Fleck Timer Assembly for 3200\/3214 valves, right-hinge configuration (FL42466-11), is a complete NXT-series timer module that controls regeneration on these Fleck valves. As the electronic brain of the control head, the NXT timer manages the cycle schedule, monitors flow when the valve is metered, and signals the drive to step the valve through service and regeneration. When it is healthy, the whole valve runs predictably; when it fails, even a mechanically perfect valve sits idle.\u003c\/p\u003e\u003cp\u003eThis right-hinge version is built to mount and open correctly for a specific control-head orientation, so matching the hinge direction to your existing assembly ensures proper fit, clearance, and access for wiring and service. It is a genuine Pentair Fleck NXT timer component.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eComplete NXT-series timer assembly for Fleck 3200\/3214 valves\u003c\/li\u003e\n\u003cli\u003eRight-hinge configuration for correct mounting and access\u003c\/li\u003e\n\u003cli\u003eManages regeneration scheduling and drive control\u003c\/li\u003e\n\u003cli\u003eGenuine Pentair Fleck replacement module, about 0.64 lbs\u003c\/li\u003e\n\u003cli\u003eRestores full programmability to the control head\u003c\/li\u003e\n\u003cli\u003eSupports both metered and time-clock operation as configured\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eWhen a timer needs replacing\u003c\/h3\u003e\u003cp\u003eThe NXT timer is a sophisticated electronic assembly, and when it fails the symptoms can include a blank or frozen display, lost programming that won't hold, a valve that won't initiate regeneration, or erratic cycling that has no obvious pattern. Because it coordinates the entire regeneration process, a faulty timer effectively disables the softener or filter even when the mechanical drive, piston, and seals are all sound.\u003c\/p\u003e\u003cp\u003eBefore replacing, confirm power is reaching the unit and rule out a failed transformer, a loose connector, or a wiring fault, since these can imitate a dead timer and lead to an unnecessary swap. Once you have confirmed the timer itself is the problem, the replacement is straightforward.\u003c\/p\u003e\u003cp\u003eWhen installing the new right-hinge assembly, mount it squarely so it seats and closes properly, connect the drive and meter leads carefully in their correct positions, and then reprogram the regeneration settings to match your water hardness and household or facility usage. Always disconnect power before swapping the timer module, and double-check the programming once power is restored so the valve regenerates exactly as intended. Stocking a spare NXT timer matched to your hinge orientation lets you restore a down valve quickly, since the electronic control is the one component that can idle an otherwise perfectly sound mechanical valve.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668809146421,"sku":"FL42466-11","price":624.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-timer-assy-3200-3214-rigt-hing-hires-r1200.jpg?v=1789602841"},{"product_id":"fleck-cam-rapid-rinse","title":"Fleck Cam, Rapid Rinse","description":"\u003cp\u003eKeep your Fleck control valve cycling on schedule with the genuine Pentair Fleck Cam, Rapid Rinse. The cam is the timing element that the valve's drive system rotates to advance through each stage of the regeneration sequence. In a mechanically timed Fleck head, the shape of the cam's lobes determines exactly when each microswitch trips and how long the piston dwells in a given position. The rapid rinse cam specifically governs the fast-rinse step that flushes the resin bed after brine has been drawn.\u003c\/p\u003e\u003ch3\u003eThe Role of the Rapid Rinse Step\u003c\/h3\u003e\u003cp\u003eDuring regeneration, a water softener or filter pushes a high flow of water down through the media to settle the resin bed, rinse away residual brine, and prepare the resin for the next service run. If this step is too short, salty water and leftover brine remain in the tank; if it is mistimed, the bed may not be properly conditioned. The rapid rinse cam ensures this stage opens and closes at precisely the right point in the cycle, so the bed is rinsed thoroughly without wasting water or salt.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGenuine Pentair Fleck replacement cam\u003c\/li\u003e\n\u003cli\u003eControls the rapid rinse stage of the regeneration cycle\u003c\/li\u003e\n\u003cli\u003eDirect-fit timing component for compatible Fleck valves\u003c\/li\u003e\n\u003cli\u003eRestores accurate cycle sequencing in aging control heads\u003c\/li\u003e\n\u003cli\u003eHelps prevent salty water and incomplete rinses\u003c\/li\u003e\n\u003cli\u003eSimple, low-cost service part for routine maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003eIf your softener has started producing salty-tasting water, skipping the rinse stage, or otherwise running through its cycle out of sequence, a worn, cracked, or chipped cam is a common culprit. Plastic cams can wear at the lobe edges over thousands of cycles, gradually throwing off the timing the valve depends on. Swapping in a fresh Rapid Rinse cam is a quick, inexpensive fix that brings the valve's timing back to specification. This part is a popular service item for installers maintaining residential and light-commercial Fleck systems across the country. Always disconnect power and follow the documented timing procedure when reassembling so the cam indexes correctly to the valve. Because cams are inexpensive relative to the cost of a service call or a return of hard water, many homeowners and technicians keep the common timing cams on the shelf so a worn part never sidelines the system for long.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668810686517,"sku":"FL60160-00","price":51.96,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-cam-rapid-rinse-hires-r1200.jpg?v=1789602437"},{"product_id":"fleck-drive-cam","title":"Fleck Drive Cam, Separate Time Fill","description":"\u003cp\u003eThis genuine Pentair Fleck Drive Cam is the timing cam used in the Fleck 2850S control valve. As the valve's drive motor turns, the drive cam rotates and its lobes trip the internal microswitches that advance the piston through service, backwash, brine draw, slow rinse, and fast rinse positions on a precise, repeatable schedule. Without an accurately shaped cam, the valve cannot keep proper time, and the entire regeneration sequence falls out of step.\u003c\/p\u003e\u003cp\u003eAt just 0.06 lb, the drive cam is a small but absolutely critical part. If it cracks, strips a tooth, or wears down at the lobes after years of cycling, the valve may stall mid-cycle, skip a regeneration stage, fail to return to service, or hold in one position far too long. Any of these faults can leave you with hard water, wasted salt, or a valve that simply stops working. Replacing the cam restores correct, consistent timing to the 2850S head.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eGenuine Fleck 2850S drive cam\u003c\/li\u003e\n\u003cli\u003eSynchronizes valve cycle positions with the drive motor\u003c\/li\u003e\n\u003cli\u003eTrips the internal microswitches in correct sequence\u003c\/li\u003e\n\u003cli\u003eDirect replacement for worn, cracked, or stripped cams\u003c\/li\u003e\n\u003cli\u003eRestores reliable regeneration sequencing\u003c\/li\u003e\n\u003cli\u003eCompact, lightweight service component\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eA Workhorse Valve Platform\u003c\/h3\u003e\u003cp\u003eThe Fleck 2850S is widely used on larger residential and commercial softeners and filters where higher flow rates and capacity are required, so keeping the drive cam in good condition is essential to system uptime. Installers often replace the cam alongside the drive motor, gears, and microswitches during a full control-head service, since these timing components tend to wear together. Always disconnect power before opening the cover, and follow Pentair's documented timing and indexing procedure when reassembling so the cam aligns correctly with the piston position. Doing so ensures every stage of the cycle begins and ends exactly where it should. Because the cam coordinates the mechanical drive with the electrical microswitches, even slight wear at a single lobe can ripple through the entire cycle and produce symptoms that seem unrelated to timing at first glance, so inspecting it during any control-head service is good practice. A correctly indexed drive cam is the foundation of every reliable regeneration, which is why technicians treat it as a key checkpoint when restoring an older 2850S to dependable, set-and-forget operation.\u003c\/p\u003e","brand":"Fleck","offers":[{"title":"Default Title","offer_id":45668810752053,"sku":"FL60160-40","price":93.32,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0552\/4950\/2261\/files\/fleck-drive-cam-hires-r1200.jpg?v=1789602483"}],"url":"https:\/\/checkout.watersoftenerplus.com\/collections\/fleck-valve-motors-timers-and-drives.oembed","provider":"Water Softener Plus","version":"1.0","type":"link"}